Stuart Hunt & Associates
5949 Ambler Drive, Mississauga, Ontario, ON L4W 2K2, Canada, Mississauga, Ontario, Canada
Visit website- Scope lines
- 3
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 3 scope lines.
A2LA certificate 3215.01 · 3 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3215.01) 02/12/2026 Page 1 of 2
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
STUART HUNT & ASSOCIATES, LTD.
5949 Ambler Drive
Mississauga, Ontario, L4W 2K2
CANADA
Cameron Musgrave Phone: 905 602 8871
CALIBRATION
Valid To: January 31, 2028 Certificate Number: 3215.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations
1, 3:
I. Ionizing Radiation
Parameter/Equipment
Range
CMC2 (±)
Comments
Radiation Protection
Survey Instruments –
137Cs Exposure (Gamma)
241AmBe Exposure
(Neutron)
1 μSv/hr to 1.4 Sv/hr
(20.6 to 1170) μSv/hr
5.5 % of reading
11 % of reading
Hopewell G10-2-150
Transfer standard
Contamination
Instruments
(1 to 9.9 x 106) cpm
6.4 % of reading
Ludlum model 500
pulser
Pulsers
(1 to 9.999 x 106) cpm,
(400 to 2100) V,
(-4 to 4) V pulse amplitude,
(1.5 to 1.9) µs negative pulse,
< 2.25 µs positive pulse
6.1 % of reading
Precision counter,
multimeter with
attenuator,
oscilloscope | ||
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3215.01) 02/12/2026 Page 2 of 2
Parameter/Equipment
Range
CMC2 (±)
Comments
Portable Nuclear
Moisture/Density Gauges –
Density
Moisture
(1763 to 2705) kg/m
3
Up to 381.2 kg/m3
0.5 % of reading
2.2 % of reading
Density and
moisture blocks
_______________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 This scope meets A2LA’s P112 Flexible Scope Policy. | 1763 to 2705 kg/m3 |
| 3 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
5949 Ambler Drive, Mississauga, Ontario, ON L4W 2K2, Canada, Mississauga, Ontario, CA
43.58962, -79.64439
Open in MapsAccreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.