Registers refreshed 2026-11-08.See refresh dates
United States

Pi Tape Texas

10235 Robinson Dr, 75703-3416, Tyler, TX, United States

Visit website
A2LA 7417.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
5
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 5 scope lines.

A2LA certificate 7417.01 · 5 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7417.01) Revised 07/28/2025 Page 1 of 4 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 PI TAPE TEXAS, LLC 10235 Robinson Dr Tyler, TX 75703-3416 Harold “Skip” Phillips Phone: (903) 266-9204 CALIBRATION Valid To: March 31, 2027 Certificate Number: 7417.01 In recognition of the successful co mpletion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 4: I. Dimensional Parameter/Equipment Range CMC 2, 5 (±) Comments Length Up to 67 858 mm Up to 2714 in (0.96 + 0.000 47L) µm (37 + 0.47L) µin Laser measurement system Master Tapes (Diameter) Up to 75 in Up to 1905 mm (10 + 0.77L) µin (0.26 + 0.000 77L) µm Laser measurement system Cylindrical Gages Up to 75 in Up to 1905 mm (280 + 0.39L) µin (7.2 + 0.000 39L) µm Master tapes & Laser system Linear Vernier Scales Up to 10 mm (Up to 25 in) Up to 10 mm (Up to 25 in) 23 µm 780 µin 7.7 µm 300 µin Optical comparator Laser measurement system
to 67858 mm
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7417.01) Revised 07/28/2025 Page 2 of 4 Parameter/Equipment Range CMC2, 5 (±) Comments Linear Machines Marked for Diameter Measurements Up to 72 in Up to 2000 mm Up to 72 in Up to 2000 mm (81 + 0.62L) µin (0.45 + 0.000 62L) µm (14 + 0.35L) µin (0.34 + 0.000 37L) µm Gage blocks (backup method) Laser measurement system Linear Machines Marked for Linear Measurements Up to 192 in Up to 5000 mm Up to 192 in Up to 5000 mm (63 + 0.88L) µin (1.0 + 0.000 68L) µm (47 + 0.33L) µin (1.0 + 0.000 38L) µm Gage blocks (backup method) Laser measurement system Precision Diameter Tapes Digital Diameter Tapes R = 0.0005 in R = 0.01 mm Go/No Go Diameter Tapes Outside, Inside, Belt, O-Ring & Wide Diameter Tapes O.D. & I.D. Vernier = 25 in R = 0.001 in Vernier = 50 mm R = 0.01 mm Vernier = Up to 10 in R = 0.001 in Vernier = Up to 25 mm R = 0.01 mm Up to 75 in Up to 1905 mm Up to 75 in Up to 1368 in Up to 1905 mm Up to 34 200 mm Up to 75 in Up to 1905 mm Up to 1368 in Up to 34 200 mm Up to 75 in Up to 1368 in Up to 1905 mm Up to 34 200 mm Up to 75 in Up to 1905 mm (430 + 0.78L) µin (11 + 0.000 78L) µm (380 + 0.78L) µin (120 + 0.14L) µin (9.5 + 0.000 46L) µm (2.6 + 0.000 15L) µm (360 + 0.78L) µin (9.0 + 0.000 78L) µm (61 + 0.2L) µin (1.5 + 0.000 21L) µm (430 + 0.39L) µin (240 + 0.11L) µin (9.5 + 0.000 46L) µm (2.7 + 0.000 18L) µm (430 + 0.39L ) µin (9.5 + 0.000 46L) µm Cylindrical gages (or optical comparator) Cylindrical gages Linear machine Cylindrical gages Linear machine Cylindrical gages (or optical comparator) Linear machine Cylindrical gages Linear machine Cylindrical gages Linear machine Cylindrical gages Cylindrical gages
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7417.01) Revised 07/28/2025 Page 3 of 4 Parameter/Equipment Range CMC2, 5 (±) Comments Precision Diameter Tapes (cont.) Outside, Inside, Belt, O-Ring & Wide Diameter Tapes O.D. & I.D. Vernier = Up to 10 mm R = 0.05 mm Vernier = 100 in R = 0.01 in Vernier = 25 mm R = 0.5 mm Up to 1905 mm Up to 75 in Up to 1368 in Up to 1905 mm Up to 34 200 mm 15 µm 0.0023 in 0.0023 in 120 µm 120 µm Cylindrical gages Cylindrical gages Linear machine Cylindrical gages Linear machine Precision Linear Measurement Tapes Digital Linear Tapes R = 0.0005 in R = 0.01 mm Linear Tapes Vernier = 25 in R = 0.001 in Vernier = 10 mm R = 0.1 mm Up to 444 in Up to 11 278 mm Up to 1200 in Up to 48 000 mm Up to 1200 in Up to 48 000 mm (350 + 4.8L) µin (19 + 0.0056L) µm (180 + 0.38L) µin (4.6 + 0.000 31L) µm (260 + 0.34L) µin (23 + 0.000 15L) µm Linear machine Gage blocks (or optical comparator) Linear machine calibrated with laser measurement system Linear machine calibrated with laser measurement system Precision Circumference Tapes Digital Circumference Tapes R = 0.0005 in R = 0.01 mm Outside & Inside Circumference Tapes Vernier = 25 in R = 0.001 in Vernier = 10 mm R = 0.1 mm Up to 444 in Up to 11 278 mm Up to 235 in Up to 1200 in Up to 6000 mm Up to 48 000 mm Up to 235 in Up to 1200 in Up to 6000 mm Up to 48 000 mm (350 + 4.8L) µin (19 + 0.0056L) µm 1200 µin (180 + 0.38L) µin (29 + 0.000 49L) µm (4.6 + 0.000 31L) µm 1200 µin (260 + 0.34L) µin (37 + 0.000 49L) µm (23 + 0.000 15L) µm Linear machine, gage blocks, cylindrical gages Cylindrical gages Linear machine Cylindrical gages Linear machine Cylindrical gages Linear machine Cylindrical gages Linear machine
to 11278 mm
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7417.01) Revised 07/28/2025 Page 4 of 4 __________________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the small est uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 This scope meets A2LA’s P112 Flexible Scope Policy. 5 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches or mm.
5ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

10235 Robinson Dr, Tyler, TX, 75703-3416, US

32.35126, -95.30106

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.