SAL Società Acqua Lodigiana srl - Laboratorio Analisi

Via dell'industria 3/5, 26900, Lodi, Italy

Visit website
ACCREDIA 00323ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
12
ACCREDIA certificate
1
Site in our directory
1
ACCREDIA accredited scope

What this lab is accredited for

Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 12 standard numbers and the 10 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO9
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
ISO 11731Water quality - Enumeration of Legionella

Certificate says EN ISO 11731 2019-03 UBA Empfehlung 18. Probably the same standard; not checked against the EN document.

ISO 12846Water quality - Determination of mercury - Method using atomic absorption spectrometry (AAS) with and without enrichment
ISO 14189Water quality - Enumeration of Clostridium perfringens - Method using membrane filtration
ISO 15705Water quality - Determination of the chemical oxygen demand index (ST-COD) - Small-scale sealed-tube method
ISO 16266Water quality - Detection and enumeration of Pseudomonas aeruginosa - Method by membrane filtration
ISO 23695Water quality - Determination of ammonium nitrogen in water - Small-scale sealed tube method
Other standards3
APAT CNR IRSA 4020 Man 29 2003
EN 27888Water quality - Determination of electrical conductivity
EPA 300.1

Read from the scope as published by ACCREDIA. Register refreshed 2026-11-20.

Scope as published by ACCREDIA

2 lines
ACCREDIA

ISO/IEC 17025

Active

00323

View scope

Accredited scope, certificate 00323

LineMethodMatrixRange
1UNI CEI EN ISO/IEC 17025:2018; Rapporti ISTISAN 2007/31 pag 68 Met ISS BCA023; UNI EN ISO 9308-1:2017; UNI EN 27888:1995; UNI EN ISO 6222:2001; UNI EN ISO 14189:2016; Rapporti ISTISAN 2007/05 pag 59 Met ISS A006A; UNI EN ISO 7899-2:2003; Rapporti ISTISAN 2007/05 pag 22 Met ISS A001A; UNI EN ISO 16266:2008; Rapporti ISTISAN 2007/05 pag 106 Met ISS A011A; UNI 10678:1998; UNI EN ISO 11731:2017; APHA Standard Methods for Examination of Water and Wastewater 6200 B (2020); UNI 11758:2019; APAT CNR IRSA 3030 Man 29 2003Drinking water-
2EPA 300.1 1997 part A + EC 1999; EPA 300.1 1997 part B + EC 1999; UNI EN ISO 12846:2013; Rapporti ISTISAN 2019/07 pag 43 Met ISS CAC015; APAT CNR IRSA 7010 B Man 29 2003 MPN; APAT CNR IRSA 7030 B Man 29 2003 MPN; APAT CNR IRSA 7080 Man 29 2003; APAT CNR IRSA 4020 Man 29 2003; UNI 11757:2019; APHA Standard Methods Examination of Water and Wastewater 5210 D (2019); ISO 15705:2002; APAT CNR IRSA 2090 B Man 29 2003; UNI ISO 23695:2023; UNI 11759:2019Waste water-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Via dell'industria 3/5, Lodi, 26900, IT

45.26131, 9.49168

Open in Maps

Accreditation data refreshed from the ACCREDIA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.