FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
United States

National Force Calibrations Plus

2250 Lake Mist Drive, 37421, Chattanooga, TN, United States

A2LA|2621.01ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
5
Standards
9
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at National Force Calibrations Plus?

Claim this profile to keep it accurate.

Register record

A2LARefreshed
2621.01Active

Accredited standards

9

Our reading of the A2LA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

ASTM E4Name not checked yet
As written on the certificate · Line 1 (A2LA 2621.01)

ISO/IEC 17025:2017; ASTM E4; ISO7500

As written on the certificate · Line 2 (A2LA 2621.01)

ASTM E4; ISO7500; ASTM E4; ISO 5893; ASTM E2658; ASTM E83; ISO 9513; ASTM E 2309; ASTM E898; NIST Handbook 44

ASTM E83Name not checked yet
As written on the certificate · Line 2 (A2LA 2621.01)

ASTM E4; ISO7500; ASTM E4; ISO 5893; ASTM E2658; ASTM E83; ISO 9513; ASTM E 2309; ASTM E898; NIST Handbook 44

ASTM E145Name not checked yet
As written on the certificate · Line 3 (A2LA 2621.01)

Elements of ASTM E145 section 4

ASTM E898Name not checked yet
As written on the certificate · Line 2 (A2LA 2621.01)

ASTM E4; ISO7500; ASTM E4; ISO 5893; ASTM E2658; ASTM E83; ISO 9513; ASTM E 2309; ASTM E898; NIST Handbook 44

ASTM E2309Name not checked yet
As written on the certificate · Line 2 (A2LA 2621.01)

ASTM E4; ISO7500; ASTM E4; ISO 5893; ASTM E2658; ASTM E83; ISO 9513; ASTM E 2309; ASTM E898; NIST Handbook 44

ASTM E2658Name not checked yet
As written on the certificate · Line 2 (A2LA 2621.01)

ASTM E4; ISO7500; ASTM E4; ISO 5893; ASTM E2658; ASTM E83; ISO 9513; ASTM E 2309; ASTM E898; NIST Handbook 44

ISO 5893Rubber and plastics test equipment - Tensile, flexural and compression types (constant rate of traverse) - Specification
As written on the certificate · Line 2 (A2LA 2621.01)

ASTM E4; ISO7500; ASTM E4; ISO 5893; ASTM E2658; ASTM E83; ISO 9513; ASTM E 2309; ASTM E898; NIST Handbook 44

ISO 7500Name not checked yet
As written on the certificate · Line 1 (A2LA 2621.01)

ISO/IEC 17025:2017; ASTM E4; ISO7500

As written on the certificate · Line 2 (A2LA 2621.01)

ASTM E4; ISO7500; ASTM E4; ISO 5893; ASTM E2658; ASTM E83; ISO 9513; ASTM E 2309; ASTM E898; NIST Handbook 44

ISO 9513Metallic materials - Calibration of extensometer systems used in uniaxial testing
As written on the certificate · Line 2 (A2LA 2621.01)

ASTM E4; ISO7500; ASTM E4; ISO 5893; ASTM E2658; ASTM E83; ISO 9513; ASTM E 2309; ASTM E898; NIST Handbook 44

Scope as published by A2LA

5 lines
A2LA

ISO/IEC 17025

Active

2621.01

The scope document we hold says it is valid until 2027-09-30.

View scope

Accredited scope, certificate 2621.01

LineDisciplineMethodMatrixRange
1dimensional; mechanicalISO/IEC 17025:2017; ASTM E4; ISO7500-0.1 to 50 in; lbf
2mechanicalASTM E4; ISO7500; ASTM E4; ISO 5893; ASTM E2658; ASTM E83; ISO 9513; ASTM E 2309; ASTM E898; NIST Handbook 44-0.0005 to 600000 lbf; in/min; in; g; lb
3mechanicalElements of ASTM E145 section 4-0 to 5000 psi; °C; hr
4-
(A2LA Cert. No. 2621.01) 11/17/2025 Page 4 of 4 4 In the statement of CMC, a percent is defined as the percentage of indicated value unless otherwise noted. 5 The type of instrument or material being calib rated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 6 This scope meets A2LA’s P112 Flexible Scope Policy
5-
For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited NATIONAL FORCE CALIBRATIONS PLUS LLC Chattanooga, TN for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This laboratory also meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 17th day of November 2025. __ _____________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 2621.01 Valid to September 30, 2027

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

2250 Lake Mist Drive, Chattanooga, TN, 37421, US

35.04572, -85.30949

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.