PME Services

1584 north batavia street suite 1, 92867, Orange, CA, United States

Visit website
A2LA 4938.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
4
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 4 scope lines.

A2LA certificate 4938.01 · 4 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4938.01) 08/15/2024 Page 1 of 3 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 PME SERVICES INC 1584 North Batavia Street Suite 1 Orange, CA 92867 Cory Clark Phone: 714 418 1444 CALIBRATION Valid To: July 31, 2026 Certificate Number: 4938.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 4: I. Dimensional Parameter/Equipment Range CMC2, 5 (±) Comments Calipers – Outside Micrometer Digital Caliper Up to 6 in Up to 6 in Up to 8 in Up to 24 in (7.2L + 3.5) µin (14L + 3) µin (14L + 3) µin (2.5L + 450) µin Gage blocks Micrometers Up to 6 in (7.2L + 3.5) µin Gage blocks II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 3 (±) Comments DC Current – Measure (0 to 100) µA (>0.1 to 1) mA (>1 to 10) mA (>10 to 100) mA (>0.1 to 1) A 15 µA/A + 0.8 nA 10 µA/A + 5 nA 23 µA/A + 50 nA 46 µA/A + 0.5 µA 43 µA/A + 10 µA HP 3458A, measurements obtained by averaging 100 readings using sampling mode
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4938.01) 08/15/2024 Page 2 of 3 Parameter/Equipment Range CMC2, 3 (±) Comments DC Voltage – Measure (0 to 100) mV (>0.1 to 1) V (>1 to 10) V (>10 to 100) V (>100 to 1000) V 5.7 µV/V + 0.3 µV 2.9 µV/V + 0.3 µV 3.2 µV/V + 0.5 µV 6.0 µV/V + 30 µV 2.2 µV/V + 0.1 mV HP 3458A, measurements obtained by averaging 100 readings using sampling mode Resistance – Measure (0 to 10) Ω (>10 to 100) Ω (>0.1 to 10) kΩ (>1 to 10) kΩ (>10 to 100) kΩ (>0.1 to 1) MΩ (>1 to 10) MΩ (>10 to 100) MΩ 9.1 µΩ/Ω + 0.5µΩ 9.8 µΩ/Ω + 5 µΩ 3.7 µΩ/Ω + 0.5 mΩ 3.5 µΩ/Ω + 5 mΩ 4.8 µΩ/Ω + 50 mΩ 9.2 µΩ/Ω + 2 Ω 15 µΩ/Ω + 0.1 kΩ 98 µΩ/Ω + 1 kΩ HP 3458A, measurements obtained by averaging 100 readings using sampling mode DC Current – Generate (0 to 330) µA (>0.33 to 3.3) mA (>3.3 to 33) mA (>33 to 330) mA (>0.33 to 1.1) A (>1.1 to 11) A (>11 to 20) A 18 µA/A + 23 nA 14 µA/A + 56 nA 9.4 µA/A + 360 nA 40 µA/A + 2.8 µA 30 µA/A + 43 µA 160 µA/A + 620 µA 250 µA/A + 870 µA Fluke 5520A/SC1100 DC Voltage – Generate (0 to 330) mV (>0.33 to 3.3) V (>3.3 to 33) V (>33 to 330) V (>330 to 1000) V 6.7 µV/V + 1.3 µV 7.6 µV/V + 2.5 µV 6.3 µV/V + 25 µV 5.4 µV/V + 150 µV 3.1 µV/V + 1.5 mV Fluke 5520A/SC1100 Resistance – Generate (0 to 11) Ω (>11 to 33) Ω (>33 to 110) Ω (>110 to 330) Ω (>0.33 to 1.1) kΩ (>1.1 to 3.3) kΩ (>3.3 to 11) kΩ (>11 to 33) kΩ (>33 to 110) kΩ (>110 to 330) kΩ (>330 to 1.1) MΩ (>1.1 to 3.3) MΩ (>3.3 to 11) MΩ (>11 to 33) MΩ (>33 to 110) MΩ 57 µΩ/Ω + 41 µΩ 27 µΩ/Ω + 31 µΩ 11 µΩ/Ω + 29 µΩ 7.2 µΩ/Ω + 29 µΩ 7.1 µΩ/Ω + 29 µΩ 14 µΩ/Ω + 29 µΩ 10 µΩ/Ω + 29 µΩ 9.7 µΩ/Ω + 29 µΩ 9.1 µΩ/Ω + 29 µΩ 11 µΩ/Ω + 32 µΩ 6.5 µΩ/Ω + 32 µΩ 19 µΩ/Ω + 60 µΩ 40 µΩ/Ω + 130 µΩ 89 µΩ/Ω + 250 µΩ 200 µΩ/Ω + 500 µΩ Fluke 5520A/SC1100
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 4938.01) 08/15/2024 Page 3 of 3 III. Mechanical Parameter/Equipment Range CMC2, 5 (±) Comments Balances 0.001g 0.002 g 0.005 g 0.01 g 0.02 g 0.05 g 0.1 g 0.2 g 0.5 g 1 g 2 g 5 g 10 g 20 g 50 g 100 g 200 g 3.8 µg 4.1 µg 3.2 µg 3.3 µg 3.0 µg 3.5 µg 3.5 µg 5.0 µg 7.7 µg 6.2 µg 7.8 µg 10 µg 33 µg 43 µg 85 µg 160 µg 310 µg Troemner ultra class Pneumatic Pressure – Measuring Equipment (0 to 30) psi (0 to 100) psi (0 to 300) psi (0.000 061P + 0.001) psi (0.000 03P + 0.0067) psi (0.000 065P + 0.015) psi Mensor 8000 ______________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMC’s represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 4 This scope meets A2LA’s P112 Flexible Scope Policy. 5 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches, and P is the numerical value of the reading of the device in psi.
4ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.