SERVICE DE PROTECTION RADIOLOGIQUE DES ARMEES
1 BIS RUE DU LIEUTENANT RAOUL BATANY, 92141, CLAMART, France
- Accredited standards
- 3
- COFRAC certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the COFRAC scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 3 standard numbers and the 2 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO 10704Water quality - Gross alpha and gross beta activity - Test method using thin source deposit
ISO 18589-2Measurement of radioactivity in the environment - Soil - Part 2: Guidance for the selection of the sampling strategy, sampling and pre-treatment of samples
NF S92-501
NF EN ISO 10704; NF ISO 18589-2; MO 06-01; MO 06-02
NF S 92-501; LCR MO 07-06
Read from the scope as published by COFRAC. Register refreshed 2026-11-20.
Scope as published by COFRAC
6 lines
ISO/IEC 17025
Active1-1225
Accredited scope, certificate 1-1225
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | - | ENVIRONNEMENT / QUALITE DE L'EAU - MATRICES SOLIDES - BIOINDICATEURS; LIEUX DE TRAVAIL / DOSIMETRIE DES TRAVAILLEURSShow page textExtracted from the scope document; tables may not line up. View scope for the original. Convention N° 2088
LAB FORM 37 – Révision 10 – applicable au 1er juillet 2025 Page 1/9
Section Laboratoires
ATTESTATION D’ACCREDITATION
ACCREDITATION CERTIFICATE
N° 1-1225 rév. 13
Le Comité Français d'Accréditation (Cofrac) atteste que :
The French Committee for Accreditation (Cofrac) certifies that :
SERVICE DE PROTECTION RADIOLOGIQUE DES ARMEES
N° SIREN : 151000023
Satisfait aux exigences de la norme NF EN ISO/IEC 17025 : 2017
Fulfils the requirements of the standard
et aux règles d’application du Cofrac pour les activités d’analyses/essais/étalonnages en :
and Cofrac rules of application for the activities of testing/calibration in :
ENVIRONNEMENT / QUALITE DE L'EAU - MATRICES SOLIDES - BIOINDICATEURS
ENVIRONMENT / WATER QUALITY - SOLID MATRICES - BIOINDICATORS
LIEUX DE TRAVAIL / DOSIMETRIE DES TRAVAILLEURS
WORKPLACES / WORKERS DOSEMETRY
réalisées par / performed by :
SERVICE DE PROTECTION RADIOLOGIQUE DES ARMEES
1 BIS RUE DU LIEUTENANT RAOUL BATANY
92141 CLAMART
et précisément décrites dans l’annexe technique jointe, à l’exclusion des activités réalisées dans les pays
listés dans le document GEN INF 16, dont la version en vigueur est disponible sur le site internet du Cofrac
(www.cofrac.fr).
and precisely described in the attached technical appendix, excluding activities performed in the countries listed in
the document GEN INF 16, the current version of which is available on our website (www.cofrac.fr).
L’accréditation suivant la norme internationale homologuée NF EN ISO/IEC 17025 est la preuve de la
compétence technique du laboratoire dans un domaine d’activités clairement défini et du bon
fonctionnement dans ce laboratoire d’un système de management adapté (cf. communiqué conjoint ISO-
ILAC-IAF en vigueur disponible sur le site internet du Cofrac www.cofrac.fr)
Accreditation in accordance with the recognised international standard NF EN ISO/IEC 17025 demonstrates the
technical competence of the laboratory for a defined scope and the proper operation in this laboratory of an
appropriate management system (see current Joint ISO -ILAC-IAF Communiqué available on Cofrac web site
www.cofrac.fr) .
Le Cofrac est signataire de l’accord multilatéral d’EA pour l’accréditation , pour les activités objets de la
présente attestation.
Cofrac is signatory of the European co -operation for Accreditation (EA) Multilateral Agreement for accreditation for
the activities covered by this certificate. | - |
| 2 | NF EN ISO 10704; NF ISO 18589-2; MO 06-01; MO 06-02 | Surface water | See scope document |
| 3 | Méthode interne MO 06-01; Méthode interne MO 06-02 | Flore terrestre et marine | See scope document |
| 4 | NF S 92-501; LCR MO 07-06 | Whole organism | See scope document |
| 5 | LAB REF 37; LDOS MO 101-01; LDOS MO 104-01; LDOS MO 101-02; LDOS MO 104-02 | Dosimètre OSL Inlight® individuel pour les photons (gamma, X) porté à la poitrine; Dosimètre OSL Inlight® individuel pour les bêtas porté à la poitrine; Dosimètre OSL Inlight® individuel pour les photons (gamma, X) porté en extrémité poignet | 0.1 to 10 mSv à Sv |
| 6 | - | Dosimètre Neutrak® 144-T individuel pour les neutrons porté à la poitrineShow page textExtracted from the scope document; tables may not line up. View scope for the original. LAB FORM 37 – Révision 10 – applicable au 1er juillet 2025 Page 8/9
# LIEUX DE TRAVAIL / DOSIMETRIE DES TRAVAILLEURS / Essais en dosimétrie externe en radioprotection (DOS_TRAV)
Exigences spécifiques pour l’accréditation des laboratoires chargés de procéder à la surveillance individuelle de l’exposition des travailleurs aux rayonnements ionisants (LAB REF 37)
Objet Caractéristique ou grandeur mesurée Principe de la méthode Références de méthode Remarques
Dosimètre Neutrak®
144-T individuel
pour les neutrons porté à la
poitrine
Détermination de l’équivalent de dose individuel
Hp(10)
Neutron thermique : inférieur à 0,5 eV
linéarité de 0,10 mSv à 2 mSv
de 0° à ± 60°
Neutron rapide : de 144 keV à 16,5 MeV
linéarité de 0,10 mSv à 20 mSv
de 0° à ± 60°
Détecteur solide de traces
nucléaires, développé par
attaque chimique puis comptage
du nombre de traces
proportionnel à la dose
Technique Neutrak :
- Mode opératoire LDOS MO 103-01 : Protocole
d’utilisation courante Neutrak
- Mode opératoire LDOS MO 103-02 : Protocole de
surveillance du système Neutrak
/
# Accréditation rendue obligatoire dans le cadre réglementaire français précisé par le texte cité en référence dans le document Cofrac LAB INF 99 disponible sur www.cofrac.fr | 0.1 to 20 mSv |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in France
- BIPEA - BUREAU INTERPROFESSIONNEL D'ETUDES ANALYTIQUESPARIS · ~7 kmCOFRACShares 1 accredited materialSurface water
- BUREAU VERITAS EXPLOITATIONCOURBEVOIE · ~9 kmCOFRACShares 1 accredited materialSurface water
- CARSO - LSEHL SITE DE SACLAYSACLAY · ~11 kmCOFRACShares 1 accredited materialSurface water
- AQUATYCIAALFORTVILLE · ~12 kmCOFRACShares 1 accredited materialSurface water
- FLASHLAB - SITE DE LONGJUMEAULONGJUMEAU · ~14 kmCOFRACShares 1 accredited materialSurface water
Accreditation data refreshed from the COFRAC register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the COFRAC entry linked above.