CROSS TECHNOLOGIES, INC - LEXINGTON
354 Riverchase Way, 29072, Lexington, SC, United States
Visit website- Scope lines
- 19
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 19 scope lines.
A2LA certificate 1741.12 · 19 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 1 of 18
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
CROSS TECHNOLOGIES, INC
354 Riverchase Way
Lexington, SC 29072
Connie Foster Phone: 800 327 7727
CALIBRATION
Valid To: September 30, 2026 Certificate Number: 1741.12
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with A2LA’s Calibration Program Requirements), accreditation is granted
to this laboratory to perform the following calibrations
1, 8:
I. Chemical
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
pH Meters3 – Fixed
Points
4 pH
7 pH
10 pH
0.03 pH
0.03 pH
0.04 pH
Standard pH solutions
Conductivity Meters3
10 µS/cm
100 µS/cm
1000 µS/cm
1413 µS/cm
10 000 µS/cm
0.56 µS/cm
2.2 µS/cm
5.2 µS/cm
4.7 µS/cm
46 µS/cm
Standard conductivity
solutions
Refractometers3
(5, 10, 25, 40, 60) % Brix
0.033 % + 0.6R Brix
Sucrose solutions
II. Dimensional
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Pin Gage3 – Class Z &
Class ZZ
Up to 1 in
110 µin
Micrometer | to 1 in |
| 2 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 2 of 18
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Calipers3
Up to 40 in
(4.5 + 9.9L) µin + 0.6R
Gage blocks
Micrometers3 (Outside &
Depth)
Up to 40 in
(4.5 + 9.9L) µin + 0.6R
Gage blocks
Inside Micrometers3
Up to 40 in
(4.5 + 9.9L) µin + 0.6R
Gage blocks
Thickness Gages3
Up to 4 in
(6.4 + 3.1L) µin + 0.6R
Gage blocks
Coating Thickness Gages3
Up to 63 mils
0.1 mils
Coating thickness
standards
Cylindrical Measure –
Plain Rings
Pins, Plain Plugs, Discs,
Spheres – External
Diameter
Up to 10 in
Up to 10 in
(17 + 4.6L) µin
(13 + 2.9L) µin
P & W Labmaster
TM w/
XX master rings
P & W LabmasterTM w/
gage blocks
Thread Plugs -
Major Diameter
Pitch Diameter
Up to 4 in
Up to 4 in
(26 + 3.5L) µin
(97 + 0.1L) µin
P & W LabmasterTM w/
gage blocks
Micrometer End Standards
Up to 12 in
(13 + 3L) µin
P & W LabmasterTM w/
gage blocks
Linear Indicators3 – Dial,
test & LVDT
Up to 4 in
(3.0 + 9.4L) µin + 0.6R
Gage blocks
Height Gages3
Up to 20 in
(20 to 48) in
(52 + 7.9L) µin + 0.6R
(18 + 9.6L) µin + 0.6R
Gage blocks | to 40 in |
| 3 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 3 of 18
Parameter/Equipment
Range5
CMC2, 5 (±)
Comments
Steel Rules3
Up to 72 in
Up to 10 in
(1.5 + 10L) µin + 0.6R
370 µin
Gage blocks
Vision machine
Tape Measures3
Up to 25 ft
(1.5 + 10L) µin + 0.6R
Gage blocks
Angle Indicators &
Protractors3
30°, 45°, 60°, 75°,
90°
0.03°
Angle block set
Levels – Bubble &
Precision (Vial Sensitivity)
Up to 10 degrees
7 arcsec + 0.6R
Surface plate w/ gage
blocks
Feeler/Thickness Gages3
Up to 1 in
110 µin
Micrometer
Radius Gages
Up to 2 in
370 µin
Vision machine
Fixture Gages3 –
Localized Flatness
0.002 in
40 µin
Dial indicator
Surface Plates3 –
Grades AA, A, & B
Repeatability
Flatness
0.002 in
Up to 60 DL in
(> 60 to 120) DL in
40 µin
(31 + 0.2DL) µin
(30 + 0.3DL) µin
Repeat-o-meter
Federal level systems
Optical Comparators3 –
Magnification
X – Y Linearity
Angle
10× to 250×
Up to 8 in
(> 8 to 12) in
Up to 90
o
0.014 in
160 µin
270 µin
0.1
o
Grid plate, glass master
& scale
Angle block set | to 72 in |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 4 of 18
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Auto Levels –
Level (Level Set)
Auto Level Compensation
Line of sight
Horizontal Circle Setting
Optical Micrometer Test
Through 360°
(-0.2 to 0.2) in
1.3 arcsec
1.3 arcsec
1.2 arcsec
1 arcsec
0.0009 in
Brunson 270BN
Theodolites –
Level (Level Test)
Reticle Rotation Orientation
Horizontal Collimation
Vertical Collimation
Focus Collimation (Line of
Sight)
Optical Micrometer Test
Trunnion Axis
Through 360°
(-0.2 to 0.2) in
1.3 arcsec
1.3 arcsec
1 arcsec
1 arcsec
1.2 arcsec
0.0009 in
1 arcsec
Brunson 270BN
Toolmaker’s Microscopes
Up to 2 in
150 µin
Gage blocks
III. Dimensional Testing
Parameter/Equipment
Range
CMC2, 9 (±)
Comments
Length –
1D
Up to 10 in
370 µin
Vision machine | ||
| 5 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 5 of 18
IV. Electrical – DC/Low Frequency
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
DC Voltage – Measure3
Up to 100 mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
(1 to 6) kV
(6 to 7) kV
7.8 µV/V + 0.2 µV
3.4 µV/V + 0.3 µV
3.4 µV/V + 0.5 µV
4.7 µV/V + 30 µV
4.8 µV/V + 0.5 mV
1.3 %
2.4 %
Fluke 8588A
Fluke 80K-6 & DMM
Fluke 80K-40 & DMM
DC Voltage – Generate3
(0 to 330) mV
(0 to 3.3) V
(0 to 33) V
(30 to 330) V
(100 to 1000) V
25 µV/V + 1 µV
14 µV/V + 2 µV
15 µV/V + 20 µV
22 µV/V + 150 µV
22 µV/V + 1.5 mV
Fluke 5522A
DC Current – Measure3
(0 to 10) µA
(10 to 100) µA
(0.1 to 1.0) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1.0) A
(1 to 10) A
(1 to 30) A
(1 to 50) A
29 µA/A + 0.4 nA
10 µA/A + 0.4 nA
10 µA/A + 4 nA
15 µA/A + 40 nA
58 µA/A + 1 µA
0.014 % + 0.1mA
0.024 % + 0.4 mA
0.056 % + 4.4 mA
0.31 %
Fluke 8588A
Empro shunt w/ DMM
DC Current– Generate3
Clamp-On Meters
3 –
Non-Toroidal
(0 to 330) µA
(0 to 3.3) mA
(0 to 33) mA
(0 to 330) mA
(0 to 1.1) A
(1.1 to 3) A
(0 to 11) A
(11 to 21) A
(20.5 to 1000) A
0.018 % + 0.02 µA
0.012 % + 0.05 µA
0.012 % + 0.25 µA
0.012 % + 2.5 µA
0.024 % + 40 µA
0.046 % + 40 µA
0.06 % + 500 µA
0.12 % + 750 µA
0.65 % + 0.5 A
Fluke 5522A
Fluke 5522A w/5500
coil | to 7000 V |
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 6 of 18
Parameter/Equipment
Range
CMC2, 4, 6 (±)
Comments
DC Power – Generate3
33 mV to 1020 V
(0.33 to 329.99) mA
(0.33 to 2.9999) A
(3 to 20.5) A
(0.01 to 330) W
(0.33 to 3.3) kW
(3.3 to 20.5) kW
0.032 %
0.031 %
0.085 %
Fluke 5522A
Resistance – Measure3
(0 to 1) Ω
(1 to 10) Ω
(10 to 100) Ω
(0.1 to 1) kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(0.1 to 1) MΩ
(1 to 10) MΩ
(10 to 100) MΩ
(0.1 to 1) GΩ
(1 to 10) GΩ
19 µΩ/Ω + 4.0 µΩ
11 µΩ/Ω + 14 µΩ
9.6 µΩ/Ω + 50 µΩ
9.4 µΩ/Ω + 0.5 mΩ
9.4 µΩ/Ω + 5.0 mΩ
9.6 µΩ/Ω + 50 mΩ
11 µΩ/Ω + 1 Ω
24 µΩ/Ω + 100 Ω
0.013 % + 10 kΩ
0.14 % + 1 MΩ
0.14 % + 10 MΩ
Fluke 8588A
Resistance – Generate3
(0 to 11) Ω
(11 to 33) Ω
(33 to 110) Ω
110 Ω to 1.1 kΩ
(1.1 to 11) kΩ
(11 to 110) kΩ
110 kΩ to 1.1 MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
(330 to 1100) MΩ
49 µΩ/Ω + 0.001 Ω
37 µΩ/Ω + 0.0015 Ω
34 µΩ/Ω + 0.0014 Ω
34 µΩ/Ω + 0.002 Ω
34 µΩ/Ω + 0.02 Ω
34 µΩ/Ω + 0.2 Ω
39 µΩ/Ω + 2 Ω
73 µΩ/Ω + 30 Ω
0.016 % + 50 Ω
0.03 % + 2.5 kΩ
0.06 % + 3 kΩ
0.36 % + 100 kΩ
1.8 % + 500 kΩ
Fluke 5522A
Insulation Resistance –
Generate3
1 kΩ to 100 MΩ
100 MΩ to 100 GΩ
0.31 %
0.7 %
IET fixed resistor box | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 7 of 18
Parameter/Equipment
Frequency
CMC2, 4, 6 (±)
Comments
Capacitance – Generate3
(220 to 399.9) pF
(0.4 to 1.0999) nF
(1.1 to 3.2999) nF
(3.3 to 10.9999) nF
(11 to 109.999) nF
(110 to 329.999) nF
(0.33 to 1.099 99) µF
(1.1 to 3.299 99) µF
(3.3 to 10.9999) µF
(11 to 32.9999) µF
(33 to 109.999) µF
(110 to 329.999) µF
(0.33 to 1.099 99) mF
(1.1 to 3.299 99) mF
(3.3 to 10.9999) mF
(11 to 32.9999) mF
(33 to 110) mF
(10 to 10 000) Hz
(10 to 10 000) Hz
(10 to 3000) Hz
(10 to 1000) Hz
(10 to 1000) Hz
(10 to 1000) Hz
(10 to 600) Hz
(10 to 300) Hz
(10 to 150) Hz
(10 to 120) Hz
(10 to 80) Hz
(0 to 50) Hz
(0 to 20) Hz
(0 to 6) Hz
(0 to 2) Hz
(0 to 0.6) Hz
(0 to 0.2) Hz
0.88 % + 10 pF
0.6 % + 0.01 nF
0.6 % + 0.01 nF
0.31 % + 0.1 nF
0.31 % + 0.1 nF
0.31 % + 0.3 nF
0.31 % + 1 nF
0.31 % + 3 nF
0.31 % + 10 nF
0.49 % + 30 nF
0.55 % + 100 nF
0.55 % + 300 nF
0.55 % + 1 µF
0.55 % + 3 µF
0.56 % + 10 µF
0.91 % + 30 µF
1.4 % + 100 µF
Fluke 5522A
AC Voltage – Generate3
(0 to 33) mV
(33 to 330) mV
(0.33 to 3.3) V
(3.3 to 33) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
0.096 % + 6 µV
0.022 % + 6 µV
0.026 % + 6 µV
0.12 % + 6 µV
0.42 % + 12 µV
0.96 % + 50 µV
0.036 % + 8 µV
0.018 % + 8 µV
0.02 % + 8 µV
0.042 % + 8 µV
0.096 % + 32 µV
0.24 % + 70 µV
0.036 % + 50 µV
0.019 % + 60 µV
0.023 % + 60 µV
0.036 % + 50 µV
0.084 % + 130 µV
0.29 % + 600 µV
0.036 % + 650 µV
0.019 % + 600 µV
0.029 % + 600 µV
0.042 % + 600 µV
0.11 % + 1.6 mV
Fluke 5522A | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 8 of 18
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Voltage – Generate3
(cont)
(33 to 330) V
(330 to 1020) V
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 10 kHz
0.023 % + 2 mV
0.025 % + 6 mV
0.03 % + 6 mV
0.036 % + 6 mV
0.24 % + 50 mV
0.036 % + 10 mV
Fluke 5522A
AC Voltage – Measure3
(0 to 10) mV
(10 to 100) mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
(0.3 to 1) MHz
0.034 % + 1.1 µV
0.041 % + 1.1 µV
0.042 % + 1.1 µV
0.031 % + 1.1 µV
1.1 % + 4 µV
2.1 % + 4 µV
0.01 % + 0.5 µV
0.014 % + 0.4 µV
0.024 % + 1 µV
0.054 % + 5 µV
0.22 % + 30 µV
1.2 % + 0.1 mV
0.008 % + 5 µV
0.013 % + 5 µV
0.024 % + 10 µV
0.054 % + 50 µV
0.22 % + 0.3 mV
1.1 % + 1 mV
0.008 % + 50 µV
0.013 % + 50 µV
0.024 % + 0.1 mV
0.054 % + 0.5 mV
0.22 % + 3 mV
1.1 % + 10 mV
0.016 % + 0.5mV
0.017 % + 0.5mV
0.027 % + 1 mV
0.061 % + 5 mV
0.38 % + 50 mV
1.2 % + 0.5 V
Fluke 8588A | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 9 of 18
Parameter/Range
Frequency
CMC2, 4, 6 (±)
Comments
AC Voltage – Measure3
(cont)
(100 to 1000) V
(1 to 6) kV
(6 to 10) kV
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(50 to 60) Hz
(50 to 60) Hz
0.012 % + 25 mV
0.012 % + 25 mV
0.025 % + 25 mV
0.06 % + 0.1 V
1.6 %
6 %
Fluke 8588A
DMM with Fluke 80K6
HH probe
DMM with Fluke
80K40 HV probe
AC Current – Generate3
(0 to 0.33) mA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
0.24 % + 0.1 µA
0.18 % + 0.1 µA
0.15 % + 0.1 µA
0.36 % + 0.15 µA
0.96 % + 0.2 µA
2 % + 0.4 µA
0.24 % + 0.15 µA
0.16 % + 0.15 µA
0.13 % + 0.15 µA
0.25 % + 0.2 µA
0.6 % + 0.3 µA
1.2 % + 0.6 µA
0.22 % + 2 µA
0.11 % + 2 µA
0.05 % + 2 µA
0.097 % + 2 µA
0.24 % + 3 µA
0.48 % + 4 µA
0.22 % + 20 µA
0.11 % + 20 µA
0.05 % + 20 µA
0.12 % + 50 µA
0.24 % + 100 µA
0.48 % + 200 µA
Fluke 5522A | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 10 of 18
Parameter/Range
Frequency
CMC2, 4, 7 (±)
Comments
AC Current – Generate3
(cont)
(0.33 to 1.1) A
(1.1 to 3) A
(3 to 11) A
(11 to 20.5) A
Clamp-On Meters
3–
(10 to 150) A
Toroidal
Non-Toroidal
(150 to 1025) A
Toroidal
Non-Toroidal
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
45 Hz to 1 kHz
(1 to 5) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
(45 to 65) Hz
(65 to 440) Hz
0.22 % + 100 µA
0.06 % + 100 µA
0.72 % + 1 mA
3 % + 5 mA
0.22 % + 100 µA
0.073 % + 100 µA
0.72 % + 1 mA
3 % + 5 mA
0.12 % + 2 mA
3.6 % + 2 mA
0.18 % + 5 mA
3.6 % + 5 mA
0.49 % + 0.025 A
1 % + 0.027 A
0.76 % + 0.25 A
1.3 % + 0.25 A
0.49 % + 0.09 A
1 % + 0.1 A
0.76 % + 0.9 A
1.3 % + 0.9 A
Fluke 5522A
Fluke 5522A w/ 5500
coil | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 11 of 18
Parameter/Range
Frequency
CMC2, 4, 7 (±)
Comments
AC Current – Measure3
(0 to 10) µA
(10 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
(0.1 to 1) A
(1 to 10) A
(10 to 30) A
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
1 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
10 Hz to 2 kHz
(2 to 10) kHz
10 Hz to 2 kHz
(2 to 10) kHz
0.21 % + 2.5 nA
0.21 % + 2.5 nA
0.21 % + 2.5 nA
0.029 % + 5 nA
0.054 % + 5 nA
0.075 % + 5 nA
0.41 % + 10 nA
0.029 % + 50 nA
0.054 % + 50 nA
0.075 % + 50 nA
0.41 % + 0.1 µA
0.029 % + 0.5 µA
0.054 % + 0.5 µA
0.075 % + 0.5 µA
0.41 % + 1 µA
0.029 % + 5 µA
0.053 % + 5 µA
0.075 % + 5 µA
0.031 % + 0.1 mA
0.056 % + 0.1 mA
0.08 % + 0.1 mA
0.085 % + 0.5 mA
0.085 % + 0.5 mA
0.085 % + 12 mA
0.13 % + 12 mA
Fluke 8588A | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 12 of 18
Parameter/Equipment
Range
CMC 2, 4 (±)
Comments
AC Power – Generate3
(45 to 65) Hz; PF=1
(33 to 330) mV Range
(3.3 to 8.99) mA
(9 to 32.99) mA
(33 to 89.99) mA
(90 to 329.99) mA
(0.33 to 0.8999) A
(0.9 to 2.1999) A
(2.2 to 4.4999) A
(4.5 to 20.5) A
(45 to 65) Hz; PF=1
330 mV to 1020 V Range
(3.3 to 8.99) mA
(9 to 32.99) mA
(33 to 89.99) mA
(90 to 329.99) mA
(0.33 to 0.8999) A
(0.9 to 2.1999) A
(2.2 to 4.4999) A
(4.5 to 20.5) A
110 μW to 3 mW
(3 to 11) mW
(1.1 to 30) mW
(3 to 110) mW
(11 to 300) mW
(30 to 730) mW
73 mW to 1.5 W
150 mW to 6.8 W
1.1 mW to 9 W
3 mW to 33 W
11 mW to 90 W
30 mW to 330 W
110 mW to 900 W
300 mW to 2200 W
730 mW to 4500 W
(1.5 to 20.9) kW
0.17 %
0.12 %
0.17 %
0.12 %
0.16 %
0.14 %
0.16 %
0.14 %
0.15 %
0.1 %
0.15 %
0.1 %
0.14 %
0.11 %
0.15 %
0.12 %
Fluke 5522A | ||
| 13 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 13 of 18
Thermocouple
Simulation & Measure3 –
Type B
Type E
Type J
Type K
Type N
Type R
Type S
Type T
(600 to 800) °C
(800 to 1820) °C
(-250 to -100) °C
(-100 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to 1000) °C
(1000 to 1372) °C
(-200 to -100) °C
(-100 to 410) °C
(410 to 1300) °C
(0 to 250) °C
(250 to 1000) °C
(1000 to 1767) °C
(0 to 250) °C
(250 to 1400) °C
(1400 to 1767) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 400) °C
0.53 °C
0.43 °C
0.61 °C
0.21 °C
0.26 °C
0.33 °C
0.21 °C
0.28 °C
0.40 °C
0.32 °C
0.48 °C
0.50 °C
0.29 °C
0.35 °C
0.70 °C
0.42 °C
0.50 °C
0.58 °C
0.46 °C
0.57 °C
0.76 °C
0.30 °C
0.21 °C
Fluke 5522A
Electrical Calibration of
RTD’s3 –
Generate
Measure
(-200 to 200) °C
(200 to 600) °C
(600 to 850) °C
(-200 to 200) °C
(200 to 600) °C
(600 to 850) °C
0.19 °C
0.31 °C
0.43 °C
0.19 °C
0.31 °C
0.43 °C
Beamex MC2-MF | to 1820 °C |
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 14 of 18
Parameter/Equipment
Range
CMC 2, 4, 5 (±)
Comments
Oscilloscopes3 –
Square Wave Signal:
50 Ω Load @ 1 kHz
1 MΩ Load @ 1 kHz
DC Volt Amplitude:
50 Ω Load
1 MΩ Load
Level Sine Wave:
Frequency
Amplitude
Flatness (Bandwidth)
Time Markers:
Into a 50 Ω Load
Rise Time:
1 kHz to 2 MHz
(2 to 10) MHz
1 mV to 6.6 V
pk-pk
1 mV to 130 Vpk-pk
(0 to 6.6) V
(0 to 130) V
Up to 1100 MHz
50 kHz Reference
50 kHz to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
(300 to 1100) MHz
Up to 100 MHz
(100 to 300) MHz
(300 to 600) MHz
(300 to 1100) MHz
5 s to 50 ms
20 ms to 2 ns
≤ 300 ps
≤ 350 ps
0.31 % + 40 µV
0.14 % + 40 µV
0.3 % + 40 µV
0.06 % + 40 µV
3.3 µHz/Hz
2.4 % + 300 µV
4.2 % + 300 µV
4.8 % + 300 µV
7.2 % + 300 µV
8.4 % + 300 µV
1.8 % + 100 µV
2.4 % + 100 µV
4.8 % + 100 µV
6 % + 100 µV
(30 + 1000t) µs/s
3.5 µs/s
130 ps
130 ps
Fluke 5522A w/
SC1100
V. Fluid Quantities
Parameter/Equipment
Range
CMC2 ,5, 6 (±)
Comments
Fume Hoods – Air
Velocity Only
3
(20 to 100) ft/min
(100 to 200) ft/min
5.2 ft/min
4.1 %
Anemometer
Viscosity Meters3
1 cP
5 cP
50 cP
100 cP
500 cP
0.2 % + 0.6R
0.2 % + 0.6R
0.26 % + 0.6R
0.26 % + 0.6R
0.32 % + 0.6R
Standard viscosity
solutions w/ bath | ||
| 15 | Gravimetric method | - | See scope document |
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 16 of 18
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Torque – Measure3 –
Wrenches – Click, Dial,
Adjustable, Screwdrivers
5 lbf∙in to 600 lbf∙ft
0.65 %
CDI Suretest 5000-
ST
Rotary Torque– Measure3
– Pneumatic, DC, Pulse
(0 to 180) N∙m
1.3 % Full Scale
Crane-Torquestar w/
rotary transducers
Pressure – Measure &
Measuring Equipment3
Pneumatic
Hydraulic
(0 to 1) in∙H
2O
(0 to 4) in∙H
2O
(0.01 to 30) psig
Up to 300 psig
(30 to 300) psig
(300 to 1000) psig
(1000 to 10 000) psig
Up to 100 psig
(> 100 to 10 000) psig
0.002 in∙H2O
0.025 in∙H
2O
0.021 psi
0.09 psi + 0.025 %
0.21 psi
0.7 psi
7 psi
0.05 %
0.06 %
Heise HM2-1
Dwyer 475
Beamex MC2-MF
Beamex MC2-MF
w/EXT20C
Druck DPI-104
Deadweight tester
Atmospheric Pressure –
Measure & Measuring
Equipment (Vacuum)
3
(0.01 to 28.5) in∙Hg
Up to 10 Torr
(10 to 100) Torr
0.02 in∙Hg
0.7 % + 0.001 Torr
0.64 % + 0.01 Torr
Beamex MC2-
IPM2C
MKS pressure
transducers
Speed – Measure3
Optic/Non-contact:
RPM
Totalizer/Rate Meters
Contact:
RPM
Totalizer/Rate Meters
(6 to 100 000) rpm
(2 to 3300) fpm
(6 to 20 000) rpm
(2 to 3300) fpm
0.017 %
0.017 %
0.22 %
0.22 %
Monarch PLT200
Shimpo 105A | ||
| 17 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 17 of 18
Parameter/Equipment
Range
CMC 2, 5, 6 (±)
Comments
Totalize Meters –
Distance Measure
Mechanical
Counter/Totalizers3
Up to 200 ft
Up to 999 999 counts
0.64 %
0.02 % + 0.6R
Monarch PLT200 w/
10cm wheel
Speed/RPM– Measuring
Equipment
(2.5 to 100 000) RPM
0.000 24 % + 0.6R
Keysight 33500B
VII. Thermodynamics
Parameter/Equipment
Range
CMC 2, 7 (±)
Comments
Relative Humidity –
Measure3
(10 to 80) % RH
1.5 % RH
Rotronic HP22A w/ HC2
Probe
Temperature – Measure3
(-196 to 420) °C
0.06 °C
Fluke 1524 w/5615-12
Probe
Temperature –
Measuring Equipment
3
(-45 to 140) °C
(-15 to 350) °C
0.18 °C
0.15 °C
Fluke 9170
Fluke 9009 w/ Ext Probe
Infrared Thermometry –
Measuring Equipment3
35 °C
(35 to 100) °C
(100 to 200) °C
(200 to 350) °C
(350 to 500) °C
0.86 °C
1 °C
1.2 °C
1.7 °C
2.3 °C
Fluke 4181
Spectral band
(8 to 14) µm
Emissivity 0.95 | to 200 ft |
| 18 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 18 of 18
VIII. Time & Frequency
Parameter/Equipment
Range
CMC2 (±)
Comments
Timers & Stopwatches3
(1 to 3600) s
0.2 s
Monarch PLT 200
Frequency – Measure3
Up to 350 MHz
0.06 µHz/Hz
Keysight 53210A
Frequency – Measuring
Equipment3
0.01 Hz to 2 MHz
3.1 parts in 106 + 5 µHz
Fluke 5522A
______________________________________________________________
1 This laboratory offers commercial calibration and field calibration services, where noted.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavi or of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
5 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches;
R is the numerical value of the resolution of the device, DL is the diagonal length of the device in inches,
and t is time in seconds.
6 In the statement of CMC, percentages are percent of reading, unless otherwise indicated.
7 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
8 This scope meets A2LA’s P112 Flexible Scope Policy.
9 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for
the types of dimensional tests listed above and is considered equivalent to that of a calibration. | 1 to 3600 s |
| 19 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.