China
Shenzhen Microtest Co.,
101, No. 7, Zone 2, Xinxing Industrial Park, Fuhai Avenue, Xinhe Community, Fuhai Street, Bao 'an District, Shenzhen, Guangdong , 518102, People's Republic of China, Shenzhen, Guangdong, China
A2LA|4674.01ISO/IEC 17025Register collected 2026-08-22
Certificates
1
Scope items
7
Locations
1
Contact this laboratory
Register record
- A2LACollected
- 4674.01Active
Certificates and scope
1A2LA
ISO/IEC 17025
Active4674.01
Accredited scope, certificate 4674.01
| Discipline | Method | Matrix | Range |
|---|---|---|---|
| electrical | - | - | - |
| electrical | 47 CFR, FCC Part 15B (using ANSI C63.4:2014); 47 CFR, FCC Part 18 (using MP-5:1986); 47 CFR, FCC Part 15C (using ANSI C63.10:2013); ANSI C63.4:2014; ANSI C63.10:2013; MP-5:1986; ANSI C63.4; ANSI C63.10; ICES-001; ICES-003; ICES-005; ICES-006; CISPR 11; AS CISPR 11; J55011; EN 55011; BS EN 55011; HKTA 1007; CISPR 14-1; AS/NZS CISPR 14.1; J55014-1; EN IEC 55014-1; BS EN IEC 55014-1; CISPR 15; AS CISPR 15; J55015; EN IEC 55015; BS EN IEC 55015; CISPR 32; AS/NZS CISPR 32; J55032; EN 55032; BS EN 55032; IEC 60601-1-2; EN 60601-1-2; BS EN 60601-1-2; IEC 62040-2; EN IEC 62040-2; BS IEC 62040-2; VCCI V-3 (up to 6 GHz); EN IEC 61000-3-2; IEC 61000-3-2; BS EN IEC 61000-3-2; EN 61000-3-3; IEC 61000-3-3; BS EN 61000-3-2; EN 61000-4-2; IEC 61000-4-2; BS EN 61000-4-2; EN IEC 61000-4-3; BS EN IEC 61000-4-3; IEC 61000-4-3; EN 61000-4-4; IEC 61000-4-4; BS EN 61000-4-4; EN 61000-4-5; IEC 61000-4-5; BS EN 61000-4-5 | - | to 6 GHz |
| electrical | ANSI C63.4:2014; FCC MP-5:1986; ANSI C63.10:2013; FCC KDB 905462; ANSI/TIA-603-E; TIA 102.CAAA-E; ANSI C63.26:2015 | - | to 40000 MHz |
| electrical | RSS-GEN; RSS-102; RSS-102.NS.MEAS; RSS-102.NS.SIM; RSS-112; RSS-130; RSS-131; RSS-132; RSS-133; RSS-134; RSS-139; RSS-192; RSS-195; RSS-197; RSS-198; RSS-199; RSS-210 (≤ 40 GHz); RSS-213; RSS-216 (≤ 40 GHz); RSS-220 (≤ 40 GHz); RSS-247; RSS-310; ETSI EN 300 220-1; ETSI EN 300 220-2; ETSI EN 300 220-3-1; ETSI EN 300 220-3-2; ETSI EN 300 220-4; ETSI EN 300 330; ETSI EN 300 330-1; ETSI EN 300 330-2; ETSI EN 300 440; ETSI EN 300 113; ETSI EN 302 208-1; ETSI EN 302 208-2; ETSI EN 302 208; ETSI EN 303 413; ETSI EN 303 417; ETSI EN 301 357; EN 300 422-1; ETSI EN 300 328; ETSI EN 301 893; ETSI EN 303 345-1; ETSI EN 301 511; ETSI EN 301 908-1; ETSI EN 301 908-2; ETSI EN 301 908-13; HKCA 1020; HKCA 1039; HKCA 1042; HKCA 1048; HKCA 1046; HKCA 1034; HKCA 1043; AS/ACIF S042.3; AS/CA S042.4; ARIB T-33; ARIB T-66; ARIB T-71; Article 2, Paragraph 1 of the Ordinance: Item 19; Item 19-2; Item 19-2-2; Item 19-2-3; Item 19-3; Item 11-3; Item 11-7; Item 11-19; Item 47; Item 78; MIC Notice No. 88, Appendix No. 43; MIC Notice No. 88, Appendix No. 44; AS/NZS 4268; EN 50332-1; BS EN 50332-1; EN 50332-2; BS EN 50332-2; Qi Specification Qi SpecificationPower Transmitter Compliance Tests V1.3.3; Qi Specification Power Transmitter Compliance Tests Version 2.1; Qi Specification MPP Power Transmitter Compliance Tests Version 2.1; Qi Specification Power Receiver Compliance Tests Version 2.1; Qi Specification MPP Power Receiver Compliance Tests Version 2.1; Qi Specification MC-PRx Compliance Tests Version 2.1; Qi Specification Power Transmitter Compliance Tests Version 2.2; Qi Specification MPP Power Transmitter Compliance Tests Version 2.2; Qi Specification Power Receiver Compliance Tests Version 2.2; Qi Specification MPP Power Receiver Compliance Tests Version 2.2; Qi Specification MC-PRx Compliance Tests Version 2.2 | - | to 40 GHz |
| electrical | EN 18031-1; BS EN 18031-1; EN 18031-2; BS EN 18031-2; EN 18031-3; BS EN 18031-3; ETSI TS 103 701; Qi Specification Qi Specification Power Transmitter Compliance Tests V1.3.3; Qi Specification Power Transmitter Compliance Tests Version 2.1; Qi Specification MPP Power Transmitter Compliance Tests Version 2.1; Qi Specification Power Transmitter Compliance Tests Version 2.2; Qi Specification MPP Power Transmitter Compliance Tests Version 2.2 | - | - |
| electrical | IEC 62133-1; EN 62133-1; BS EN 62133-1; JIS C 62133-1; IEC 62133-2; EN 62133-2; BS EN 62133-2; J62133-2; JIS C 62133-2; UL 62133-2; UL 1642; UL 2056; UL 2054; UL 2743; UL 4200A; ANSI/UL 2743; ANSI/CAN/UL 2743; IEC 61951-1; EN 61951-1; BS EN 61951-1; IEC 61951-2; EN 61951-2; BS EN 61951-2; IEC 61960-3; EN 61960-3; BS EN 61960-3; JIS C 8712; IEC 62281; EN IEC 62281; BS EN IEC 62281; IEC 60086-4; EN IEC 60086-4; BS EN IEC 60086-4; IEC 62619; EN IEC 62619; BS EN IEC 62619; UN/ST/SG/AC.10/1/Rev.21 Chapter 3.3 238; UN/ST/SG/AC.10/1/Rev.23 Chapter 3.3 238; UN/ST/SG/AC.10/1/Rev.22(V01.I); UN/ST/SG/AC.10/1/Rev.23(V01.II); ST/SG/AC.10/1/Rev.22(V01.II); ST/SG/AC.10/1/Rev.23(V01.II); ST/SG/AC.10/11/Rev.7/Amend.1 38.3; ST/SG/AC.10/11/Rev.8 38.3; IEC 62680-1-2; EN IEC 62680-1-2; BS EN IEC 62680-1-2; SASO-IEC-62680-1-2; IEC 62680-1-3; EN IEC 62680-1-3; BS EN IEC 62680-1-3; SASO-IEC-62680-1-3; 10 CFR Part 430.32 (w); Title 20. Division 2. Chapter 4. Article 4:1605.1 (u); Title 20. Division 2. Chapter 4. Article 4:1604 (u); 10 CFR Part 430.32(z); Title 20. Division 2. Chapter 4. Article 4:1605.1 (w); Title 20. Division 2. Chapter 4. Article 4:1604 (w); (EU) 2023/826; (EU) No 2019/1782; EN 50563; EN 50564 | - | - |
| - | - | - | - |
Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one.
Labs with overlapping accredited scope in China
- DEKRA Testing and Certification (Suzhou) Co.,Suzhou, Jiangsu ProvinceA2LAShares 2 accredited test methodsANSI C63.4:2014RSS-GEN
- Hunan Ecloud Testing Technology Co.,ChangshaA2LAShares 2 accredited test methodsANSI C63.4:2014RSS-GEN
- Intertek Testing Services (Shanghai FTZ) Co.,ShanghaiA2LAShares 2 accredited test methodsANSI C63.4:2014RSS-GEN
- Shenzhen HUAK Testing Technology Co.,ShenzhenA2LAShares 2 accredited test methodsANSI C63.4:2014RSS-GEN
- Shenzhen Morlab Communications TechnologyShenzhenA2LAShares 2 accredited test methodsANSI C63.4:2014RSS-GEN
Accreditation data collected from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.