Vertex Calibration

Office No. 1, Building 317, Street 250, Zone 43, D-Ring Road, Nuaija, Doha, Qatar, Doha, Qatar

Visit website
A2LA 7399.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
15
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 15 scope lines.

A2LA certificate 7399.01 · 15 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7399.01) 10/14/2025 Page 1 of 14 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 VERTEX CALIBRATION Office No. 1, Building 317, Street 250, Zone 43, D-Ring Road, Nuaija, Doha, QATAR Ronaldo Acosta Phone: 31299833 CALIBRATION Valid To: February 28, 2027 Certificate Number: 7399.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations1, 4: I. Acoustics Parameter/Equipment Range CMC2 (±) Comments Sound Level Meter 94 dB @ 1kHz 114 dB @ 1kHz 0.43 dB 0.43 dB Sound level calibrator Sound Level Calibrator 94 dB @ 1kHz 114 dB @ 1kHz 0.92 dB 0.92 dB Sound level meter II. Chemical Quantities Parameter/Equipment Range CMC2 (±) Comments pH – Measuring Equipment3 4.015 pH 7.003 pH 10.015 pH 0.02 pH 0.02 pH 0.02 pH Traceable buffer solutions Conductivity – Measuring Equipment3 84 µS/cm 1413 µS/cm 12 880 µS/cm 1 µS/cm 5.2 µS/cm 50 µS/cm Traceable conductivity solutions
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7399.01) 10/14/2025 Page 2 of 14 Parameter/Equipment Range CMC2 (±) Comments Turbidity – Measuring Equipment3 1.0 NTU 20 NTU 100 NTU 200 NTU 1000 NTU 4000 NTU 0.04 NTU 0.55 NTU 1.2 NTU 2.2 NTU 7.2 NTU 38 NTU Traceable turbidity solutions Gas Detector Analyzer CO H25 O2 CH4 (Methane) 100 ppm 25 ppm 18 % 2.5% (50% LEL) 2.0 % 2.0 % 2.0 % 2.0 % Certified gas concentrations Single Gas Detector O2 25% 2.0 % Certified gas concentration III. Dimensional Parameter/Equipment Range CMC2 (±) Comments Micrometers Digital & Mechanical (0 to 25) mm (25 to 50) mm (75 to 100) mm (100 to 125) mm (125 to 150) mm (150 to 175) mm (175 to 200) mm (200 to 300) mm (300 to 400) mm (400 to 500) mm (500 to 600) mm (600 to 700) mm (700 to 800) mm (800 to 900) mm (900 to 1000) mm 0.0008 mm 0.006 mm 0.006 mm 0.006 mm 0.006 mm 0.006 mm 0.006 mm 0.006 mm 0.006 mm 0.006 mm 0.006 mm 0.007 mm 0.007 mm 0.007 mm 0.007 mm Optical flats, optical parallel & gauge blocks, grade 0, 1 & Grade K
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7399.01) 10/14/2025 Page 3 of 14 Parameter/Equipment Range CMC2 (±) Comments Setting Standard for Micrometer (0 to 25) mm 3.6 µm Micrometer Caliper – Vernier, Dial, Digital, Spring type Outside Measurement Inside Measurement Depth Measurement Up to 600 mm Up to 1000 mm 0.009 mm 0.010 mm Gauge blocks K, grade 0 & 1, caliper checker Laser Distance Meter Up to 1000 mm 0.0027 m Comparison to laser distance meter & gauge blocks. Measuring Ruler/Scale Up to 100 mm (100 to 1000) mm 0.29 mm 0.58 mm Gauge block Set Dial Gauge & Indicators Up to 5 mm (5 to 10) mm (10 to 25) mm (25 to 50) mm (50 to 100) mm 0.003 mm 0.003 mm 0.003 mm 0.007 mm 0.007 mm Dial gauge calibrator, gauge block Feeler Gauge Width Gauge Up to 25 mm 0.004 mm Digital micrometer, gauge block set Thickness Gauge Up to 5 mm (5 to 10) mm (10 to 20) mm (20 to 30) mm (30 to 40) mm (40 to 50) mm (50 to 60) mm (60 to 70) mm (70 to 80) mm (80 to 90) mm (90 to 100) mm 0.001 mm 0.001 mm 0.001 mm 0.001 mm 0.006 mm 0.006 mm 0.006 mm 0.006 mm 0.006 mm 0.006 mm 0.006 mm Gauge block Standard Shims Up to 750 µm (0.75 to 1.2) mm (1.2 to 5) mm 1.4 µm 8.1 µm 2.5 µm Digital micrometer, DFT gauge
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7399.01) 10/14/2025 Page 4 of 14 Parameter/Equipment Range CMC2 (±) Comments Test Sieves (38 to 850) µm (1 to 125) mm 4.5 µm 5.4 µm Video measuring machine Fixture Gauges X-Axis Y-Axis Up to 250 mm Up to 200 mm 5.3 µm 5.1 µm Video measuring machine Video Measuring Machine3 (0 to 150 mm) 17 µm Glass scale Surface Plate (Local Area Flatness Only) Up to 1000 mm Up to 37 in 3.3 µm 130 µin Repeat-o-meter Coating Thickness Gauge 79.5 µm 258.7 µm 1486.7 µm 1.6 µm 1.8 µm 1.8 µm Foil set scale IV. Electrical -- DC/Low Frequency Parameter/Equipment Range CMC2, 6 (±) Comments DC Voltage – Generate (0.1 to 330) mV 330 mV to 3.3 V (3.3 to 33) V (33 to 330) V (330 to 1000) V 0.0083 mV 0.045 mV 0.52 mV 7.1 mV 0.02 V Multi-product calibrator DC Voltage – Measure Up to 100 mV (0.1 to 1) V (1 to 10) V (10 to 100) V 100 V to 1 kV 0.15 mV 0.000 92 V 0.0092 V 0.023 V 0.23 V 6 ½ Multimeter
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7399.01) 10/14/2025 Page 5 of 14 Parameter/Equipment Range CMC2, 6 (±) Comments DC High Voltage – Measure Up to 5 kV (5 to 10) kV (10 to 15) kV (15 to20) kV (20 to 30) kV (30 to 40) kV 0.12 kV 0.31 kV 0.53 kV 0.61 kV 0.88 kV 1.2 kV High voltage probe & meter DC Current – Generate (0.1 to 330) µA 330 µA to 3.3 mA (3.3 to 33.3) mA (33.3 to 330) mA (0.33 to 1) A (1 to 3) A (3 to 10) A (10 to 20) A (20 to 400) A (400 to 1000) A 0.90 µA 0.0006 mA 0.004 mA 0.15 mA 0.72 mA 4.6 mA 24 mA 89 mA 0.66 % of rdg 1.2 % rdg Multi-product calibrator, current coil. DC Current – Measure (1 to 100) µA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA 100 mA to 1 A (1 to 10) A 0.10 µA 0.0007 mA 0.012 mA 0.067 mA 0.0088 A 0.021 A 6 ½ Multimeter Resistance – Generate (1 to 10) Ω (10 to 100) Ω 100 Ω to 1 kΩ (1 to 10) kΩ (10 to 100) kΩ (100 to 1000) kΩ (1 to 10) MΩ (10 to 100) MΩ (100 to 1000) MΩ 0.43 mΩ 0.0034 Ω 0.03 Ω 0.31 Ω 3.4 Ω 0.036 kΩ 1.4 kΩ 0.058 MΩ 17 MΩ Multiproduct calibrator DC Resistance – Measure (0 to10) Ω (10 to 100) Ω 100 Ω to 1 kΩ (1 to 10) kΩ (10 to 100) kΩ 100 kΩ to 1 MΩ (1 to 10) MΩ (10 to 100) MΩ 100 MΩ to 1 GΩ 0.022 Ω 0.031 Ω 0.15 Ω 1.2 Ω 0.015 kΩ 0.15 kΩ 8.5 kΩ 0.12 MΩ 29 MΩ 6 ½ Multimeter
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7399.01) 10/14/2025 Page 6 of 14 Parameter/Equipment Range CMC2, 6 (±) Comments Temperature Simulation – RTD 3 (Pt–100, Pt–200, Pt–500, Pt–1000) (–200 to 600) °C 0.27 °C Multiproduct calibrator & multifunction calibrator Temperature Simulation – Thermocouples3 Type B Type C Type E Type J Type K Type L Type N Type R Type S Type T Type U (600 to 1820) °C (0 to 2316) °C (- 250 to 0) °C (0 to 1000) °C (- 210 to 1200) °C (- 200 to 800) °C (800 to 1372) °C (- 200 to 1300) °C (- 200 to 0) °C (0 to 1300) °C (0 to 1767) °C (0 to 1767) °C (- 250 to 0) °C (0 to 400) °C (- 200 to 0) °C (0 to 600) °C 0.7 °C 1.2 °C 0.59 °C 0.26 °C 0.28 °C 0.39 °C 0.47 °C 0.44 °C 0.47 °C 0.32 °C 0.66 °C 0.55 °C 0.74 °C 0.28 °C 0.65 °C 0.32 °C Multiproduct calibrator, multifunction calibrator Capacitance – Generate (0.5 to 330) nF (0.33 to 330 µF (0.33 to 110) mF 2.9 % 0.65 % 3.9 % Decade capacitance box, Capacitance – Measure (100 to 500) pF (0.5 to 500) nF (0.5 to 500) µF (0.5 to 2) mF 1.5 % 1.2 % 0.5 % 0.85 % LCR Meter
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7399.01) 10/14/2025 Page 7 of 14 Parameter/Equipment Range CMC2, 6 (±) Comments Inductance – Generate @1 kHz 100 µH to 10 H 1.2 % Decade inductance box Inductance – Measure @1 kHz 100 µH to 10 H 1.2 % LCR Meter Parameter/Equipment Frequency CMC2, 6 (±) Comments AC Current – Measure (10 to 100) µA (0.1 to 11) mA (1 to 10) mA (10 to 100) mA 100 mA to 1 A (1 to 10) A 50 Hz to 1 kHz 0.51 µA 0.0019 mA 0.038 mA 0.16 mA 0.0017 A 0.030 A 6 ½ Multimeter Electrical safety tester AC Current – Generate (30 to 330) μA 330 µA to 3.3 mA (3.3 to 33.3) mA (33.3 to 330) mA (0.33 to 1.1) A (1.1 to 3) A (3 to 11) A (11 to 20) A (20 to 100) A (100 to 400) A (400 to 1000) A 50 Hz to 1 kHz 2.1 μA 4.2 μA 0.026 mA 0.43 mA 1.1 mA 2 mA 0.018 A 0.044 A 0.92 % of rdg 0.39 % of rdg 0.38 % of rdg Multi-product calibrator Current coil
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7399.01) 10/14/2025 Page 8 of 14 Parameter/Equipment Frequency CMC2, 6 (±) Comments AC Voltage – Generate (3 to 33) mV (33 to 330) mV 330 mV to 3.3 V (3.3 to 33) V (33 to 330) V (330 to 1000) V 50 Hz to 1 kHz 0.013 mV 0.092 mV 0.000 77 V 0.0086 V 0.093 V 0.36 V Multi-product calibrator AC Voltage – Measure (10 to 500) mV 500 mV to 1 V (1to 10) V (10 to 100) V (100 to 1000) V 50 Hz to 1 kHz 0.15 mV 0.0012 V 0.012 V 0.12 V 0.63 V 6 ½ Multimeter AC High Voltage – Measure Up to 2 kV (2 to 5) kV (5 to 10) kV (10 to 15) kV (15 to 20) kV (20 to 28) kV 50 Hz 0.11 kV 0.29 kV 0.61 kV 0.96 kV 1.2 kV 1.7 kV High voltage Probe & meter V. Fluid Quantities Parameter/Equipment Range CMC2, 5 (±) Comments Air Velocity (0.2 to 30) m/s 0.08 m/s Vane probe anemometer Air Flow3 (0 to 20) L/min 0.50 L/min Air flow calibrator
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7399.01) 10/14/2025 Page 9 of 14 VI. Mechanical Parameter/Equipment Range CMC2, 5 (±) Comments Pressure – Hydraulics & Pneumatics3 (0 to 20) bar (0 to 40) bar (40 to 60) bar (60 to 70) bar (0 to 100) bar (100 to 200) bar (0 to 300) bar (300 to 400) bar (400 to 500) bar (500 to 600) bar (600 to 700) bar (700 to 800) bar (800 to 1000) bar 0.007 bar 0.06 bar 0.06 bar 0.06 bar 0.13 bar 0.13 bar 0.62 bar 0.62 bar 0.62 bar 0.62 bar 0.62 bar 1.1 bar 1.3 bar Deadweight tester, master gauge with comparator, hand held pressure calibrator Vacuum Gauge3 (0 to -1) bar 0.007 bar Pressure calibrator Force & Load Cell3 Compression Tension (0 to 200) kN (0 to 900) kN (900 to 1800) KN (1800 to 3000) KN (0 to 10) kN (10 to 50) kN (50 to 100) kN (100 to 200) kN 0.40 kN 0.09 kN 0.52 KN 0.90 KN 0.36 kN 0.36 kN 0.36 kN 0.39 kN Master load cell Scales & Balances3 Micro-Balance, Analytical, Precision & Electronic (0 to 20) g (20 to 50) g (50 to 100) g (100 to 200) g (200 to 300) g (300 to 400) g (400 to 500) g (500 to 600) g 0.05 mg 0.21 mg 0.17 mg 0.26 mg 8.8 mg 8.8 mg 13 mg 13 mg Standard test weight E1, E2, F1, M1
10-Mass (Weights/Bullion); Scales & Balances3
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7399.01) 10/14/2025 Page 10 of 14 Parameter/Equipment Range CMC2, 5 (±) Comments Scales & Balances3 (cont) Platforms, Spring, Batching (600 to 800) g (800 to 1000) g (1 to 2) kg (2 to 5) kg (5 to 10) kg (10 to 15) kg (15 to 20) kg (20 to 40) kg (40 to 60) kg (60 to 80) kg (80 to 100) kg (100 to 120) kg (120 to 140) kg (140 to 160) kg (160 to 180) kg (180 to 200) kg (200 to 220) kg (220 to 240) kg (240 to 280) kg (280 to 300) kg 13 mg 13 mg 13 mg 14 mg 17 mg 60 mg 62 mg 9.0 g 9.2 g 9.2 g 13 g 13 g 13 g 13 g 13 g 14 g 14 g 14 g 14 g 14 g Standard test weight E1, E2, F1 Standard test weight F1, M1 Mass (Weights/Bullion) (1 to 5) mg 10 mg 20 mg 50 mg 100 mg 200 mg 300 mg 400 mg 500 mg 1 g 2 g 5 g 10 g 20 g 50 g 100 g 200 g 500 g 1000 g 2000 g 5000 g 10 000 g 20 000 g 0.0016 mg 0.0016 mg 0.0016 mg 0.0021 mg 0.0025 mg 0.0031 mg 0.0031 mg 0.0031 mg 0.0041 mg 0.005 mg 0.007mg 0.010 mg 0.015 mg 0.026 mg 0.083 mg 0.13 mg 0.24 mg 5.8 mg 7.7 mg 8.1 mg 8.3 mg 14 mg 210 mg Micro-balance, analytical balance precision balance, electronic balance, platform scale
See scope document
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7399.01) 10/14/2025 Page 11 of 14 Parameter/Equipment Range CMC2, 5 (±) Comments Torque Testers/Tools (0 to 400) N·m (400 to 1500) N·m 0.44 % 0.29 % Torque tester, torque transducer, torque display Volume Pipettes, Micropipettes, & Burettes Volumetric Flasks, Dispensers, & Measuring Cylinders (0 to 10) µL (10 to 20) µL (20 to 50) µL (50 to 100) µL (100 to 200) µL (200 to 500) µL (500 to 1000) µL (1 to 5) mL (5 to 10) mL (10 to 20) mL (20 to 50) mL (50 to 100) mL (100 to 200) mL (200 to 500) mL (500 to 1000) mL (1000 to 2000) mL 0.16 µL 0.16 µL 0.16 µL 0.16 µL 0.16 µL 0.99 µL 1.6 µL 0.008 ml 0.007 ml 0.007 ml 0.05 ml 0.05 ml 0.10 ml 0.10 ml 0.10 ml 0.10 ml Micro-balance, analytical balance, electronic balance & standard weights VII. Optical Parameter/Equipment Range CMC2 (±) Comments OTDR Distance Loss Centroidal Wavelength Single mode Multimode (Single/multi mode) 1km (Single/multi mode) 2km (1310/1550 nm) 1 km (1310/1550 nm) 2 km (850 ~ 1650) nm 1.4 m 2.5 m 0.02 dB 0.02 dB 1.2 nm Power meter Spectrum analyzer
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7399.01) 10/14/2025 Page 12 of 14 Parameter/Equipment Range CMC2 (±) Comments Power Meter Power Accuracy Linearity/Non- Linearity (1310 nm) 10 µW (1550 nm) 10 µW (1550 nm) 0 ~ -50dB 0.1 µW 0.1 µW 0.01 dB Power meter Laser source Attenuator Laser Source Output Power CW Stability Wavelength (-50 to 3) dBm 0 dBm 1310 nm/1550 nm 0.02 dB 0.007 dB 0.06 nm Power meter Lightwave multimeter Spectrum Analyzer Absolute Wavelength Resolution Bandwidth Linearity/Non- Linearity (1310/1550) nm (0.5 ~ 10) nm (1310/1550) nm (1550 nm) 0 ~ -50dB 0.06 nm 0.007 nm 0.01 dB Laser source Power meter Laser source attenuator VIII. Thermodynamics Parameter/Equipment Range CMC2, 5 (±) Comments Hygrometer (10 to 95) % RH (5 to 60) ˚C 1.1 % RH 0.44 ˚C Humidity chamber, reference meter Temperature Chambers, Ovens, Incubators, Furnaces, Chillers, Freezers, Fridges3 (-100 to 0) ˚C (0 to 50) ˚C (50 to 200) ˚C (200 to 400) ˚C (400 to 700) ˚C (700 to 1200) ˚C 0.22 ˚C 0.21 ˚C 0.27 ˚C 0.38 ˚C 0.56 ˚C 1.7 ˚C Datalogger, multifunction calibrator, SPRT, 6½ DMM, reference thermometer
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7399.01) 10/14/2025 Page 13 of 14 Parameter/Equipment Range CMC2, 5 (±) Comments Temperature3 – Measuring Equipment, Transmitters, Temperature Bath, Liquid in Glass Thermometers, Thermocouple Sensors, RTD Temperature Mapping incubator, chiller, freezer, furnace, oven, fridges, (9 Points)3 (-35 to 0) ˚C (0 to 25) ˚C (25 to 50) ˚C (50 to 100) ˚C (100 to 150) ˚C (150 to 200) ˚C (200 to 300) ˚C (300 to 400) ˚C (400 to 500) ˚C (500 to 650) ˚C (0 to 1000) ˚C (-25 to 1200) ˚C 0.22 ˚C 0.22 ˚C 0.22 ˚C 0.27 ˚C 0.27 ˚C 0.27 ˚C 0.27 ˚C 0.27 ˚C 0.27 ˚C 0.27 ˚C 0.6 ˚C Dry block calibrator, oil bath, reference thermometer Multichannel data logger with RTD/TC sensor Infrared Thermometer & Pyrometer Up to 500 ˚C 4.1 ˚C Black body calibrator IX. Time & Frequency Parameter/Equipment Range CMC2, 5 (±) Comments Frequency – Measure 1 Hz to 1 MHz 1 MHz to 225 MH 0.02 % 0.000 03 % 6½ Multimeter Frequency counter Frequency – Generate 5 Hz to 10 kHz 10 kHz to 1 MHz 0.07 % 0.59 % 6½ Multimeter Frequency counter Timers, Stopwatches, Chronometers3 Timers, Stopwatches, Chronometers Up to 1200 s (1200 to 3600) s Up to 1200 s (1200 to 3600) s 0.016 s 0.58 s 0.03 s 0.06 s Stopwatch Frequency counter
14--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 7399.01) 10/14/2025 Page 14 of 14 Parameter/Equipment Range CMC2, 5 (±) Comments Photo-Tachometer Up to 1000 rpm (1000 to 2000) rpm (2000 to 10 000) rpm (10 000 to 99 999) rpm 0.1 rpm 0.41 rpm 1.3 rpm 2.9 rpm Function generator, LED system Rotational Speed3 - Centrifuge Up to 1000 rpm (1000 to 10 000) rpm (10 000 to 50 000) rpm (50 000 to 90 000) rpm 3 rpm 13 rpm 65 rpm 120 rpm Reference noncontact tachometer __________________________________________________ 1 This laboratory offers commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95% level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 This scope meets A2LA’s P112 Flexible Scope Policy. 5 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 6 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or as a fraction/percentage of the reading plus a fixed floor specification.
to 99999 rpm
15

Extracted from the scope document; tables may not line up. View scope for the original.

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited VERTEX CALIBRATION Doha, QATAR for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:20 17 General requirements for the competence of testing and calibration laboratories . This laboratory also meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 14th day of February 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 7399.01 Valid to February 28, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Office No. 1, Building 317, Street 250, Zone 43, D-Ring Road, Nuaija, Doha, Qatar, Doha, QA

25.31088, 51.50818

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.