Fletcher, NC, United States

Visit website
A2LA 1504.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
5
A2LA certificate
1
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 5 standard numbers and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.

ASTM D1646
ASTM D2084
ASTM D2240Standard Test Method for Rubber Property - Durometer Hardness
ASTM D5289
ASTM E83

Read from the A2LA scope document we downloaded on 2026-08-05. Register refreshed 2026-11-20.

Scope as published by A2LA

6 lines
A2LA

ISO/IEC 17025

Active

1504.01

The scope document we hold says it is valid until 2027-06-30.

View scope

Accredited scope, certificate 1504.01

LineMethodMatrixRange
1ISO/IEC 17025:2017-to 8 in
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1504.01) Revised 3/9/2026 Page 2 of 5 II. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of Thermocouple Indicators3 – Generate and Measure Type J Type K Type T (-210 to 1200) °C (-200 to 1372) °C (-250 to 400) °C 0.22 °C 0.23 °C 0.23 °C Omega / Martel CL3001 Electrical Calibration of RTD Indicators 3 – Generate and Measure Pt 385, 100 Ω Pt 385, 1 kΩ Pt 3902, 100 Ω Pt 3926, 100 Ω Cu 427, 10 Ω (-200 to 800) °C (-190 to 630) °C (-200 to 630) °C (-200 to 630) °C (-100 to 260) °C 0.18 °C 0.18 °C 0.18 °C 0.18 °C 0.18 °C Omega / Martel CL3001 III. Mechanical Parameter/Equipment Range CMC2, 5 (±) Comments Force – Measure3 Force Gages and Tensile Testers Crosshead Speed (0-200) lbf (200 to 2000) lbf (2000 to 5000) lbf (0 to 20) in/min 0.078 lbf 0.25 lbf 0.14 % of full scale 0.037 in/min ASTM E4 w/ load cells Load cell comparison Calibrated scale and stopwatch Pressure – Measuring Equipment3 (0 to 300) psi (300-3000) psi 0.19 PSI 1.8 PSI Druck pressure gauges
3ASTM E83-See scope document
4ASTM D2240; ASTM D2084; ASTM D5289; ASTM D1646Durometers; Rheometer; Mooney ViscometerSee scope document
5--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1504.01) Revised 3/9/2026 Page 5 of 5 VI. Thermodynamics Parameter/Equipment Range CMC2, 5 (±) Comments Temperature – Measure3 (-200 to 350) °C 0.35 °C RTD/Thermocouple; calibration of various temperature devices such as oil baths and ovens Relative Humidity – Measure3 (10 to 75) % RH 1.3 % RH Vaisala HMI41 and HMP46 VII. Time and Frequency Parameter/Equipment Range CMC2, 5 (±) Comments Time Interval – Measure3 (0 to 100) hr 3 s/day Digital stop watch ____________________________________________ 1 This laboratory offers commercial calibration service and field calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, R is defined as the resolution of the device. 5 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 6 This scope meets A2LA’s P112 Flexible Scope Policy.
-200 to 350 °C
6ISO/IEC 17025:2017--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.