CROSS TECHNOLOGIES, INC - LEXINGTON

354 Riverchase Way, 29072, Lexington, SC, United States

Visit website
A2LA 1741.12ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
19
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 19 scope lines.

A2LA certificate 1741.12 · 19 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 1 of 18 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 CROSS TECHNOLOGIES, INC 354 Riverchase Way Lexington, SC 29072 Connie Foster Phone: 800 327 7727 CALIBRATION Valid To: September 30, 2026 Certificate Number: 1741.12 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 8: I. Chemical Parameter/Equipment Range CMC2, 5 (±) Comments pH Meters3 – Fixed Points 4 pH 7 pH 10 pH 0.03 pH 0.03 pH 0.04 pH Standard pH solutions Conductivity Meters3 10 µS/cm 100 µS/cm 1000 µS/cm 1413 µS/cm 10 000 µS/cm 0.56 µS/cm 2.2 µS/cm 5.2 µS/cm 4.7 µS/cm 46 µS/cm Standard conductivity solutions Refractometers3 (5, 10, 25, 40, 60) % Brix 0.033 % + 0.6R Brix Sucrose solutions II. Dimensional Parameter/Equipment Range CMC2, 5 (±) Comments Pin Gage3 – Class Z & Class ZZ Up to 1 in 110 µin Micrometer
to 1 in
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 2 of 18 Parameter/Equipment Range CMC2, 5 (±) Comments Calipers3 Up to 40 in (4.5 + 9.9L) µin + 0.6R Gage blocks Micrometers3 (Outside & Depth) Up to 40 in (4.5 + 9.9L) µin + 0.6R Gage blocks Inside Micrometers3 Up to 40 in (4.5 + 9.9L) µin + 0.6R Gage blocks Thickness Gages3 Up to 4 in (6.4 + 3.1L) µin + 0.6R Gage blocks Coating Thickness Gages3 Up to 63 mils 0.1 mils Coating thickness standards Cylindrical Measure – Plain Rings Pins, Plain Plugs, Discs, Spheres – External Diameter Up to 10 in Up to 10 in (17 + 4.6L) µin (13 + 2.9L) µin P & W Labmaster TM w/ XX master rings P & W LabmasterTM w/ gage blocks Thread Plugs - Major Diameter Pitch Diameter Up to 4 in Up to 4 in (26 + 3.5L) µin (97 + 0.1L) µin P & W LabmasterTM w/ gage blocks Micrometer End Standards Up to 12 in (13 + 3L) µin P & W LabmasterTM w/ gage blocks Linear Indicators3 – Dial, test & LVDT Up to 4 in (3.0 + 9.4L) µin + 0.6R Gage blocks Height Gages3 Up to 20 in (20 to 48) in (52 + 7.9L) µin + 0.6R (18 + 9.6L) µin + 0.6R Gage blocks
to 40 in
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 3 of 18 Parameter/Equipment Range5 CMC2, 5 (±) Comments Steel Rules3 Up to 72 in Up to 10 in (1.5 + 10L) µin + 0.6R 370 µin Gage blocks Vision machine Tape Measures3 Up to 25 ft (1.5 + 10L) µin + 0.6R Gage blocks Angle Indicators & Protractors3 30°, 45°, 60°, 75°, 90° 0.03° Angle block set Levels – Bubble & Precision (Vial Sensitivity) Up to 10 degrees 7 arcsec + 0.6R Surface plate w/ gage blocks Feeler/Thickness Gages3 Up to 1 in 110 µin Micrometer Radius Gages Up to 2 in 370 µin Vision machine Fixture Gages3 – Localized Flatness 0.002 in 40 µin Dial indicator Surface Plates3 – Grades AA, A, & B Repeatability Flatness 0.002 in Up to 60 DL in (> 60 to 120) DL in 40 µin (31 + 0.2DL) µin (30 + 0.3DL) µin Repeat-o-meter Federal level systems Optical Comparators3 – Magnification X – Y Linearity Angle 10× to 250× Up to 8 in (> 8 to 12) in Up to 90 o 0.014 in 160 µin 270 µin 0.1 o Grid plate, glass master & scale Angle block set
to 72 in
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 4 of 18 Parameter/Equipment Range CMC2, 5 (±) Comments Auto Levels – Level (Level Set) Auto Level Compensation Line of sight Horizontal Circle Setting Optical Micrometer Test Through 360° (-0.2 to 0.2) in 1.3 arcsec 1.3 arcsec 1.2 arcsec 1 arcsec 0.0009 in Brunson 270BN Theodolites – Level (Level Test) Reticle Rotation Orientation Horizontal Collimation Vertical Collimation Focus Collimation (Line of Sight) Optical Micrometer Test Trunnion Axis Through 360° (-0.2 to 0.2) in 1.3 arcsec 1.3 arcsec 1 arcsec 1 arcsec 1.2 arcsec 0.0009 in 1 arcsec Brunson 270BN Toolmaker’s Microscopes Up to 2 in 150 µin Gage blocks III. Dimensional Testing Parameter/Equipment Range CMC2, 9 (±) Comments Length – 1D Up to 10 in 370 µin Vision machine
5--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 5 of 18 IV. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 4, 6 (±) Comments DC Voltage – Measure3 Up to 100 mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 1000) V (1 to 6) kV (6 to 7) kV 7.8 µV/V + 0.2 µV 3.4 µV/V + 0.3 µV 3.4 µV/V + 0.5 µV 4.7 µV/V + 30 µV 4.8 µV/V + 0.5 mV 1.3 % 2.4 % Fluke 8588A Fluke 80K-6 & DMM Fluke 80K-40 & DMM DC Voltage – Generate3 (0 to 330) mV (0 to 3.3) V (0 to 33) V (30 to 330) V (100 to 1000) V 25 µV/V + 1 µV 14 µV/V + 2 µV 15 µV/V + 20 µV 22 µV/V + 150 µV 22 µV/V + 1.5 mV Fluke 5522A DC Current – Measure3 (0 to 10) µA (10 to 100) µA (0.1 to 1.0) mA (1 to 10) mA (10 to 100) mA (0.1 to 1.0) A (1 to 10) A (1 to 30) A (1 to 50) A 29 µA/A + 0.4 nA 10 µA/A + 0.4 nA 10 µA/A + 4 nA 15 µA/A + 40 nA 58 µA/A + 1 µA 0.014 % + 0.1mA 0.024 % + 0.4 mA 0.056 % + 4.4 mA 0.31 % Fluke 8588A Empro shunt w/ DMM DC Current– Generate3 Clamp-On Meters 3 – Non-Toroidal (0 to 330) µA (0 to 3.3) mA (0 to 33) mA (0 to 330) mA (0 to 1.1) A (1.1 to 3) A (0 to 11) A (11 to 21) A (20.5 to 1000) A 0.018 % + 0.02 µA 0.012 % + 0.05 µA 0.012 % + 0.25 µA 0.012 % + 2.5 µA 0.024 % + 40 µA 0.046 % + 40 µA 0.06 % + 500 µA 0.12 % + 750 µA 0.65 % + 0.5 A Fluke 5522A Fluke 5522A w/5500 coil
to 7000 V
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 6 of 18 Parameter/Equipment Range CMC2, 4, 6 (±) Comments DC Power – Generate3 33 mV to 1020 V (0.33 to 329.99) mA (0.33 to 2.9999) A (3 to 20.5) A (0.01 to 330) W (0.33 to 3.3) kW (3.3 to 20.5) kW 0.032 % 0.031 % 0.085 % Fluke 5522A Resistance – Measure3 (0 to 1) Ω (1 to 10) Ω (10 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ (0.1 to 1) GΩ (1 to 10) GΩ 19 µΩ/Ω + 4.0 µΩ 11 µΩ/Ω + 14 µΩ 9.6 µΩ/Ω + 50 µΩ 9.4 µΩ/Ω + 0.5 mΩ 9.4 µΩ/Ω + 5.0 mΩ 9.6 µΩ/Ω + 50 mΩ 11 µΩ/Ω + 1 Ω 24 µΩ/Ω + 100 Ω 0.013 % + 10 kΩ 0.14 % + 1 MΩ 0.14 % + 10 MΩ Fluke 8588A Resistance – Generate3 (0 to 11) Ω (11 to 33) Ω (33 to 110) Ω 110 Ω to 1.1 kΩ (1.1 to 11) kΩ (11 to 110) kΩ 110 kΩ to 1.1 MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (330 to 1100) MΩ 49 µΩ/Ω + 0.001 Ω 37 µΩ/Ω + 0.0015 Ω 34 µΩ/Ω + 0.0014 Ω 34 µΩ/Ω + 0.002 Ω 34 µΩ/Ω + 0.02 Ω 34 µΩ/Ω + 0.2 Ω 39 µΩ/Ω + 2 Ω 73 µΩ/Ω + 30 Ω 0.016 % + 50 Ω 0.03 % + 2.5 kΩ 0.06 % + 3 kΩ 0.36 % + 100 kΩ 1.8 % + 500 kΩ Fluke 5522A Insulation Resistance – Generate3 1 kΩ to 100 MΩ 100 MΩ to 100 GΩ 0.31 % 0.7 % IET fixed resistor box
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 7 of 18 Parameter/Equipment Frequency CMC2, 4, 6 (±) Comments Capacitance – Generate3 (220 to 399.9) pF (0.4 to 1.0999) nF (1.1 to 3.2999) nF (3.3 to 10.9999) nF (11 to 109.999) nF (110 to 329.999) nF (0.33 to 1.099 99) µF (1.1 to 3.299 99) µF (3.3 to 10.9999) µF (11 to 32.9999) µF (33 to 109.999) µF (110 to 329.999) µF (0.33 to 1.099 99) mF (1.1 to 3.299 99) mF (3.3 to 10.9999) mF (11 to 32.9999) mF (33 to 110) mF (10 to 10 000) Hz (10 to 10 000) Hz (10 to 3000) Hz (10 to 1000) Hz (10 to 1000) Hz (10 to 1000) Hz (10 to 600) Hz (10 to 300) Hz (10 to 150) Hz (10 to 120) Hz (10 to 80) Hz (0 to 50) Hz (0 to 20) Hz (0 to 6) Hz (0 to 2) Hz (0 to 0.6) Hz (0 to 0.2) Hz 0.88 % + 10 pF 0.6 % + 0.01 nF 0.6 % + 0.01 nF 0.31 % + 0.1 nF 0.31 % + 0.1 nF 0.31 % + 0.3 nF 0.31 % + 1 nF 0.31 % + 3 nF 0.31 % + 10 nF 0.49 % + 30 nF 0.55 % + 100 nF 0.55 % + 300 nF 0.55 % + 1 µF 0.55 % + 3 µF 0.56 % + 10 µF 0.91 % + 30 µF 1.4 % + 100 µF Fluke 5522A AC Voltage – Generate3 (0 to 33) mV (33 to 330) mV (0.33 to 3.3) V (3.3 to 33) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 0.096 % + 6 µV 0.022 % + 6 µV 0.026 % + 6 µV 0.12 % + 6 µV 0.42 % + 12 µV 0.96 % + 50 µV 0.036 % + 8 µV 0.018 % + 8 µV 0.02 % + 8 µV 0.042 % + 8 µV 0.096 % + 32 µV 0.24 % + 70 µV 0.036 % + 50 µV 0.019 % + 60 µV 0.023 % + 60 µV 0.036 % + 50 µV 0.084 % + 130 µV 0.29 % + 600 µV 0.036 % + 650 µV 0.019 % + 600 µV 0.029 % + 600 µV 0.042 % + 600 µV 0.11 % + 1.6 mV Fluke 5522A
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 8 of 18 Parameter/Range Frequency CMC2, 4 (±) Comments AC Voltage – Generate3 (cont) (33 to 330) V (330 to 1020) V 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 10 kHz 0.023 % + 2 mV 0.025 % + 6 mV 0.03 % + 6 mV 0.036 % + 6 mV 0.24 % + 50 mV 0.036 % + 10 mV Fluke 5522A AC Voltage – Measure3 (0 to 10) mV (10 to 100) mV (0.1 to 1) V (1 to 10) V (10 to 100) V 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (100 to 300) kHz (0.3 to 1) MHz 0.034 % + 1.1 µV 0.041 % + 1.1 µV 0.042 % + 1.1 µV 0.031 % + 1.1 µV 1.1 % + 4 µV 2.1 % + 4 µV 0.01 % + 0.5 µV 0.014 % + 0.4 µV 0.024 % + 1 µV 0.054 % + 5 µV 0.22 % + 30 µV 1.2 % + 0.1 mV 0.008 % + 5 µV 0.013 % + 5 µV 0.024 % + 10 µV 0.054 % + 50 µV 0.22 % + 0.3 mV 1.1 % + 1 mV 0.008 % + 50 µV 0.013 % + 50 µV 0.024 % + 0.1 mV 0.054 % + 0.5 mV 0.22 % + 3 mV 1.1 % + 10 mV 0.016 % + 0.5mV 0.017 % + 0.5mV 0.027 % + 1 mV 0.061 % + 5 mV 0.38 % + 50 mV 1.2 % + 0.5 V Fluke 8588A
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 9 of 18 Parameter/Range Frequency CMC2, 4, 6 (±) Comments AC Voltage – Measure3 (cont) (100 to 1000) V (1 to 6) kV (6 to 10) kV 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz (50 to 60) Hz (50 to 60) Hz 0.012 % + 25 mV 0.012 % + 25 mV 0.025 % + 25 mV 0.06 % + 0.1 V 1.6 % 6 % Fluke 8588A DMM with Fluke 80K6 HH probe DMM with Fluke 80K40 HV probe AC Current – Generate3 (0 to 0.33) mA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz (10 to 20) Hz (20 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 30) kHz 0.24 % + 0.1 µA 0.18 % + 0.1 µA 0.15 % + 0.1 µA 0.36 % + 0.15 µA 0.96 % + 0.2 µA 2 % + 0.4 µA 0.24 % + 0.15 µA 0.16 % + 0.15 µA 0.13 % + 0.15 µA 0.25 % + 0.2 µA 0.6 % + 0.3 µA 1.2 % + 0.6 µA 0.22 % + 2 µA 0.11 % + 2 µA 0.05 % + 2 µA 0.097 % + 2 µA 0.24 % + 3 µA 0.48 % + 4 µA 0.22 % + 20 µA 0.11 % + 20 µA 0.05 % + 20 µA 0.12 % + 50 µA 0.24 % + 100 µA 0.48 % + 200 µA Fluke 5522A
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 10 of 18 Parameter/Range Frequency CMC2, 4, 7 (±) Comments AC Current – Generate3 (cont) (0.33 to 1.1) A (1.1 to 3) A (3 to 11) A (11 to 20.5) A Clamp-On Meters 3– (10 to 150) A Toroidal Non-Toroidal (150 to 1025) A Toroidal Non-Toroidal (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 45) Hz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 45 Hz to 1 kHz (1 to 5) kHz 45 Hz to 1 kHz (1 to 5) kHz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz (45 to 65) Hz (65 to 440) Hz 0.22 % + 100 µA 0.06 % + 100 µA 0.72 % + 1 mA 3 % + 5 mA 0.22 % + 100 µA 0.073 % + 100 µA 0.72 % + 1 mA 3 % + 5 mA 0.12 % + 2 mA 3.6 % + 2 mA 0.18 % + 5 mA 3.6 % + 5 mA 0.49 % + 0.025 A 1 % + 0.027 A 0.76 % + 0.25 A 1.3 % + 0.25 A 0.49 % + 0.09 A 1 % + 0.1 A 0.76 % + 0.9 A 1.3 % + 0.9 A Fluke 5522A Fluke 5522A w/ 5500 coil
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 11 of 18 Parameter/Range Frequency CMC2, 4, 7 (±) Comments AC Current – Measure3 (0 to 10) µA (10 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A (1 to 10) A (10 to 30) A 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz (30 to 100) kHz 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz 1 Hz to 2 kHz (2 to 10) kHz (10 to 30) kHz 10 Hz to 2 kHz (2 to 10) kHz 10 Hz to 2 kHz (2 to 10) kHz 0.21 % + 2.5 nA 0.21 % + 2.5 nA 0.21 % + 2.5 nA 0.029 % + 5 nA 0.054 % + 5 nA 0.075 % + 5 nA 0.41 % + 10 nA 0.029 % + 50 nA 0.054 % + 50 nA 0.075 % + 50 nA 0.41 % + 0.1 µA 0.029 % + 0.5 µA 0.054 % + 0.5 µA 0.075 % + 0.5 µA 0.41 % + 1 µA 0.029 % + 5 µA 0.053 % + 5 µA 0.075 % + 5 µA 0.031 % + 0.1 mA 0.056 % + 0.1 mA 0.08 % + 0.1 mA 0.085 % + 0.5 mA 0.085 % + 0.5 mA 0.085 % + 12 mA 0.13 % + 12 mA Fluke 8588A
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 12 of 18 Parameter/Equipment Range CMC 2, 4 (±) Comments AC Power – Generate3 (45 to 65) Hz; PF=1 (33 to 330) mV Range (3.3 to 8.99) mA (9 to 32.99) mA (33 to 89.99) mA (90 to 329.99) mA (0.33 to 0.8999) A (0.9 to 2.1999) A (2.2 to 4.4999) A (4.5 to 20.5) A (45 to 65) Hz; PF=1 330 mV to 1020 V Range (3.3 to 8.99) mA (9 to 32.99) mA (33 to 89.99) mA (90 to 329.99) mA (0.33 to 0.8999) A (0.9 to 2.1999) A (2.2 to 4.4999) A (4.5 to 20.5) A 110 μW to 3 mW (3 to 11) mW (1.1 to 30) mW (3 to 110) mW (11 to 300) mW (30 to 730) mW 73 mW to 1.5 W 150 mW to 6.8 W 1.1 mW to 9 W 3 mW to 33 W 11 mW to 90 W 30 mW to 330 W 110 mW to 900 W 300 mW to 2200 W 730 mW to 4500 W (1.5 to 20.9) kW 0.17 % 0.12 % 0.17 % 0.12 % 0.16 % 0.14 % 0.16 % 0.14 % 0.15 % 0.1 % 0.15 % 0.1 % 0.14 % 0.11 % 0.15 % 0.12 % Fluke 5522A
13--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 13 of 18 Thermocouple Simulation & Measure3 – Type B Type E Type J Type K Type N Type R Type S Type T (600 to 800) °C (800 to 1820) °C (-250 to -100) °C (-100 to 650) °C (650 to 1000) °C (-210 to -100) °C (-100 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to 1000) °C (1000 to 1372) °C (-200 to -100) °C (-100 to 410) °C (410 to 1300) °C (0 to 250) °C (250 to 1000) °C (1000 to 1767) °C (0 to 250) °C (250 to 1400) °C (1400 to 1767) °C (-250 to -150) °C (-150 to 0) °C (0 to 400) °C 0.53 °C 0.43 °C 0.61 °C 0.21 °C 0.26 °C 0.33 °C 0.21 °C 0.28 °C 0.40 °C 0.32 °C 0.48 °C 0.50 °C 0.29 °C 0.35 °C 0.70 °C 0.42 °C 0.50 °C 0.58 °C 0.46 °C 0.57 °C 0.76 °C 0.30 °C 0.21 °C Fluke 5522A Electrical Calibration of RTD’s3 – Generate Measure (-200 to 200) °C (200 to 600) °C (600 to 850) °C (-200 to 200) °C (200 to 600) °C (600 to 850) °C 0.19 °C 0.31 °C 0.43 °C 0.19 °C 0.31 °C 0.43 °C Beamex MC2-MF
to 1820 °C
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 14 of 18 Parameter/Equipment Range CMC 2, 4, 5 (±) Comments Oscilloscopes3 – Square Wave Signal: 50 Ω Load @ 1 kHz 1 MΩ Load @ 1 kHz DC Volt Amplitude: 50 Ω Load 1 MΩ Load Level Sine Wave: Frequency Amplitude Flatness (Bandwidth) Time Markers: Into a 50 Ω Load Rise Time: 1 kHz to 2 MHz (2 to 10) MHz 1 mV to 6.6 V pk-pk 1 mV to 130 Vpk-pk (0 to 6.6) V (0 to 130) V Up to 1100 MHz 50 kHz Reference 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (300 to 1100) MHz Up to 100 MHz (100 to 300) MHz (300 to 600) MHz (300 to 1100) MHz 5 s to 50 ms 20 ms to 2 ns ≤ 300 ps ≤ 350 ps 0.31 % + 40 µV 0.14 % + 40 µV 0.3 % + 40 µV 0.06 % + 40 µV 3.3 µHz/Hz 2.4 % + 300 µV 4.2 % + 300 µV 4.8 % + 300 µV 7.2 % + 300 µV 8.4 % + 300 µV 1.8 % + 100 µV 2.4 % + 100 µV 4.8 % + 100 µV 6 % + 100 µV (30 + 1000t) µs/s 3.5 µs/s 130 ps 130 ps Fluke 5522A w/ SC1100 V. Fluid Quantities Parameter/Equipment Range CMC2 ,5, 6 (±) Comments Fume Hoods – Air Velocity Only 3 (20 to 100) ft/min (100 to 200) ft/min 5.2 ft/min 4.1 % Anemometer Viscosity Meters3 1 cP 5 cP 50 cP 100 cP 500 cP 0.2 % + 0.6R 0.2 % + 0.6R 0.26 % + 0.6R 0.26 % + 0.6R 0.32 % + 0.6R Standard viscosity solutions w/ bath
15Gravimetric method-See scope document
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 16 of 18 Parameter/Equipment Range CMC2, 6 (±) Comments Torque – Measure3 – Wrenches – Click, Dial, Adjustable, Screwdrivers 5 lbf∙in to 600 lbf∙ft 0.65 % CDI Suretest 5000- ST Rotary Torque– Measure3 – Pneumatic, DC, Pulse (0 to 180) N∙m 1.3 % Full Scale Crane-Torquestar w/ rotary transducers Pressure – Measure & Measuring Equipment3 Pneumatic Hydraulic (0 to 1) in∙H 2O (0 to 4) in∙H 2O (0.01 to 30) psig Up to 300 psig (30 to 300) psig (300 to 1000) psig (1000 to 10 000) psig Up to 100 psig (> 100 to 10 000) psig 0.002 in∙H2O 0.025 in∙H 2O 0.021 psi 0.09 psi + 0.025 % 0.21 psi 0.7 psi 7 psi 0.05 % 0.06 % Heise HM2-1 Dwyer 475 Beamex MC2-MF Beamex MC2-MF w/EXT20C Druck DPI-104 Deadweight tester Atmospheric Pressure – Measure & Measuring Equipment (Vacuum) 3 (0.01 to 28.5) in∙Hg Up to 10 Torr (10 to 100) Torr 0.02 in∙Hg 0.7 % + 0.001 Torr 0.64 % + 0.01 Torr Beamex MC2- IPM2C MKS pressure transducers Speed – Measure3 Optic/Non-contact: RPM Totalizer/Rate Meters Contact: RPM Totalizer/Rate Meters (6 to 100 000) rpm (2 to 3300) fpm (6 to 20 000) rpm (2 to 3300) fpm 0.017 % 0.017 % 0.22 % 0.22 % Monarch PLT200 Shimpo 105A
17--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 17 of 18 Parameter/Equipment Range CMC 2, 5, 6 (±) Comments Totalize Meters – Distance Measure Mechanical Counter/Totalizers3 Up to 200 ft Up to 999 999 counts 0.64 % 0.02 % + 0.6R Monarch PLT200 w/ 10cm wheel Speed/RPM– Measuring Equipment (2.5 to 100 000) RPM 0.000 24 % + 0.6R Keysight 33500B VII. Thermodynamics Parameter/Equipment Range CMC 2, 7 (±) Comments Relative Humidity – Measure3 (10 to 80) % RH 1.5 % RH Rotronic HP22A w/ HC2 Probe Temperature – Measure3 (-196 to 420) °C 0.06 °C Fluke 1524 w/5615-12 Probe Temperature – Measuring Equipment 3 (-45 to 140) °C (-15 to 350) °C 0.18 °C 0.15 °C Fluke 9170 Fluke 9009 w/ Ext Probe Infrared Thermometry – Measuring Equipment3 35 °C (35 to 100) °C (100 to 200) °C (200 to 350) °C (350 to 500) °C 0.86 °C 1 °C 1.2 °C 1.7 °C 2.3 °C Fluke 4181 Spectral band (8 to 14) µm Emissivity 0.95
to 200 ft
18--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1741.12) Revised 08/19/2024 Page 18 of 18 VIII. Time & Frequency Parameter/Equipment Range CMC2 (±) Comments Timers & Stopwatches3 (1 to 3600) s 0.2 s Monarch PLT 200 Frequency – Measure3 Up to 350 MHz 0.06 µHz/Hz Keysight 53210A Frequency – Measuring Equipment3 0.01 Hz to 2 MHz 3.1 parts in 106 + 5 µHz Fluke 5522A ______________________________________________________________ 1 This laboratory offers commercial calibration and field calibration services, where noted. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavi or of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 5 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches; R is the numerical value of the resolution of the device, DL is the diagonal length of the device in inches, and t is time in seconds. 6 In the statement of CMC, percentages are percent of reading, unless otherwise indicated. 7 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 8 This scope meets A2LA’s P112 Flexible Scope Policy. 9 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for the types of dimensional tests listed above and is considered equivalent to that of a calibration.
1 to 3600 s
19ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

354 Riverchase Way, Lexington, SC, 29072, US

33.89868, -81.27505

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.