Miejskie Przedsiębiorstwo Energetyki Cieplnej Wodociągów i Kanalizacji Spółka z o.o. w Środzie Wlkp.
Chwałkowo 25, 63-000, Środa Wlkp., Poland
- Accredited standards
- 14
- PCA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the PCA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 14 standard numbers and the 14 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO12
ISO 5667-5Water quality - Sampling - Part 5: Guidance on sampling of drinking water from treatment works and piped distribution systems
ISO 5667-10Water quality - Sampling - Part 10: Guidance on sampling of waste water
ISO 5815-1Water quality - Determination of biochemical oxygen demand after n days (BODn) - Part 1: Dilution and seeding method with allylthiourea addition
ISO 6059Water quality - Determination of the sum of calcium and magnesium - EDTA titrimetric method
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
ISO 7027-1Water quality - Determination of turbidity - Part 1: Quantitative methods
ISO 7887Water quality - Examination and determination of colour
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 9308-2Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 2: Most probable number method
ISO 10523Water quality - Determination of pH
ISO 15705Water quality - Determination of the chemical oxygen demand index (ST-COD) - Small-scale sealed-tube method
ISO 19458Water quality - Sampling for microbiological analysis
Other standards2
EN 872Water quality - Determination of suspended solids - Method by filtration through glass fibre filters
EN 27888Water quality - Determination of electrical conductivity
PN-EN ISO 19458:2007; PN-ISO 5667-5:2017-10; PN-EN ISO 7027-1:2016-09; PN-EN ISO 7887:2012; PN-EN 27888:1999; PB/04; PN-ISO 6059-1999; PN-EN ISO 9308-2:2014-06; PN-EN ISO 6222:2004; PN-EN ISO 7899-2:2004; PB/02
PN-ISO 5667-10:2021-11; PN-ISO 15705:2005; PN-EN ISO 5815-1:2019-12; PN-EN 872:2007+Ap1:2007; PB/06; PB/01; PN-EN ISO 10523:2012
Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-06.
Scope as published by PCA
3 lines
ISO/IEC 17025
ActiveAB 1193
The scope document we hold says it was valid until 2026-06-24. That date has passed, so our copy may be out of date. We downloaded it from the PCA register on 2026-03-13. Check the PCA register for the current scope.
Accredited scope, certificate AB 1193
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | Drinking waterShow page textExtracted from the scope document; tables may not line up. View scope for the original. PCA Zakres akredytacji Nr AB 1193
Scope of accreditation No. AB 1193
ZAKRES AKREDYTACJI
LABORATORIUM BADAWCZEGO
SCOPE OF ACCREDITATION FOR TESTING LABORATORY
Nr/No. AB 1193
wydany przez / issued by
POLSKIE CENTRUM AKREDYTACJI
01-382 Warszawa ul. Szczotkarska 42
Wydanie/Issue 14 z/of 29.05.2024
p.o. KIEROWNIK A DZIAŁU AKREDYTACJI
BADAŃ CHEMICZNYCH
MARCIN BEKAS
Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr AB 1193 z dnia 15.10.2020 r.
Cykl akredytacji od 30.05.2022 r. do 24.06.2026 r.
Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl
This document is an annex to accreditation certificate No. AB 1193 of 15.10.2020
Accreditation cycle from 30.05.2022 to 24.06.2026
The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl
Wydanie nr / Issue No. 14, 29.05.2024 1/4
Nazwa i adres / Name and address
MIEJSKIE PRZEDSIĘBIORSTWO ENERGETYKI CIEPLNEJ
WODOCIĄGÓW I KANALIZACJI Sp. z o.o. w Środzie Wlkp.
ul. Harcerska 16
63-000 Środa Wielkopolska
LABORATORIUM
Chwałkowo 25
63-000 Środa Wielkopolska
Kod identyfikacyjny /
Identification code *) Dziedzina i przedmiot badań / Field of testing and item:
- C/28/P; C/29/P;
C/30P
- K/28/P; K/29/P
- N/28/P; C/29/P;
N/30/P
- Badania chemiczne i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków / Chemical
tests and sampling of water, drinking water, sewage
- Badania mikrobiologiczne i pobieranie próbek wody, wody do spożycia przez ludzi / Microbiological
tests and sampling of water, drinking water
- Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia przez ludzi, ścieków /
Tests of physical properties and sampling of water, drinking water, sewage
Wersja strony/Page version: A
*) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB -07 dostępnym na stronie internetowej www.pca.gov.pl /
The identification code according to the Annex to document DAB -07, available at PCA website www.pca.gov.pl
AB 1193 | - |
| 2 | PN-EN ISO 19458:2007; PN-ISO 5667-5:2017-10; PN-EN ISO 7027-1:2016-09; PN-EN ISO 7887:2012; PN-EN 27888:1999; PB/04; PN-ISO 6059-1999; PN-EN ISO 9308-2:2014-06; PN-EN ISO 6222:2004; PN-EN ISO 7899-2:2004; PB/02 | Drinking water | See scope document |
| 3 | PN-ISO 5667-10:2021-11; PN-ISO 15705:2005; PN-EN ISO 5815-1:2019-12; PN-EN 872:2007+Ap1:2007; PB/06; PB/01; PN-EN ISO 10523:2012 | Waste water | See scope document |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Poland
- Eko-Projekt W. Z. Żywczyk Spółka JawnaOstrowiec Św. · ~319 kmPCAShares 4 accredited methods and materialsEN ISO 19458:2007ISO 5667-10:2021-11Drinking water
- AQUANET Laboratorium Spółka z o.o.Poznań · ~31 kmPCAShares 3 accredited methods and materialsEN ISO 19458:2007Drinking waterWaste water
- Laboratorium Usługowo-Badawcze "Biochemik"Piła · ~107 kmPCAShares 3 accredited methods and materialsISO 5667-10:2021-11Drinking waterWaste water
- LabAnalitykaBrzeg Dolny · ~114 kmPCAShares 3 accredited methods and materialsISO 5667-10:2021-11Drinking waterWaste water
- Centrum Badań Jakości Spółka z ograniczoną odpowiedzialnościąLubin · ~118 kmPCAShares 3 accredited methods and materialsISO 5667-10:2021-11Drinking waterWaste water
Accreditation data refreshed from the PCA register on .