Vertex Calibration
Office No. 1, Building 317, Street 250, Zone 43, D-Ring Road, Nuaija, Doha, Qatar, Doha, Qatar
Visit website- Scope lines
- 15
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We found no published test standard numbers in this lab’s scope. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 15 scope lines.
A2LA certificate 7399.01 · 15 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7399.01) 10/14/2025 Page 1 of 14
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
VERTEX CALIBRATION
Office No. 1, Building 317, Street 250, Zone 43, D-Ring Road, Nuaija,
Doha, QATAR
Ronaldo Acosta Phone: 31299833
CALIBRATION
Valid To: February 28, 2027 Certificate Number: 7399.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is
granted to this laboratory to perform the following calibrations1, 4:
I. Acoustics
Parameter/Equipment
Range
CMC2 (±)
Comments
Sound Level Meter
94 dB @ 1kHz
114 dB @ 1kHz
0.43 dB
0.43 dB
Sound level calibrator
Sound Level Calibrator
94 dB @ 1kHz
114 dB @ 1kHz
0.92 dB
0.92 dB
Sound level meter
II. Chemical Quantities
Parameter/Equipment
Range
CMC2 (±)
Comments
pH – Measuring
Equipment3
4.015 pH
7.003 pH
10.015 pH
0.02 pH
0.02 pH
0.02 pH
Traceable buffer solutions
Conductivity – Measuring
Equipment3
84 µS/cm
1413 µS/cm
12 880 µS/cm
1 µS/cm
5.2 µS/cm
50 µS/cm
Traceable conductivity
solutions | ||
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7399.01) 10/14/2025 Page 2 of 14
Parameter/Equipment
Range
CMC2 (±)
Comments
Turbidity – Measuring
Equipment3
1.0 NTU
20 NTU
100 NTU
200 NTU
1000 NTU
4000 NTU
0.04 NTU
0.55 NTU
1.2 NTU
2.2 NTU
7.2 NTU
38 NTU
Traceable turbidity solutions
Gas Detector Analyzer
CO
H25
O2
CH4 (Methane)
100 ppm
25 ppm
18 %
2.5% (50% LEL)
2.0 %
2.0 %
2.0 %
2.0 %
Certified gas concentrations
Single Gas Detector
O2
25%
2.0 %
Certified gas concentration
III. Dimensional
Parameter/Equipment
Range
CMC2 (±)
Comments
Micrometers
Digital & Mechanical
(0 to 25) mm
(25 to 50) mm
(75 to 100) mm
(100 to 125) mm
(125 to 150) mm
(150 to 175) mm
(175 to 200) mm
(200 to 300) mm
(300 to 400) mm
(400 to 500) mm
(500 to 600) mm
(600 to 700) mm
(700 to 800) mm
(800 to 900) mm
(900 to 1000) mm
0.0008 mm
0.006 mm
0.006 mm
0.006 mm
0.006 mm
0.006 mm
0.006 mm
0.006 mm
0.006 mm
0.006 mm
0.006 mm
0.007 mm
0.007 mm
0.007 mm
0.007 mm
Optical flats, optical parallel
& gauge blocks, grade 0, 1
& Grade K | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7399.01) 10/14/2025 Page 3 of 14
Parameter/Equipment
Range
CMC2 (±)
Comments
Setting Standard for
Micrometer
(0 to 25) mm
3.6 µm
Micrometer
Caliper –
Vernier, Dial, Digital,
Spring type
Outside Measurement
Inside Measurement
Depth Measurement
Up to 600 mm
Up to 1000 mm
0.009 mm
0.010 mm
Gauge blocks K, grade 0
& 1, caliper checker
Laser Distance Meter
Up to 1000 mm
0.0027 m
Comparison to laser distance
meter & gauge blocks.
Measuring Ruler/Scale
Up to 100 mm
(100 to 1000) mm
0.29 mm
0.58 mm
Gauge block Set
Dial Gauge & Indicators
Up to 5 mm
(5 to 10) mm
(10 to 25) mm
(25 to 50) mm
(50 to 100) mm
0.003 mm
0.003 mm
0.003 mm
0.007 mm
0.007 mm
Dial gauge calibrator, gauge
block
Feeler Gauge Width
Gauge
Up to 25 mm
0.004 mm
Digital micrometer, gauge
block set
Thickness Gauge
Up to 5 mm
(5 to 10) mm
(10 to 20) mm
(20 to 30) mm
(30 to 40) mm
(40 to 50) mm
(50 to 60) mm
(60 to 70) mm
(70 to 80) mm
(80 to 90) mm
(90 to 100) mm
0.001 mm
0.001 mm
0.001 mm
0.001 mm
0.006 mm
0.006 mm
0.006 mm
0.006 mm
0.006 mm
0.006 mm
0.006 mm
Gauge block
Standard Shims
Up to 750 µm
(0.75 to 1.2) mm
(1.2 to 5) mm
1.4 µm
8.1 µm
2.5 µm
Digital micrometer, DFT
gauge | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7399.01) 10/14/2025 Page 4 of 14
Parameter/Equipment
Range
CMC2 (±)
Comments
Test Sieves
(38 to 850) µm
(1 to 125) mm
4.5 µm
5.4 µm
Video measuring machine
Fixture Gauges
X-Axis
Y-Axis
Up to 250 mm
Up to 200 mm
5.3 µm
5.1 µm
Video measuring machine
Video Measuring Machine3
(0 to 150 mm)
17 µm
Glass scale
Surface Plate
(Local Area Flatness Only)
Up to 1000 mm
Up to 37 in
3.3 µm
130 µin
Repeat-o-meter
Coating Thickness Gauge
79.5 µm
258.7 µm
1486.7 µm
1.6 µm
1.8 µm
1.8 µm
Foil set scale
IV. Electrical -- DC/Low Frequency
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
DC Voltage – Generate
(0.1 to 330) mV
330 mV to 3.3 V
(3.3 to 33) V
(33 to 330) V
(330 to 1000) V
0.0083 mV
0.045 mV
0.52 mV
7.1 mV
0.02 V
Multi-product calibrator
DC Voltage – Measure
Up to 100 mV
(0.1 to 1) V
(1 to 10) V
(10 to 100) V
100 V to 1 kV
0.15 mV
0.000 92 V
0.0092 V
0.023 V
0.23 V
6 ½ Multimeter | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7399.01) 10/14/2025 Page 5 of 14
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
DC High Voltage –
Measure
Up to 5 kV
(5 to 10) kV
(10 to 15) kV
(15 to20) kV
(20 to 30) kV
(30 to 40) kV
0.12 kV
0.31 kV
0.53 kV
0.61 kV
0.88 kV
1.2 kV
High voltage probe &
meter
DC Current – Generate
(0.1 to 330) µA
330 µA to 3.3 mA
(3.3 to 33.3) mA
(33.3 to 330) mA
(0.33 to 1) A
(1 to 3) A
(3 to 10) A
(10 to 20) A
(20 to 400) A
(400 to 1000) A
0.90 µA
0.0006 mA
0.004 mA
0.15 mA
0.72 mA
4.6 mA
24 mA
89 mA
0.66 % of rdg
1.2 % rdg
Multi-product calibrator,
current coil.
DC Current – Measure
(1 to 100) µA
(0.1 to 1) mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
(1 to 10) A
0.10 µA
0.0007 mA
0.012 mA
0.067 mA
0.0088 A
0.021 A
6 ½ Multimeter
Resistance – Generate
(1 to 10) Ω
(10 to 100) Ω
100 Ω to 1 kΩ
(1 to 10) kΩ
(10 to 100) kΩ
(100 to 1000) kΩ
(1 to 10) MΩ
(10 to 100) MΩ
(100 to 1000) MΩ
0.43 mΩ
0.0034 Ω
0.03 Ω
0.31 Ω
3.4 Ω
0.036 kΩ
1.4 kΩ
0.058 MΩ
17 MΩ
Multiproduct calibrator
DC Resistance – Measure
(0 to10) Ω
(10 to 100) Ω
100 Ω to 1 kΩ
(1 to 10) kΩ
(10 to 100) kΩ
100 kΩ to 1 MΩ
(1 to 10) MΩ
(10 to 100) MΩ
100 MΩ to 1 GΩ
0.022 Ω
0.031 Ω
0.15 Ω
1.2 Ω
0.015 kΩ
0.15 kΩ
8.5 kΩ
0.12 MΩ
29 MΩ
6 ½ Multimeter | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7399.01) 10/14/2025 Page 6 of 14
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Temperature Simulation –
RTD 3
(Pt–100, Pt–200,
Pt–500, Pt–1000)
(–200 to 600) °C
0.27 °C
Multiproduct calibrator
& multifunction calibrator
Temperature Simulation –
Thermocouples3
Type B
Type C
Type E
Type J
Type K
Type L
Type N
Type R
Type S
Type T
Type U
(600 to 1820) °C
(0 to 2316) °C
(- 250 to 0) °C
(0 to 1000) °C
(- 210 to 1200) °C
(- 200 to 800) °C
(800 to 1372) °C
(- 200 to 1300) °C
(- 200 to 0) °C
(0 to 1300) °C
(0 to 1767) °C
(0 to 1767) °C
(- 250 to 0) °C
(0 to 400) °C
(- 200 to 0) °C
(0 to 600) °C
0.7 °C
1.2 °C
0.59 °C
0.26 °C
0.28 °C
0.39 °C
0.47 °C
0.44 °C
0.47 °C
0.32 °C
0.66 °C
0.55 °C
0.74 °C
0.28 °C
0.65 °C
0.32 °C
Multiproduct calibrator,
multifunction calibrator
Capacitance – Generate
(0.5 to 330) nF
(0.33 to 330 µF
(0.33 to 110) mF
2.9 %
0.65 %
3.9 %
Decade capacitance box,
Capacitance – Measure
(100 to 500) pF
(0.5 to 500) nF
(0.5 to 500) µF
(0.5 to 2) mF
1.5 %
1.2 %
0.5 %
0.85 %
LCR Meter | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7399.01) 10/14/2025 Page 7 of 14
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Inductance – Generate
@1 kHz
100 µH to 10 H
1.2 %
Decade inductance box
Inductance – Measure
@1 kHz
100 µH to 10 H
1.2 %
LCR Meter
Parameter/Equipment
Frequency
CMC2, 6 (±)
Comments
AC Current – Measure
(10 to 100) µA
(0.1 to 11) mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
(1 to 10) A
50 Hz to 1 kHz
0.51 µA
0.0019 mA
0.038 mA
0.16 mA
0.0017 A
0.030 A
6 ½ Multimeter
Electrical safety tester
AC Current – Generate
(30 to 330) μA
330 µA to 3.3 mA
(3.3 to 33.3) mA
(33.3 to 330) mA
(0.33 to 1.1) A
(1.1 to 3) A
(3 to 11) A
(11 to 20) A
(20 to 100) A
(100 to 400) A
(400 to 1000) A
50 Hz to 1 kHz
2.1 μA
4.2 μA
0.026 mA
0.43 mA
1.1 mA
2 mA
0.018 A
0.044 A
0.92 % of rdg
0.39 % of rdg
0.38 % of rdg
Multi-product calibrator
Current coil | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7399.01) 10/14/2025 Page 8 of 14
Parameter/Equipment
Frequency
CMC2, 6 (±)
Comments
AC Voltage – Generate
(3 to 33) mV
(33 to 330) mV
330 mV to 3.3 V
(3.3 to 33) V
(33 to 330) V
(330 to 1000) V
50 Hz to 1 kHz
0.013 mV
0.092 mV
0.000 77 V
0.0086 V
0.093 V
0.36 V
Multi-product calibrator
AC Voltage – Measure
(10 to 500) mV
500 mV to 1 V
(1to 10) V
(10 to 100) V
(100 to 1000) V
50 Hz to 1 kHz
0.15 mV
0.0012 V
0.012 V
0.12 V
0.63 V
6 ½ Multimeter
AC High Voltage –
Measure
Up to 2 kV
(2 to 5) kV
(5 to 10) kV
(10 to 15) kV
(15 to 20) kV
(20 to 28) kV
50 Hz
0.11 kV
0.29 kV
0.61 kV
0.96 kV
1.2 kV
1.7 kV
High voltage Probe & meter
V. Fluid Quantities
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Air Velocity
(0.2 to 30) m/s
0.08 m/s
Vane probe anemometer
Air Flow3
(0 to 20) L/min
0.50 L/min
Air flow calibrator | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7399.01) 10/14/2025 Page 9 of 14
VI. Mechanical
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Pressure – Hydraulics &
Pneumatics3
(0 to 20) bar
(0 to 40) bar
(40 to 60) bar
(60 to 70) bar
(0 to 100) bar
(100 to 200) bar
(0 to 300) bar
(300 to 400) bar
(400 to 500) bar
(500 to 600) bar
(600 to 700) bar
(700 to 800) bar
(800 to 1000) bar
0.007 bar
0.06 bar
0.06 bar
0.06 bar
0.13 bar
0.13 bar
0.62 bar
0.62 bar
0.62 bar
0.62 bar
0.62 bar
1.1 bar
1.3 bar
Deadweight tester, master
gauge with comparator, hand
held pressure calibrator
Vacuum Gauge3
(0 to -1) bar
0.007 bar
Pressure calibrator
Force & Load Cell3
Compression
Tension
(0 to 200) kN
(0 to 900) kN
(900 to 1800) KN
(1800 to 3000) KN
(0 to 10) kN
(10 to 50) kN
(50 to 100) kN
(100 to 200) kN
0.40 kN
0.09 kN
0.52 KN
0.90 KN
0.36 kN
0.36 kN
0.36 kN
0.39 kN
Master load cell
Scales & Balances3
Micro-Balance,
Analytical, Precision
& Electronic
(0 to 20) g
(20 to 50) g
(50 to 100) g
(100 to 200) g
(200 to 300) g
(300 to 400) g
(400 to 500) g
(500 to 600) g
0.05 mg
0.21 mg
0.17 mg
0.26 mg
8.8 mg
8.8 mg
13 mg
13 mg
Standard test weight E1, E2,
F1, M1 | ||
| 10 | - | Mass (Weights/Bullion); Scales & Balances3Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7399.01) 10/14/2025 Page 10 of 14
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Scales & Balances3 (cont)
Platforms, Spring,
Batching
(600 to 800) g
(800 to 1000) g
(1 to 2) kg
(2 to 5) kg
(5 to 10) kg
(10 to 15) kg
(15 to 20) kg
(20 to 40) kg
(40 to 60) kg
(60 to 80) kg
(80 to 100) kg
(100 to 120) kg
(120 to 140) kg
(140 to 160) kg
(160 to 180) kg
(180 to 200) kg
(200 to 220) kg
(220 to 240) kg
(240 to 280) kg
(280 to 300) kg
13 mg
13 mg
13 mg
14 mg
17 mg
60 mg
62 mg
9.0 g
9.2 g
9.2 g
13 g
13 g
13 g
13 g
13 g
14 g
14 g
14 g
14 g
14 g
Standard test weight E1,
E2, F1
Standard test weight F1,
M1
Mass (Weights/Bullion)
(1 to 5) mg
10 mg
20 mg
50 mg
100 mg
200 mg
300 mg
400 mg
500 mg
1 g
2 g
5 g
10 g
20 g
50 g
100 g
200 g
500 g
1000 g
2000 g
5000 g
10 000 g
20 000 g
0.0016 mg
0.0016 mg
0.0016 mg
0.0021 mg
0.0025 mg
0.0031 mg
0.0031 mg
0.0031 mg
0.0041 mg
0.005 mg
0.007mg
0.010 mg
0.015 mg
0.026 mg
0.083 mg
0.13 mg
0.24 mg
5.8 mg
7.7 mg
8.1 mg
8.3 mg
14 mg
210 mg
Micro-balance, analytical
balance precision balance,
electronic balance,
platform scale | See scope document |
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7399.01) 10/14/2025 Page 11 of 14
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Torque Testers/Tools
(0 to 400) N·m
(400 to 1500) N·m
0.44 %
0.29 %
Torque tester, torque
transducer, torque display
Volume
Pipettes,
Micropipettes, &
Burettes
Volumetric Flasks,
Dispensers, &
Measuring Cylinders
(0 to 10) µL
(10 to 20) µL
(20 to 50) µL
(50 to 100) µL
(100 to 200) µL
(200 to 500) µL
(500 to 1000) µL
(1 to 5) mL
(5 to 10) mL
(10 to 20) mL
(20 to 50) mL
(50 to 100) mL
(100 to 200) mL
(200 to 500) mL
(500 to 1000) mL
(1000 to 2000) mL
0.16 µL
0.16 µL
0.16 µL
0.16 µL
0.16 µL
0.99 µL
1.6 µL
0.008 ml
0.007 ml
0.007 ml
0.05 ml
0.05 ml
0.10 ml
0.10 ml
0.10 ml
0.10 ml
Micro-balance, analytical
balance, electronic balance
& standard weights
VII. Optical
Parameter/Equipment
Range
CMC2 (±)
Comments
OTDR
Distance
Loss
Centroidal Wavelength
Single mode
Multimode
(Single/multi mode) 1km
(Single/multi mode) 2km
(1310/1550 nm) 1 km
(1310/1550 nm) 2 km
(850 ~ 1650) nm
1.4 m
2.5 m
0.02 dB
0.02 dB
1.2 nm
Power meter
Spectrum analyzer | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7399.01) 10/14/2025 Page 12 of 14
Parameter/Equipment
Range
CMC2 (±)
Comments
Power Meter
Power Accuracy
Linearity/Non-
Linearity
(1310 nm) 10 µW
(1550 nm) 10 µW
(1550 nm) 0 ~ -50dB
0.1 µW
0.1 µW
0.01 dB
Power meter
Laser source
Attenuator
Laser Source
Output Power
CW Stability
Wavelength
(-50 to 3) dBm
0 dBm
1310 nm/1550 nm
0.02 dB
0.007 dB
0.06 nm
Power meter
Lightwave multimeter
Spectrum Analyzer
Absolute Wavelength
Resolution Bandwidth
Linearity/Non-
Linearity
(1310/1550) nm
(0.5 ~ 10) nm
(1310/1550) nm
(1550 nm)
0 ~ -50dB
0.06 nm
0.007 nm
0.01 dB
Laser source
Power meter
Laser source
attenuator
VIII. Thermodynamics
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Hygrometer
(10 to 95) % RH
(5 to 60) ˚C
1.1 % RH
0.44 ˚C
Humidity chamber, reference
meter
Temperature Chambers,
Ovens, Incubators,
Furnaces, Chillers,
Freezers, Fridges3
(-100 to 0) ˚C
(0 to 50) ˚C
(50 to 200) ˚C
(200 to 400) ˚C
(400 to 700) ˚C
(700 to 1200) ˚C
0.22 ˚C
0.21 ˚C
0.27 ˚C
0.38 ˚C
0.56 ˚C
1.7 ˚C
Datalogger, multifunction
calibrator, SPRT, 6½ DMM,
reference thermometer | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7399.01) 10/14/2025 Page 13 of 14
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Temperature3 – Measuring
Equipment, Transmitters,
Temperature Bath, Liquid
in Glass Thermometers,
Thermocouple Sensors,
RTD
Temperature Mapping
incubator, chiller,
freezer, furnace, oven,
fridges, (9 Points)3
(-35 to 0) ˚C
(0 to 25) ˚C
(25 to 50) ˚C
(50 to 100) ˚C
(100 to 150) ˚C
(150 to 200) ˚C
(200 to 300) ˚C
(300 to 400) ˚C
(400 to 500) ˚C
(500 to 650) ˚C
(0 to 1000) ˚C
(-25 to 1200) ˚C
0.22 ˚C
0.22 ˚C
0.22 ˚C
0.27 ˚C
0.27 ˚C
0.27 ˚C
0.27 ˚C
0.27 ˚C
0.27 ˚C
0.27 ˚C
0.6 ˚C
Dry block calibrator, oil bath,
reference thermometer
Multichannel data logger with
RTD/TC sensor
Infrared Thermometer &
Pyrometer
Up to 500 ˚C
4.1 ˚C
Black body calibrator
IX. Time & Frequency
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Frequency – Measure
1 Hz to 1 MHz
1 MHz to 225 MH
0.02 %
0.000 03 %
6½ Multimeter
Frequency counter
Frequency – Generate
5 Hz to 10 kHz
10 kHz to 1 MHz
0.07 %
0.59 %
6½ Multimeter
Frequency counter
Timers, Stopwatches,
Chronometers3
Timers, Stopwatches,
Chronometers
Up to 1200 s
(1200 to 3600) s
Up to 1200 s
(1200 to 3600) s
0.016 s
0.58 s
0.03 s
0.06 s
Stopwatch
Frequency counter | ||
| 14 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 7399.01) 10/14/2025 Page 14 of 14
Parameter/Equipment
Range
CMC2, 5 (±)
Comments
Photo-Tachometer
Up to 1000 rpm
(1000 to 2000) rpm
(2000 to 10 000) rpm
(10 000 to 99 999) rpm
0.1 rpm
0.41 rpm
1.3 rpm
2.9 rpm
Function generator, LED
system
Rotational Speed3 -
Centrifuge
Up to 1000 rpm
(1000 to 10 000) rpm
(10 000 to 50 000) rpm
(50 000 to 90 000) rpm
3 rpm
13 rpm
65 rpm
120 rpm
Reference noncontact
tachometer
__________________________________________________
1 This laboratory offers commercial calibration service.
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95% level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects su ch as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g., resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 This scope meets A2LA’s P112 Flexible Scope Policy.
5 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
6 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured
value in the ranges indicated. CMCs are expressed as either a specific value that covers the full range or
as a fraction/percentage of the reading plus a fixed floor specification. | to 99999 rpm |
| 15 | Extracted from the scope document; tables may not line up. View scope for the original. For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
VERTEX CALIBRATION
Doha, QATAR
for technical competence in the field of
Calibration
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:20 17
General requirements for the competence of testing and calibration laboratories . This laboratory also meets R205 – Specific
Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a
defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 14th day of February 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 7399.01
Valid to February 28, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Office No. 1, Building 317, Street 250, Zone 43, D-Ring Road, Nuaija, Doha, Qatar, Doha, QA
25.31088, 51.50818
Open in MapsAccreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.