What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 4 scope lines.
A2LA certificate 3623.12 · 4 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3623.12) 10/08/2025 Page 1 of 3
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
HERBALIFE
3200 Temple School Road
Winston Salem, NC 27107
Wendy Bigala Phone: 336 970-3020
CALIBRATION
Valid To: September 30, 2027 Certificate Number: 3623.12
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations1, 4:
I. Mechanical
Parameter/Equipment
Range
CMC2 (±)
Comments
Balances3
(1 to 500) mg
(1 to 50) g
(100 to 200) g
(500 to 1000) g
(1000 to 1500) g
0.18 mg
0.0013 g
0.0054 g
0.0037 g
0.0042 g
Class 1 weights
Scales3
(1 to 10) kg
0.18 g
Class F weights
II. Thermodymanics
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
Temperature – Measuring
Equipment
Data Loggers
(0 to <10) °C
(10 to <25) °C
(25 to <50) °C
(50 to <70) °C
70 °C
0.06 °C
0.09 °C
0.08 °C
0.08 °C
0.13 °C
Thunder Scientific
series 2500 | ||
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3623.12) 10/08/2025 Page 2 of 3
Parameter/Equipment
Range
CMC2, 3 (±)
Comments
Temperature – Measuring
Equipment (cont)
Data Loggers, Portable
Digital and Glass
Liquid Filled
Thermometers, Chart
Recorders
Portable Digital and
Glass Liquid Filled
Thermometers
(-35 to 140) °C
(33 to 350) °C
0.17°C
0.11 °C
Fluke 9170
Fluke 9143
Temperature – Measure
Refrigerators,
Incubators, Ovens
Ovens
Freezers
(-40 to 0) °C
(0 to 35) °C
(35 to 40) °C
(35 to 85) °C
(85 to 140) °C
(50 to 200) °C
(200 to 400) °C
-80 °C
0.48 °C
0.048 °C
0.082 °C
0.060 °C
0.13 °C
1.9 °C
2.2 °C
2.5 °C
HiTemp 140 data
loggers
Temp2000A RTD data
logger
Humidity – Measuring
Equipment
(10 to 50) % RH
(50 to 80) % RH
0.51 % RH
0.63 % RH
Thunder Scientific
series 2500
Environmental Chambers3
(11 to 80) % RH
(25 to 75) °C
1.5 % RH
0.5 °C
Vaisala data logger
_________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMC’s
represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using
a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by
the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences
from the circumstances of the specific calibration. | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3623.12) 10/08/2025 Page 3 of 3
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects suc h as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 4 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.