Miejskie Przedsiębiorstwo Wodociągów i Kanalizacji
ul. Starodworska 100, 50-458, Mokry Dwór, Poland
- Accredited standards
- 31
- PCA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the PCA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 31 standard numbers and the 31 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO22
ISO 5815-1Water quality - Determination of biochemical oxygen demand after n days (BODn) - Part 1: Dilution and seeding method with allylthiourea addition
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
ISO 7027-1Water quality - Determination of turbidity - Part 1: Quantitative methods
ISO 7150-1Water quality - Determination of ammonium - Part 1: Manual spectrometric method
ISO 7393-2Water quality - Determination of free chlorine and total chlorine - Part 2: Colorimetric method using N,N-dialkyl-1,4-phenylenediamine, for routine control purposes
ISO 7887Water quality - Examination and determination of colour
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
ISO 9308-2Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 2: Most probable number method
ISO 9377-2Water quality - Determination of hydrocarbon oil index - Part 2: Method using solvent extraction and gas chromatography
ISO 10301Water quality - Determination of highly volatile halogenated hydrocarbons - Gas-chromatographic methods
ISO 10304-1Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 1: Determination of bromide, chloride, fluoride, nitrate, nitrite, phosphate and sulfate
Show all 22
ISO 10304-4Water quality - Determination of dissolved anions by liquid chromatography of ions - Part 4: Determination of chlorate, chloride and chlorite in water with low contamination
ISO 10523Water quality - Determination of pH
ISO 11731Water quality - Enumeration of Legionella
ISO 11885Water quality - Determination of selected elements by inductively coupled plasma optical emission spectrometry (ICP-OES)
ISO 14189Water quality - Enumeration of Clostridium perfringens - Method using membrane filtration
ISO 14911Water quality - Determination of dissolved Li+, Na+, NH4+, K+, Mn2+, Ca2+, Mg2+, Sr2+ and Ba2+ using ion chromatography - Method for water and waste water
ISO 15705Water quality - Determination of the chemical oxygen demand index (ST-COD) - Small-scale sealed-tube method
ISO 17289Water quality - Determination of dissolved oxygen - Optical sensor method
ISO 17294-2Water quality - Application of inductively coupled plasma mass spectrometry (ICP-MS) - Part 2: Determination of selected elements including uranium isotopes
ISO 19458Water quality - Sampling for microbiological analysis
EN6
EN 872Water quality - Determination of suspended solids - Method by filtration through glass fibre filters
EN 1484Water analysis - Guidelines for the determination of total organic carbon (TOC) and dissolved organic carbon (DOC)
EN 1622Water quality - Determination of the threshold odour number (TON) and threshold flavour number (TFN)
EN 1899-2Water quality - Determination of biochemical oxygen demand after n days (BODn) - Part 2: Method for undiluted samples
EN 26777Water quality - Determination of nitrite - Molecular absorption spectrometric method
EN 27888Water quality - Determination of electrical conductivity
ISO 5667 series3
ISO 5667-5Water quality - Sampling - Part 5: Guidance on sampling of drinking water from treatment works and piped distribution systems
ISO 5667-6Water quality - Sampling - Part 6: Guidance on sampling of rivers and streams
ISO 5667-10Water quality - Sampling - Part 10: Guidance on sampling of waste water
PN-ISO 5667-10:2021-11; PN-77/C-04584; PN-EN ISO 10523:2012; PN-EN 872:2007+Ap1:2007; PN-ISO 15705:2005; PN-EN ISO 10304-1:2009+AC:2012; PN-EN 1899-2:2002; PN-EN ISO 5815-1:2019-12; PN-EN ISO 11885:2009
PN-EN ISO 19458:2007; PN-EN ISO 9308-1:2014-12+ A1:2017-04; PN-EN ISO 9308-2:2014-06; PN-EN ISO 7899-2:2004; PN-EN ISO 6222:2004; PN-EN ISO 14189:2016-10; PN-EN ISO 11731:2017-08 +Ap1:2019-12
PN-ISO 5667-5:2017-10; PN-77/C-04584; PN-EN ISO 7393-2:2018-04; PN-EN 1622:2006; PN-ISO 5667-6:2016-12; ISO 17289:2014; PN-ISO 15705:2005; PN-EN 1899-2:2002; PN-EN ISO 10523:2012; PN-EN 27888:1999; PN-EN ISO 7027-1:2016-09; PN-EN ISO 7887:2012 metoda C +Ap1:2015-06; PN-EN 26777:1999
PN-ISO 7150-1:2002; PN-EN 1484:1999; PN-EN ISO 10304-1:2009+AC:2012; PN-EN ISO10304-4:2022-08; PN-EN ISO 17294-2:2024-04; PB01 wyd. 1.1 z dnia 17.12.2019 r.
PN-EN ISO 10301:2002; PN-EN 872:2007+Ap1:2007; PN-EN ISO 9377-2:2003
PN-EN ISO 14911:2002; PN-EN ISO 11885:2009
Read from the PCA scope document we downloaded on 2026-03-13. Register refreshed 2026-11-06.
Scope as published by PCA
7 lines
ISO/IEC 17025
ActiveAB 1800
The scope document we hold says it is valid until 2029-09-27.
Accredited scope, certificate AB 1800
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | WaterShow page textExtracted from the scope document; tables may not line up. View scope for the original. PCA Zakres akredytacji Nr AB 1800
Scope of accreditation No. AB 1800
ZAKRES AKREDYTACJI
LABORATORIUM BADAWCZEGO
SCOPE OF ACCREDITATION FOR TESTING LABORATORY
Nr/No. AB 1800
wydany przez / issued by
POLSKIE CENTRUM AKREDYTACJI
01-382 Warszawa, ul. Szczotkarska 42
Wydanie/Issue 6 z/of 28.08.2025
p.o. KIEROWNIKA DZIAŁU AKREDYTACJI
BADAŃ CHEMICZNYCH
MARCIN BEKAS
Niniejszy dokument jest załącznikiem do Certyfikatu Akredytacji Nr AB 1800 z dnia 25.07.2024 r.
Cykl akredytacji od 28.08.2025 r. ważny do 27.09.2029 r.
Status akredytacji oraz aktualność zakresu akredytacji można potwierdzić na stronie internetowej PCA www.pca.gov.pl
This document is an annex to accreditation certificate No. AB 1800 of 25.07.2024
Accreditation cycle from 28.08.2025 to 27.09.2029
The status of accreditation and validity of the scope of accreditation can be confirmed at PCA website www.pca.gov.pl
Wydanie nr / Issue No. 6, 28.08.2025 1/8
Nazwa i adres / Name and address
MIEJSKIE PRZEDSIĘBIORSTWO WODOCIĄGÓW I KANALIZACJI S.A.
ul. Na Grobli 19, 50-421 Wrocław
CENTRUM NOWYCH TECHNOLOGII
LABORATORIUM BADANIA WODY I ŚCIEKÓW
ul. Starodworska 100, 50-458 Mokry Dwór
Kod identyfikacyjny /
Identification code *) Dziedzina i przedmiot badań / Field of testing and item:
- C/28/P, C/29/P,
C/30/P
- Badania chemiczne i pobieranie próbek wody, wody do spożycia , ścieków / Chemical tests and
sampling of water, drinking water, sewage
- K/29/P - Badania mikrobiologiczne i pobieranie próbek wody do spożycia przez ludzi / Microbiological tests and
sampling of drinking water
- K/28 - Badania mikrobiologiczne wody / Microbiological tests of water
- N/28/P, N/29/P,
N/30/P
- Badania właściwości fizycznych i pobieranie próbek wody, wody do spożycia, ścieków / Tests of
physical properties and sampling of water, drinking water, sewage
- Q/28/P, Q/29/P - Badania sensoryczne i pobieranie próbek wody, wody do spożycia przez ludzi / Sensory tests and
sampling of water, drinking water
Wersja strony/Page version: A
*) Kod identyfikacyjny zgodnie z załącznikiem do dokumentu DAB -07 dostępnym na stronie internetowej www.pca.gov.pl /
The identification code according to the Annex to document DAB -07, available at PCA website www.pca.gov.pl
AB 1800 | - |
| 2 | PN-ISO 5667-5:2017-10; PN-77/C-04584; PN-EN ISO 7393-2:2018-04; PN-EN 1622:2006; PN-ISO 5667-6:2016-12; ISO 17289:2014; PN-ISO 15705:2005; PN-EN 1899-2:2002; PN-EN ISO 10523:2012; PN-EN 27888:1999; PN-EN ISO 7027-1:2016-09; PN-EN ISO 7887:2012 metoda C +Ap1:2015-06; PN-EN 26777:1999 | Drinking water | 0 to 80 °C |
| 3 | PN-ISO 7150-1:2002; PN-EN 1484:1999; PN-EN ISO 10304-1:2009+AC:2012; PN-EN ISO10304-4:2022-08; PN-EN ISO 17294-2:2024-04; PB01 wyd. 1.1 z dnia 17.12.2019 r. | Drinking water | See scope document |
| 4 | PN-EN ISO 10301:2002; PN-EN 872:2007+Ap1:2007; PN-EN ISO 9377-2:2003 | Drinking water | See scope document |
| 5 | PN-EN ISO 19458:2007; PN-EN ISO 9308-1:2014-12+ A1:2017-04; PN-EN ISO 9308-2:2014-06; PN-EN ISO 7899-2:2004; PN-EN ISO 6222:2004; PN-EN ISO 14189:2016-10; PN-EN ISO 11731:2017-08 +Ap1:2019-12 | Drinking water | - |
| 6 | PN-ISO 5667-10:2021-11; PN-77/C-04584; PN-EN ISO 10523:2012; PN-EN 872:2007+Ap1:2007; PN-ISO 15705:2005; PN-EN ISO 10304-1:2009+AC:2012; PN-EN 1899-2:2002; PN-EN ISO 5815-1:2019-12; PN-EN ISO 11885:2009 | Waste water | 0 to 50 °C |
| 7 | PN-EN ISO 14911:2002; PN-EN ISO 11885:2009 | Waste water | See scope document |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Poland
- Zakład Badania Wód i Ścieków Jacek KubiakŚwierzno · ~124 kmPCAShares 5 accredited methods and materialsISO 5667-10:2021-11ISO 7150-1:2002Drinking water
- ORLEN Laboratorium S.A.Płock · ~206 kmPCAShares 5 accredited methods and materialsEN ISO 10301:2002ISO 5667-10:2021-11ISO 7150-1:2002
- "EKO-SERWIS" s.c. Dorota Markowska, Maciej MarkowskiŁódź · ~285 kmPCAShares 5 accredited methods and materialsEN ISO 10301:2002ISO 5667-5:2017-10Drinking water
- LabAnalitykaBrzeg Dolny · ~362 kmPCAShares 5 accredited methods and materialsEN ISO 10301:2002ISO 5667-10:2021-11Drinking water
- Eko-Projekt W. Z. Żywczyk Spółka JawnaOstrowiec Św. · ~415 kmPCAShares 5 accredited methods and materialsEN ISO 19458:2007ISO 5667-10:2021-11Drinking water
Accreditation data refreshed from the PCA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the PCA entry linked above.