Scope lines
7
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 7 scope lines.

A2LA certificate 5877.01 · 7 lines

LineMethodMatrixRange
1CH-5; CH-29Particulate Material; Gaseous Emissions from Stationary Sources; Metals: As, Ag, Ba, Be, Cd, Co, Cr, Cu, Hg, Mn, Ni, P, Pb, Sb, Se, Tl, Zn-
2MINSAL, ISP CH-1 rev. 1 March, 1996; MINSAL, ISP CH-1A rev. 1 March, 1996; MINSAL, ISP CH-2 rev. 1 March, 1996; MINSAL, ISP CH-2C rev. 1 March, 1996; MINSAL, ISP CH-3 rev. 1 March, 1996; MINSAL, ISP CH-3A rev 1 March, 1996; MINSAL, ISP CH-3B rev. 1 March, 1996; MINSAL, ISP CH4 rev. 1 March, 1996; MINSAL, ISP CH-6C rev 1 March, 1996; MINSAL, ISP CH-7E rev 1 March, 1998; MINSAL, ISP CH-10 rev 1 February, 1998; Exempt Resolution No. 2439/2021 SMA Single version - 24-DIC-2021Gases; Particulate Matter-
3Resolution 1743/2019Gases; Flow; Particulate Matter-
4-calibration gas mixtures; primary Standard gases
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

( A2LA Cert. No. 5877.01) 08/03/2026 Page 4 of 6 CALIBRATION I. Fluid Quantities Parameter/Equipment Range CMC2 (±) Comments Nitrogen Oxides (NOx) 25 µmol/mol 50 µmol/mol 100 µmol/mol 250 µmol/mol 500 µmol/mol 1000 µmol/mol 2500 µmol/mol 1.9 µmol/mol 2.8 µmol/mol 5.5 µmol/mol 13 µmol/mol 23 µmol/mol 42 µmol/mol 1.4 x 10 2 µmol/mol Direct comparison of the analyzer response measuring EPA Protocol calibration gas mixtures and/or primary Standard gases concentrations (diluted and/or undiluted). The applied procedure is PINS-13 based on the procedure QU-007 for the calibration of carbon dioxide (CO 2) analyzers (NDIR) technique. Digital Edition N°1 Spain Ministry of Industry, Tourism and Trade - Spanish Metrology Center Sulfur Dioxide (SO₂) 50 µmol/mol 100 µmol/mol 200 µmol/mol 500 µmol/mol 1000 µmol/mol 3000µmol/mol 1.6 µmol/mol 2.9 µmol/mol 5.6 µmol/mol 19 µmol/mol 35 µmol/mol 64 µmol/mol Direct comparison of the analyzer response measuring EPA Protocol calibration gas mixtures and/or primary Standard gases concentrations (diluted and/or undiluted). The applied procedure is PINS-13 based on the procedure QU-007 for the calibration of carbon dioxide (CO 2) analyzers (NDIR) technique. Digital Edition N°1 Spain Ministry of Industry, Tourism and Trade - Spanish Metrology Center
-
5-gas mixtures
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 5877.01) 08 /03/2026 Page 5 of 6 Parameter/Equipment Range CMC2 (±) Comments Carbon Monoxide (CO) 60 µmol/mol 100 µmol/mol 200 µmol/mol 500 µmol/mol 1000 µmol/mol 2000 µmol/mol 5000 µmol/mol 2.3 µmol/mol 3.1 µmol/mol 5.8 µmol/mol 14 µmol/mol 24 µmol/mol 41 µmol/mol 1.4 x10 2 µmol/mol Direct comparison of the analyzer response measuring EPA Protocol calibration gas mixtures and/or primary Standard gases concentrations (diluted and/or undiluted). The applied procedure is PINS-13 based on the procedure QU-007 for the calibration of carbon dioxide (CO 2) analyzers (NDIR) technique. Digital Edition N°1 Spain Ministry of Industry, Tourism and Trade - Spanish Metrology Center Carbon Dioxide (CO₂) 10 cmol/mol 20 cmol/mol 0.31 cmol/mol 0.51 cmol/mol Direct comparison of the analyzer response measuring EPA Protocol calibration gas mixtures and/or primary Standard gases concentrations (diluted and/or undiluted). The applied procedure is PINS-13 based on the procedure QU-007 for the calibration of carbon dioxide (CO 2) analyzers (NDIR) technique. Digital Edition N°1 Spain Ministry of Industry, Tourism and Trade - Spanish Metrology Center
-
6PINS-13; QU-007Oxygen (O₂)See scope document
7ISO/IEC 17025:2017--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

ANGEL GUARELLO 1699, PEDRO AGUIRRE CERDA, SANTIAGO, Chile, SANTIAGO, CL

-33.49215, -70.66285

Open in Maps

Other Locations

1 other site in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.