- A2LARefreshed
- 1266.03Active
Certificates and scope
1ISO/IEC 17025
Active1266.03
The scope document we hold says it is valid until 2027-01-31.
Accredited scope, certificate 1266.03
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | electrical | 47 CFR FCC Part 15, Subpart B; ANSI C63.4:2014; 47 CFR FCC Part 18; FCC OST/MP-5 (1986); ICES-001; ICES-003; CISPR 11; EN 55011; SANS 211; CISPR 13; EN 55013; CISPR 15; EN 55015; EN IEC 55015; SANS 215; CISPR 22; EN 55022; CISPR 32; EN 55032; AS/NZS CISPR 32; SANS 2332; IEC 61000-6-3; EN 61000-6-3; EN IEC 61000-6-3; SANS 61000-6-3; IEC 61000-6-4; EN 61000-6-4; EN IEC 61000-6-4; SANS 61000-6-4; VCCI-CISPR32; IEC 61000-3-2; EN 61000-3-2; EN IEC 61000-3-2; SANS 61000-3-2; IEC 61000-3-3; EN 61000-3-3; SANS 61000-3-3; IEC 61000-4-2; EN 61000-4-2; SANS 61000-4-2; IEC 61000-4-3; EN 61000-4-3; EN IEC 61000-4-3; SANS 61000-4-3; IEC 61000-4-4; EN 61000-4-4; SANS 61000-4-4; IEC 61000-4-5; EN 61000-4-5; SANS 61000-4-5; IEC 61000-4-6; EN 61000-4-6; EN IEC 61000-4-6; SANS 61000-4-6 | Medical equipment, electrical safety and EMC | to 40 GHz |
| 2 | electrical | IEC 61000-4-8; EN 61000-4-8; SANS 61000-4-8; IEC 61000-4-11; EN 61000-4-11; EN IEC 61000-4-11; SANS 61000-4-11; IEC 61000-4-39; EN 61000-4-39; CISPR 20; EN 55020; CISPR 24; EN 55024; CISPR 35; EN 55035; SANS 2335; IEC 61547; EN 61547; SANS 61547; IEC 61000-6-1; EN 61000-6-1; EN IEC 61000-6-1; SANS 61000-6-1; IEC 61000-6-2; EN 61000-6-2; EN IEC 61000-6-2; SANS 61000-6-2; IEC 61131-2; EN 61131-2; SANS 61131-2; EN 50270; EN 50130-4; IEC 61326-1; EN 61326-1; EN IEC 61326-1; SANS 61326-1; IEC 61326-2-1; EN 61326-2-1; EN IEC 61326-2-1; IEC 61326-2-2; EN 61326-2-2; EN IEC 61326-2-2; IEC 61326-2-3; EN 61326-2-3; EN IEC 61326-2-3; SANS 61326-2-3; IEC 61326-2-6; EN 61326-2-6; EN IEC 61326-2-6; IEC 60601-1-2; EN 60601-1-2; SANS 60601-1-2; ANSI C63.4; ANSI C63.10:2013; ANSI C63.10:2020; ANSI C63.26; ANSI/TIA-603E; ASTM E2213-03; ANSI/TIA-102.CAAA-E; FCC KDB 905462 D02v02; CFR 47 FCC Part 15 Subpart C; CFR 47 FCC Part 15 Subpart E; CFR 47 FCC Part 15 Subpart F; CFR 47 FCC Part 22; CFR 47 FCC Part 24; CFR 47 FCC Part 25; CFR 47 FCC Part 27; CFR 47 FCC Part 30; CFR 47 FCC Part 73; CFR 47 FCC Part 74; CFR 47 FCC Part 80; CFR 47 FCC Part 87; CFR 47 FCC Part 90; CFR 47 FCC Part 95; CFR 47 FCC Part 97; CFR 47 FCC Part 101; RSS-GEN; RSS-119; RSS-132; RSS-133; RSS-141; RSS-210; RSS-216; RSS-220; RSS-238; RSS-247; RSS-248; RSS-310 | - | to 26 MHz |
| 3 | electrical | ETSI EN 300 220-1; ETSI EN 300 220-2; ETSI EN 300 220-3-1; ETSI EN 300 220-3-2; ETSI EN 300 220-4; ETIS EN 300 330; ETSI EN 300 328; ETSI EN 300 440; ETSI EN 301 893; ETSI EN 302 208; ETSI EN 302 571; ETSI EN 303 417; ETSI EN 302 065-1; ETSI EN 302 065-2; ETSI EN 302 065-3; ETSI EN 302 065-3-1; ETSI EN 303 413; ETSI EN 303 883; ETSI EN 301 441; ETSI EN 303 345-1; ETSI EN 303 345-2; ETSI EN 303 345-3; ETSI EN 303 345-4; ETSI EN 303 687; ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-5; ETSI EN 301 489-17; ETSI EN 301 489-19; ETSI EN 301 489-20; ETSI EN 301 489-33; AS/NZS AS/NZS 4268; IEEE std. 1528; IEC 62311; EN 62311; EN IEC 62311; IEC 62209-1; EN 62209-1; IEC 62209-2; EN 62209-2; IEC/IEEE 62209-1528; EN IEC/IEEE 62209-1528; IEC/IEEE 63195-1; EN IEC/IEEE 63195-1; IEC PAS 63446; AS/NZS TS IEC 63446; KDB 865664; RSS-102; RSS-102.SAR.MEAS; RSS-102.NS.MEAS; Radiocommunications Equipment (General) Rules 2021 Part 4 Schedule 4; ARPANSA Standard Means the Radiation Protection Standard for Limiting Exposure to Radiofrequency Fields – 100 kHz to 300 GHz; EN 50360; EN 50566; ISO 7637-2 | - | - |
| 4 | electrical | ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2013; FCC KDB 905462 D02 (v02); ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C63.26:2015 | - | to 40000 MHz |
| 5 | electrical | ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C63.26:2015; IEEE Std 1528:2013; IEC 60601-1-2 Edition 4.1 2020-09 CONSOLIDATED VERSION | - | to 40000 MHz |
| 6 | electrical | - | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
1-22-3 Megumigaoka, Hiratsuka-shi, Kanagawa, 259-1220, Japan, Kanagawa, JP
35.43429, 139.37475
Open in MapsLabs with overlapping accredited scope in Japan
- UL JapanIse-shi, Mie · ~263 kmA2LAShares 3 accredited methods and materialsANSI C63.4:2014ANSI/TIA-603-EMedical equipment, electrical safety and EMC
- TUV SUD Japan Ltd. Yonezawa Testing Center (EMC Lab)Yamagata · ~344 kmA2LAShares 2 accredited test methodsANSI C63.4:2014ANSI/TIA-603-E
- TUV SUD JapanTokyo · ~44 kmA2LAShares 1 accredited materialMedical equipment, electrical safety and EMC
- UL Japan, Inc. - Kashima EMCChiba-ken, 289-0341 · ~66 kmA2LAShares 1 accredited test methodIEC 61000-4-8
- QSES Inc. Testing LaboratoryAbiko-Shi, Chiba · ~76 kmA2LAShares 1 accredited test methodIEC 61000-4-8
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.