Accredited standards
41
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 41 standard numbers and the 29 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 61000 series13
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments+1 national

National versions in the same scope

KS C 9610-6-1national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments+1 national

National versions in the same scope

KS C 9610-6-2national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments+1 national

National versions in the same scope

KS C 9610-6-3national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.

IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments+1 national

National versions in the same scope

KS C 9610-6-4national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC9
IEC 60092-504
IEC 60204-1Safety of machinery - Electrical equipment of machines - Part 1: General requirements
IEC 61010-1Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
IEC 61010-2-030
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61326-2-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications
IEC 61439-1
IEC 61439-2
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements
IEC 60068 series8
IEC 60068-2-1Environmental testing - Part 2-1: Tests - Test A: Cold
IEC 60068-2-2Environmental testing - Part 2-2: Tests - Test B: Dry heat
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-14Environmental testing - Part 2-14: Tests - Test N: Change of temperature
IEC 60068-2-27Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
IEC 60068-2-30Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
IEC 60068-2-64Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance

Certificate says EN 60068-2-64. Probably the same standard; not checked against the EN document.

IEC 60068-2-78Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
ETSI4
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-17
ETSI EN 301 489-19
IEC 60079 series4
IEC 60079-0
IEC 60079-7Some clauses

Limits written next to it

EN 60079-7 (clause 4.2.5, 6.1 and 6.5 only)

Some clauses. Written next to it on line 3 of A2LA certificate 3154.01.

IEC 60079-7 (clause 4.2.5, 6.1 and 6.5 only)

Some clauses. Written next to it on line 3 of A2LA certificate 3154.01.

IEC 60079-11
IEC 60079-15Some clauses

Limits written next to it

EN 60079-15 (clause 6.2 and 6.5 only)

Some clauses. Written next to it on line 3 of A2LA certificate 3154.01.

IEC 60079-15 (clause 6.2 only)

Some clauses. Written next to it on line 3 of A2LA certificate 3154.01.

CISPR3
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+1 national

National versions in the same scope

KS C 9811national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55011. Probably the same standard; not checked against the EN document.

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirementsExclusion+1 national

Limits written next to it

EN 55032 (except broadcast receivers)

Exclusion. Written next to it on line 1 of A2LA certificate 3154.01; Line 4 of A2LA certificate 3154.01.

National versions in the same scope

KS C 9832national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements+1 national

National versions in the same scope

KS C 9835national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

Certificate says EN 55035. Probably the same standard; not checked against the EN document.

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.

Scope as published by A2LA

7 lines
A2LA

ISO/IEC 17025

Active

3154.01

The scope document we hold says it is valid until 2027-07-31.

View scope

Accredited scope, certificate 3154.01

LineMethodMatrixRange
1CISPR 11; CISPR 32; EN 55011; EN 55032; ICES-001; ICES-003; KS C 9811; KS C 9832; IEC 61000-3-2; EN 61000-3-2; IEC 61000-3-3; EN 61000-3-3; IEC 61000-4-2; EN 61000-4-2; IEC 61000-4-3; EN 61000-4-3; IEC 61000-4-4; EN 61000-4-4; IEC 61000-4-5; EN 61000-4-5-to 1 GHz
2IEC 61000-4-6; EN 61000-4-6; IEC 61000-4-8; EN 61000-4-8; IEC 61000-4-11; EN 61000-4-11; IEC 61000-6-1; EN 61000-6-1; KS C 9610-6-1; IEC 61000-6-2; EN 61000-6-2; KS C 9610-6-2; IEC 61000-6-3; EN 61000-6-3; KS C 9610-6-3; IEC 61000-6-4; EN 61000-6-4; KS C 9610-6-4; CISPR 35; EN 55035; KS C 9835; IEC 61326-1; EN 61326-1; IEC 61326-2-1; EN 61326-2-1; EN 301 489-1; EN 301 489-3; EN 301 489-17; EN 301 489-19; KS X 3124; KS X 3126; IEC 61010-1; UL 61010-1; EN 61010-1; CAN/CSA-C22.2 No. 61010-1; IEC 61010-2-030; UL 61010-2-030; EN 61010-2-030; CAN/CSA-C22.2 No. 61010-2-030; IEC 62368-1; UL 62368-1; EN 62368-1; CAN/CSA-C22.2 No. 62368-1; IEC 60204-1; EN 60204-1; NFPA 79; IEC 61439-1; EN 61439-1; IEC 61439-2; EN 61439-2; IEC 60079-0; UL 60079-0; EN 60079-0--
3CAN/CSA C22.2 No. 60079-0; IEC 60079-15; UL 60079-15; EN 60079-15; CAN/CSA C22.2 No. 60079-15; IEC 60079-7; UL 60079-7; EN 60079-7; CAN/CSA 60079-7; IEC 60079-11; UL 60079-11; EN 60079-11; CAN/CSA 60079-11; UL 121201; CSA C22.2 No. 213; IEC 60068-2-1; IEC 60068-2-2; IEC 60068-2-30; IEC 60068-2-14; IEC 60068-2-78; IEC 60092-504; IEC 60068-2-6; IEC 60068-2-27; IEC 60068-2-64--
4CISPR 11; EN 55011; EN 55032; ICES-001; ICES-003; IEC 61000-4-2; EN 61000-4-2; IEC 61000-4-3; EN 61000-4-3; IEC 61000-4-4; EN 61000-4-4; IEC 61000-4-5; EN 61000-4-5; IEC 61000-4-6; EN 61000-4-6; IEC 61000-4-8; EN 61000-4-8; IEC 61000-4-11; EN 61000-4-11; IEC 61000-6-1; EN 61000-6-1; KS C 9610-6-1; IEC 61000-6-2; EN 61000-6-2; KS C 9610-6-2; IEC 61000-6-3; EN 61000-6-3; KS C 9610-6-3; IEC 61000-6-4; EN 61000-6-4; KS C 9610-6-4; CISPR 35; EN 55035; KS C 9835; IEC 61326-1; EN 61326-1; IEC 61326-2-1; EN 61326-2-1; IEC 61010-1; UL 61010-1; EN 61010-1; CAN/CSA-C22.2 No. 61010-1; IEC 61010-2-030; UL 61010-2-030; EN 61010-2-030; CAN/CSA-C22.2 No. 61010-2-030; IEC 62368-1; UL 62368-1; EN 62368-1; CAN/CSA-C22.2 No. 62368-1-to 2.7 GHz
5IEC 60068-2-1; IEC 60068-2-2; IEC 60068-2-30; IEC 60068-2-78--
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3154.01) 08/05/2025 Page 6 of 6 G.10 Resistor Test G.11 Capacitors and RC Test G.12 Optocouplers Test G.13 PWB Test G.14 Coatings on Component Terminals Test G.15 Pressurized Liquid Filled Components Test G.16 IC with Capacitor Discharge Test Annex H Telephone Ringing Signal Test Annex J Insulated Winding Wires Test Annex K Safety Interlocks Test Annex R Limited Short Circuit Test Annex S Resistance to Heat and Fire Test Annex U Mechanical Strength of CRT Test Annex Y Outdoor Enclosure Test Annex DVJ Acoustic of Telecommunication Equipment Test
7

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited NATIONAL INSTRUMENTS CORPORATION Austin, TX for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 5th day of August 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 3154.01 Valid to July 31, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

11500 North Mopac Expressway, Austin, TX, 78759-3504, US

30.27113, -97.74370

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.