FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
China

Hangzhou TDT Technologies Co.,

Room 101, Building 3, No.12, Binwen Road, Xixing Street, Binjiang District, Hangzhou, Zhejiang, 310051, People's Republic of China, Hangzhou, Zhejiang, China

A2LA|4037.01ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
6
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Hangzhou TDT Technologies Co.,?

Claim this profile to keep it accurate.

Register record

A2LARefreshed
4037.01Active

Certificates and scope

1
A2LA

ISO/IEC 17025

Active

4037.01

The scope document we hold says it is valid until 2027-03-31.

View scope

Accredited scope, certificate 4037.01

LineDisciplineMethodMatrixRange
1electricalCISPR 25; CISPR 25:2016; EN IEC 55025; GB/T 18655; GB 14023; EN ISO 14982; EN 55012; EN 55012:2007+A1: 2009; CISPR 12:2007+A1:2009; ISO 7637-2; GB/T 33014.2; ISO 10605; ISO 10605:2008+A1:2014; GB/T 19951; ISO 11452-2; GB/T 33014.2; ISO 11452-4; GB/T 33014.4; GB/T 33014.9; ISO 11452-9; GB/T 21437.2; GB/T 21437.2-2008; ISO 7637-3; GB/T 21437.3; ISO 16750-2; GB/T 33014.8; ISO 11452-8--
2electricalISO 14982; EN ISO 14982; ECE R10; ECE R10 Rev.6+A1+A2; EN 15194; EN 17128; GB 34660; CFR 47, FCC Part 15 B; CFR 47, FCC Part 18; CISPR 11; GB 4824; EN 55011; EN 55011:2016+A1:2017+A11:2020+A2:2021; ICES-001; ICES-002; ICES-003; ICES-003 Issue 7; ICES-005; CISPR 22:2008; EN 55022:2010; GB/T 9254.1-2021; CISPR 14-1; EN 55014-1; EN 55014-1:2017; GB 4343.1; CISPR 32; CISPR 32:2015+A1:2019; EN 55032; EN 55032:2015; EN 55032:2015/A11:2020; EN 55032:2015/A1:2020; BS EN 55032; BS EN 55032:2015+A1:2020; VCCI-CISPR 32; VCCI-CISPR 32:2016; AS/NZS CISPR 32; AS/NZS CISPR 32:2015; AS/NZS CISPR 32:2015/AMD 1:2020; CISPR 15; EN 55015; EN IEC 55015:2019/A11:2020; EN IEC 55015:2019; GB 17743; CISPR 16-2-1; GB/T 6113.201; CISPR 16-2-3; GB/T 6113.203; IEC 61000-3-2; EN 61000-3-2; EN 61000-3-2:2014; EN IEC 61000-3-2:2019+A1:2021; GB 17625.1; EN IEC 61000-3-2:2019+A2:2024; IEC 61000-3-3; EN 61000-3-3; EN 61000-3-3:2013; EN 61000-3-3:2013+A2:2021+AC:2022-01; EN 61000-3-3:2013+A1:2019; EN 61000-3-3:2013+A2:2021; GB 17625.2; IEC 61000-4-2; GB/T 17626.2; EN 61000-4-2; IEC 61000-4-3; GB/T 17626.3; EN 61000-4-3--
3----
4electricalEN 55035:2017; EN 55035:2017/A11:2020; BS EN 55035:2017+A11:2020; CISPR 35; CISPR 35:2016; EN 55024; EN 55024:2010; EN 55024:2010/A1:2015; ETSI EN 300 328; ETSI EN 301 893; ETSI EN 302 502; ETSI EN 300 220; ETSI EN 300 330; ETSI EN 300 440; ETSI EN 303 413; EN 62311; EN 62479; RSS-GEN; RSS-210; RSS-247; AS/NZS4268; LP0002; MIC Notice NO.88 Annex01; MIC Notice NO.88 Annex43; MIC Notice NO.88 Annex44; MIC Notice NO.88 Annex45; CFR 47, FCC Part 15, Subparts C, E; ANSI C63.4:2014; FCC MP-5:1986-to 40000 MHz
5electricalANSI C63.10:2013; ANSI C63.10:2020+cor1:2023; FCC KDB 905462 D02 (v02)-to 40000 MHz
6electrical---

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.