What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 98 standard numbers and the 31 official names we hold. When no standard matches, it searches the method text of every scope line.
ETSI34
ETSI EN 300 086
ETSI EN 300 113
ETSI EN 300 219-1
ETSI EN 300 220-1
ETSI EN 300 220-2
ETSI EN 300 220-3-1
ETSI EN 300 220-3-2
ETSI EN 300 220-4
ETSI EN 300 296
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 330Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 300 386
Show all 34
ETSI EN 300 440
ETSI EN 301 441Some clauses
Limits written next to it
EN 301 441 (limited to Radio Emissions)
ETSI EN 301 489-1
ETSI EN 301 489-12
ETSI EN 301 511Global System for Mobile communications (GSM); Mobile Stations (MS) equipment; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 301 893
ETSI EN 301 908-1
ETSI EN 301 908-2
ETSI EN 301 908-13
ETSI EN 302 065-1
ETSI EN 302 065-2
ETSI EN 302 065-3
ETSI EN 302 065-4
ETSI EN 302 208
ETSI EN 302 502
ETSI EN 302 561Range limit
Limits written next to it
EN 302 561(limited to RX and Tx)
ETSI EN 303 413Satellite Earth Stations and Systems (SES); Global Navigation Satellite System (GNSS) receivers; Radio equipment operating in the 1 164 MHz to 1 300 MHz and 1 559 MHz to 1 610 MHz frequency bands; Harmonised Standard for access to radio spectrum
ETSI EN 303 417
ETSI EN 303 687Range limit
Limits written next to it
EN 303 687 (limited to RX and Tx)
ETSI EN 303 758Range limit
Limits written next to it
EN 303 758(limited to RX and Tx)
ETSI EN 303 883
ETSI TS 103 701
IEC 60335 series22
IEC 60335-1Household and similar electrical appliances - Safety - Part 1: General requirements
IEC 60335-2-6
IEC 60335-2-7
IEC 60335-2-11
IEC 60335-2-12Household and similar electrical appliances - Safety - Part 2-12: Particular requirements for warming plates and similar appliances
IEC 60335-2-21
IEC 60335-2-24
IEC 60335-2-29
IEC 60335-2-30
IEC 60335-2-37
IEC 60335-2-38
IEC 60335-2-52
Show all 22
IEC 60335-2-55
IEC 60335-2-60
IEC 60335-2-64
IEC 60335-2-65
IEC 60335-2-75
IEC 60335-2-80
IEC 60335-2-82
IEC 60335-2-85
IEC 60335-2-89+1 national
National versions in the same scope
AS/NZS 60335-2-89probably the same standard; matched by number only
IEC 60335-2-90+1 national
National versions in the same scope
AS/NZS 60335-2-90probably the same standard; matched by number only
IEC13
IEC 60068-2-6Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60204-1Safety of machinery - Electrical equipment of machines - Part 1: General requirements
IEC 60255-21-1
IEC 60255-21-2
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests+1 national
National versions in the same scope
KS C IEC 60601-1-2probably the same standard; matched by number only
IEC 60601-1-11Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment
IEC 60950-1Information technology equipment - Safety - Part 1: General requirements
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61326-2-6Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical electrical equipment
IEC 62133-1
IEC 62133-2Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications - Part 2: Lithium systems
IEC 62301
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements
IEC 61010 series7
IEC 61010-1Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
IEC 61010-2-010
IEC 61010-2-051
IEC 61010-2-081
IEC 61010-2-091
IEC 61010-2-101Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-101: Particular requirements for in vitro diagnostic (IVD) medical equipment
IEC 61010-2-201
CISPR6
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+2 national
National versions in the same scope
AS CISPR 11national version with changes
KS C 9811national version with changes
CISPR 13Sound and television broadcast receivers and associated equipment - Radio disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS/NZS CISPR 13identical to it
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+3 national
National versions in the same scope
AS/NZS CISPR 14.1national version with changes
CNS 13783-1identical to it
KS C 9814-1national version with changes
CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment+2 national
National versions in the same scope
AS/NZS CISPR 15national version with changes
KS C 9815national version with changes
CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS/NZS CISPR 22identical to it
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+4 national
National versions in the same scope
AS/NZS CISPR 32identical to it
CNS 15936identical to it
KS C 9832national version with changes
VCCI-CISPR 32probably the same standard; matched by number only
IEC 60598 series5
IEC 60598-1Luminaires - Part 1: General requirements and tests
IEC 60598-2-1
IEC 60598-2-2
IEC 60598-2-4
IEC 60598-2-5
IEC 61000 series4
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)+1 national
National versions in the same scope
AS/NZS 61000.3.2identical to it
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection+1 national
National versions in the same scope
AS/NZS 61000.3.3identical to it
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments+2 national
National versions in the same scope
AS/NZS 61000.6.3national version with changes
KS C 9610-6-3national version with changes
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments+2 national
National versions in the same scope
AS/NZS 61000.6.4identical to it
KS C 9610-6-4national version with changes
Other standards7
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ANSI C63.26
EN 50121-4Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus
FCC PART 15Radio Frequency Devices
J55014-1
MIL-STD-810
RSS-GEN
RSS-GEN; RSS-102 Issue 6; RSS-102.IPD.MEAS; RSS-210 (<40 GHz); RSS-211 (<40 GHz); RSS-213; RSS-216 (<40 GHz); RSS-220 (<40 GHz); RSS-222; RSS-236; RSS-243; RSS-244; RSS-246; RSS-247 (with DFS); RSS-248; RSS-252; RSS-287; RSS-288; RSS-310; EN 300 086; EN 300 113; EN 300 220-1; EN 300 220-2; EN 300 220-3-1; EN 300 220-3-2; EN 300 220-4; EN 300 296; EN 300 328; EN 300 330; EN 300 386; EN 300 440; EN 301 489-1; EN 301 489-12; EN 301 893; EN 302 065-1; EN 302 065-2; EN 302 065-3; EN 302 065-4; EN 303 883; EN 302 502; EN 302 208; EN 303 413; EN 303 417; EN 301 441 (limited to Radio Emissions); EN 301 511; EN 301 908-1; EN 301 908-2; EN 301 908-13; EN 303 687 (limited to RX and Tx); EN 303 758(limited to RX and Tx); EN 300 219 (limited to RX and Tx); EN 302 561(limited to RX and Tx); 47 CFR, FCC Part 22 (cellular), Part 24, Part 25 (below 3 GHz), Part 27 (using ANSI C63.26-2015); ANSI C63.26-2015; ANSI/TIA-603-E 2016; 47 CFR, Part 22 (non-cellular), Part 90 (below 3 GHz), Part 95 (below 3 GHz), Part 97 (below 3 GHz), Part 101 (below 3 GHz), (using ANSI C63.26-2015); 47 CFR, Part 96 (using ANSI C63.26-2015); 47 CFR, Part 73, Part 74 (below 3 GHz), (using ANSI C63.26-2015); 47 CFR, Part 20, Part 90.219 (using ANSI C63.26-2015); 47 CFR, FCC Part 80, Part 87 (using ANSI C63.26-2015); 47 CFR, FCC Part 25, Part 30, Part 74, Part 90 (above 3 GHz), Part 95 (above 3 GHz), Part 97 (above 3 GHz), Part 101 (using ANSI C63.26-2015); RSS-GEN; RSS-102 Issue 6; RSS-102.IPD.MEAS; RSS-111; RSS-112; RSS-119; RSS-123; RSS-125; RSS-127; RSS-130; RSS-131; RSS-132; RSS-133; RSS-134; RSS-135; RSS-137; RSS-139; RSS-140
IEC 60335-2-85: 1997; EN 60335-2-85:2003/A2:2020; IEC/EN 60335-2-85; IEC 60335-2-89:2019; IEC 60335-2-89:2010/A2:2015; EN 60335-2-89:2010/A2:2017; EN IEC 60335-2-89:2022/A11:2022; CSA 60335-2-89:21; AS/NZS 60335-2-89:2020; IEC/EN/CSA/AS-NZS 60335-2-89; IEC 60335-2-90:2015/A1:2019; IEC 60335-2-90:2006/A2:2014; EN 60335-2-90:2006/A1:2010; EN IEC 60335-2-90:2021; AS/NZS 60335-2-90:2020; IEC/EN/CSA/AS-NZS 60335-2-90; UL 1561; UL 507:2017/R:2023-08; CSA C22.2 No.113:2018; UL 197; CSA C22.2 No. 187; UL 867; CSA C22.2 No. 107.1; CSA C22.2 No. 107.2; CSA C22.2 No. 107.3; UL 22; UL 1563; UL 174; IEC/UL/CSA 60730-2-x (All Inclusive); UL 50/50E CSA 94.x (All Inclusive); IEC/EN 60204-1; UL 3030; UL 3100; UL 9741; UL 73; TS 103 701
CSA C22.2 No. 61010-091; UL 61010-2-091; EN 61010-2-091; UL 61010-2-020; UL/CSA/EN/IEC/AS/NZS 60950-1; EN 60950-1 (Ed.2)+A1+A2; EN 60950-1 (2006+A11:2009+A1:2010+A12:2011+A2:2013); IEC 60950-1 (2001, 2005+A1:2009+A2:2013); IEC 60950-1 (Ed.1); IEC 60950-1 (Ed.2); IEC 60950-1 (Ed.2)+A1+A2; UL 60950-1 (Ed.2); IEC 60950-1 (Ed.2)+A1; IEC 60950-1 (Ed.2)+A2; UL/CSA/EN/IEC/AS/NZS 60950-21; UL/CSA/EN/IEC/AS/NZS 60950-22; UL/CSA/EN/IEC/AS/NZS 60950-23; GB 4943.1; UL/CSA/EN/IEC/AS/NZS 62368-1; IEC 62368-1:2014; IEC 62368-1:2018; IEC 62368-1:2023; UL/CSA 62368-1:2014; EN 62368-1:2014 + A11:2017; UL/CSA 62368-1:2019; EN IEC 62368-1:2020 + A11:2020; IEC 62368-1:2023; EN IEC 62368-1-2024 + A11:2024; UL 62368-1:2019/R:2021-10; CSA C22.2 No. 62368-1:2019/U1:2021-10; UL 1741; UL 2056; UL 1012; UL 1310; IEC 60335-1:2020; IEC 60335-1:2010 + A1:2013+A2:2016; UL/CSA 60335-1:2016; UL/CSA/EN 60335-1; IEC 60335-2-6:2014/A1:2018
EN 60335-2-6:2015/A11:2020; CSA E60335-2-6:18; IEC/EN/CSA 60335-2-6; IEC 60335-2-7:2008/A2:2016; EN 60335-2-7:2010/A2:2019; CSA E60335-2-7:13; IEC/EN/CSA 60335-2-7; IEC 60335-2-11:2019; IEC 60335-2-11:2008/A2:2015; EN 60335-2-11:2010/A2:2018; CSA E60335-2-11:13; IEC/EN/CSA 60335-2-11; IEC 60335-2-12:2002/A2:2017; EN 60335-2-12: 2003/A2:2019; CSA 60335-2-12:20; IEC/EN/CSA 60335-2-12; IEC 60335-2-21:2012; IEC 60335-2-21:2012/AMD1:2018; IEC 60335-2-21:2022; EN 60335-2-21:2021 + A1:2021; EN 60335-2-21 2003 + A1 + A2:2008; IEC 60335-2-24:2010/A2:2017; CSA 60335-2-24:2022; UL 60335-2-24:2022; EN 60335-2-24:2010/A11:2020; IEC/EN/UL/CSA 60335-2-24; IEC 60335-2-29:2016; IEC 60335-2-29:2016/A1:2019; IEC 60335-2-29:2003; IEC 60335-2-29:2003/A2:2009; CAN/CSA E60335-2-29; EN 60335-2-29; IEC 60335-2-30:2009; IEC 60335-2-30:2009/A2:2021; IEC 60335-2-30; IEC 60335-2-37:2017; IEC 60335-2-37:2017/A2:2011; IEC 60335-2-37:2021; CSA E60335-2-37:2020; IEC/EN/CSA 60335-2-37; IEC 60335-2-38:2002
CSA 60335-2-52:2014; EN 60335-2-52:2003/A11:2010; IEC/EN/CSA 60335-2-52; IEC 60335-2-55:2021; IEC 60335-2-55:2002; IEC 60335-2-55:2002/A1:2008; CSA 60335-2-55:15; EN 60335-2-55:2003/A11:2018; IEC/EN/CSA 60335-2-55; IEC 60335-2-60:2023; IEC 60335-2-60:2017; IEC 60335-2-60:2002/A2:2008; EN 60335-2-60:2003/A12:2010; IEC/EN 60335-2-60; IEC 60335-2-64:2021; IEC 60335-2-64:2002/A2:2017; CSA E60335-2-64:20; EN 60335-2-64:200/A1:2002; IEC/EN/CSA 60335-2-64; IEC 60335-2-65:2023; IEC 60335-2-65:2002/A2:2015; CSA 60335-2-65:11; EN 60335-2-65:2003/A12:2022; IEC/EN/CSA 60335-2-65; IEC 60335-2-75:2012/A2:2018; IEC 60335-2-75:2002/A2:2008; EN 60335-2-75:2004A12:2010; IEC/EN 60335-2-75; IEC 60335-2-80:2015; IEC 60335-2-80:2002/A2:2008; EN 60335-2-80:2003/A2:2009; CSA 60335-2-80:17; IEC/EN/CSA 60335-2-80; IEC 60335-2-82:2017/A1:2020; IEC 60335-2-82:2002/A2:2015; EN 60335-2-82:2003/A2:2020; EN IEC 60335-2:2022; CSA 60335-2-82:20; IEC/EN/CSA 60335-2-82; IEC 60335-2-85:2002/A2:2017
MIL-STD-810; Methods 501 and 502; IEC 60601-1-11; IEC 62368-1; MIL-STD-810 Method 507; IEC 60255-21-1; ANSI C136.31; IEC 60068-2-6; MIL-STD-810 Method 516; IEC 60255-21-2
AS CISPR 11; AS/NZS CISPR 13; AS/NZS CISPR 14.1; AS/NZS CISPR 15; AS/NZS CISPR 22; AS/NZS CISPR 32; AS/NZS 61000.3.2; AS/NZS 61000.3.3; AS/NZS 61000.6.3; AS/NZS 61000.6.4; AS/NZS CISPR 14.2; AS/NZS 2772.2; AS/NZS 4268; AS/NZS 4769.1; AS/NZS 4769.2; AS/NZS 62040.2; CNS 13783-1:2013; CNS 13803:2018; CNS 13438:2006; CNS 15936:2016; RTTE01 (2020); LP0002 (2024); IFT-008-2015; NOM-208-SCFI-2016; TCVN 7189:2009; QCVN 18:2022/BTTTT; QCVN 54:2020/BTTTT; QCVN 55:2023/BTTTT; QCVN 60:2023/BTTTT; QCVN 86:2019/BTTTT; QCVN 96:2015/BTTTT; QCVN 103:2016/BTTTT; QCVN 112:2017/BTTTT; QCVN 118:2018/BTTTT; QCVN 130:2022/BTTTT; QCVN 100:2015/BTTTT; QCVN 94:2015/BTTTT; QCVN 72:2013/BTTTT; Technical Requirements for Electromagnetic Compatibility (RRA Announce 2018-99, Oct 12, 2018); KS C 9811; KS C IEC 60601-1-2; KS C 9814-1; KS C 9814-2; KS C 9815; KS C 9547; KS X 3124; KS X 3125; KS X 3126; KS X 3127; KS X 3130; KS X 3139; KS X 3135; KS X 3129; KS X 3140; KS C 9040-2; KS C 9832; KS C 9835; KS X 3140
KS C 9610-6-1; KS C 9610-6-2; KS C 9610-6-3; KS C 9610-6-4; HKCA 1006; HKCA 1007; HKCA 1008; HKCA 1020; HKCA 1033; HKCA 1035; HKCA 1039; HKCA 1042; HKCA 1043; HKCA 1044; HKCA 1049; IMDA TS WBA (October 2016); IMDA TS SRD (August 2021); VCCI-CISPR 32:2016; J55014-1; J55011; J55013; J55022; J55032; ARIB Standard STD-T33; ARIB Standard STD-T57; ARIB Standard STD-T66; ARIB Standard STD-T81; MIC Article 2-1; IEC 60601-1-2:2014; IEC 60601-1-2:2014+AMD1 2020; IEC 60601-1-2; EN 60601-1-2; BATT UL 4200A; IEC 62133-1:2017; CSA C22.2 No. 62133-1:2020; UL 62123-1 Ed.1 2025; IEC 62133-2:2017/A1:2021; CSA C22.2 No. 62133-2:2020; UL 62133-2 Ed.1 2024; UL 2054; UL 153; UL 1598; UL 2108; UL 8750; UL 1993; UL 1574; UL 8800; UL 8801; UL8802; UL 1838; UL 1573; CAN/CSA C22.2 No. 9.0S1; CAN/CSA C22.2 No. 250.0; CAN/CSA C22.2 No. 250.4; CAN/CSA C22.2 No. 250.13; CAN/CSA C22.2 No. 1993; CAN/CSA C22.2 No 250.1; CAN/CSA-E60598-1; CAN/CSA-E60598-2-4; CAN/CSA-E60598-2-5; IEC 60598-1:2020; IEC 60598-1:2014/A1:2017; IEC 60598-2-1: 2020; IEC 60598-2-1:1979/A1:1987
SANS 211:2010; SANS 214-1:2020; SANS 214-2:2009; SANS 2332:2017; SANS 2335:2018; SANS 61326-1:2007; SANS 61000-6-1:2005; SANS 61000-6-2:2005; SANS 61000-6-3:2011; SANS 61000-6-4:2011; CISPR 11; EN 55011; CISPR 13; EN 55013; CISPR 14-1; EN 55014-1; AS/NZS CISPR 14.1; CISPR 15; EN 55015; CISPR 16-2-1; CISPR 16-2-3; CISPR 22; EN 55022; AS/NZS CISPR 22; CISPR 32; EN 55032; AS/NZS CISPR 32; EN 50121-4; EN 61000-6-3; EN 61000-6-4; EN 61326-1; EN 61326-2-6; EN 61000-3-2; IEC 61000-3-2; JIS C 61000-3-2; EN 61000-3-3; IEC 61000-3-3; 47 CFR, FCC Part 15 C Unlicensed Transmitters (using ANSI C63.10-2013); ANSI C63.10-2013; ANSI C63.10-2020; ANSI C63.10-2020+Cor.1-2023; ANSI C63.10a-2024; 47 CFR, FCC Part 15 D Unlicensed Personal Communications Systems (using ANSI C63.17-2013); 47 CFR FCC Part 15 E, U-NII without DFS (using ANSI C63.10-2013); 47 CFR FCC Part 15 E, U-NII with DFS; KDB 905462 D02 April 8, 2016; 47 CFR FCC Part 15 F, Ultra-Wideband (using ANSI C63.10-2013); 47 CFR, FCC Part 15 H White Space Device (using ANSI C63.10-2013)
EPA ENERGY STAR Program Requirements for Uninterruptible Power Supplies (UPSs) (v 2.0); Uniform Test Method for Measuring the Energy Consumption of Battery Chargers incorporated in Appendix Y to Subpart B of 10 CFR Part 430; Uniform Test Method for Measuring the Energy Consumption of Battery Chargers incorporated in Appendix Y1 to Subpart B of 10 CFR Part 430; ENERGY STAR Test Method – Rev. Dec 2017; EPA ENERGY STAR Program Requirements for Water Coolers (v. 2.0); ENERGY STAR Test Method for Water Coolers (May 2013); IEC 62301 (2005, 2011); 62018 (2003); 62087 (2011); 62623 (2012); CEA 2037 (2009); CSA C381.1 (2008); C381.2-17; C62301 (2011); C802.2 (2011); 47 CFR, FCC Part 15, Subpart B (using ANSI C63.4-2014); ANSI C63.4-2014; 47 CFR, FCC Part 18 (using MP-5:1986); MP-5:1986; ICES-002; ICES-003; ICES-001; ICES-005; VCCI V-3 (up to 6 GHz); VCCI-CISPR 32:2016 (up to 6 GHz)
IEC 60598-2-2:2023; IEC 60598-2-2:2011; IEC 60598-2-4:2017; IEC 60598-2-5:2015; EN 60598-1:2015; EN IEC 60598-1:2021/A11:2022; EN 60598-2-1:1999; EN IEC 60598-2-1:2021; EN 60598-2-2:2012; EN IEC 60598-2-2:2022; EN 60598-2-4:2018; EN 60598-2-5:2015; UL/CSA/EN/IEC/AS/NZS 61010-1; EN 61010-1:2001; EN 61010-1: 2010 + A1:2019; IEC 61010-1:2001; IEC 61010-1:2010 + A1:2016; UL 61010-1:2004; UL 61010-1:2012/R:2019-01; CSA C22.2 No. 61010-1:2012 + A1:2018; IEC 61010-2-010:2014; IEC 61010-2-010:2019; EN 61010-2-010:2014; UL/CSA 61010-2-010:2019; EN IEC 61010-2-010:2020; UL/EN/CSA 61010-2-010; IEC 61010-2-081:2015; IEC 61010-2-081:2019; UL/CSA 61010-2-081:2019; EN IEC 61010-2-081:2020; UL/EN/CSA 61010-2-081; IEC 61010-2-101:2015; IEC 61010-2-101:2018; UL/CSA 61010-2-101:2019; EN 61010-2-101:2017; EN IEC 61010-2-101:20222/A11:2022; UL/EN/CSA 61010-2-101; UL 61010-2-051:2019; EN IEC 61010-2-051:2021/A11:2021; CAN/CSA-C22.2 No. 61010-2-051:2015; IEC 61010-2-051:2015; IEC 61010-2-201:2017; CAN C22.2 No. 61010-2-201:2018-02; UL 61010-2-201:2018/R:2022-08
ANSI C63.4a:2017; ANSI C63.4:2014; 47 Code of Federal Regulations; FCC KDB 974614, Appendix A, Table A.1; FCC MP-5 (February 1986); ANSI C63.10-2013; ANSI C63.17-2013; KDB 905462 D02 V02 April 8, 2016
ANSI C63.26-2015; ANSI/TIA-603-E 2016
Read from the A2LA scope documents we downloaded on 2026-10-27. Register refreshed 2026-11-20.
Scope as published by A2LA
18 lines
ISO/IEC 17025
Active2955.09
The scope document we hold says it is valid until 2027-08-31.
ISO/IEC 17025
Active2955.26
The scope document we hold says it is valid until 2027-08-31.
Location
Other Locations
1 other site in this organization
Labs with overlapping accredited scope in United States
- TUV SUD AmericaNew Brighton, MN · ~1,439 kmA2LAShares 4 accredited test methodsANSI C63.4-2014ANSI C63.4:2014CISPR 11
- TUV SUD AmericaSan Diego, CA · ~3,042 kmA2LAShares 4 accredited test methodsANSI C63.26-2015ANSI C63.4-2014CISPR 11
- TUV Rheinland of North AmericaPleasanton, CA · ~3,387 kmA2LAShares 3 accredited test methodsANSI C63.26-2015ANSI C63.4:2014RSS-GEN
- Intertek Testing Services NADuluth, GA · ~16 kmA2LAShares 2 accredited test methodsANSI C63.4:2014AS CISPR 11
- UL LLCDurham, NC · ~535 kmA2LAShares 2 accredited test methodsANSI C63.4-2014ANSI C63.4:2014
Accreditation data refreshed from the A2LA register on .