United States

Cleveland Electric

1776 Enterprise Parkway, 44087, Twinsburg, OH, United States

Visit website
A2LA 1658.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
1
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 1 standard number and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.

ASTM E220Standard Test Method for Calibration of Thermocouples By Comparison Techniques

Read from the A2LA scope document we downloaded on 2025-12-02. Register refreshed 2026-11-20.

Scope as published by A2LA

8 lines
A2LA

ISO/IEC 17025

Active

1658.01

The scope document we hold says it is valid until 2027-09-30.

View scope

Accredited scope, certificate 1658.01

LineMethodMatrixRange
1ISO/IEC 17025:2017; IEC 17025; ANSI/NCSL Z540-1-1994 CLEVELAND ELECTRIC LABORATORIES 1776-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1658.01) 08/07/2025 Page 2 of 7 Parameter/Equipment Range CMC2, 4 (±) Comments DC Current – Measure (0 to 100) µA 100 µA to 1 mA (1 to 10) mA (10 to 100) mA 100 mA to 1 A 0.028 % + 0.8 nA 0.004 % + 5 nA 0.007 % + 50 nA 0.005 % + 0.5 µA 0.013 % + 10 µA Keysight 3458A Resistance – Generate Up to 10 Ω (10 to 100) Ω 100 Ω to 1 kΩ (1 to 10) kΩ (10 to 100) kΩ 100 kΩ to 1 MΩ (1 to 10) MΩ (11 to 30) MΩ 0.078 % + 50 µΩ 0.0079 % + 500 µΩ 0.0014 % + 500 µΩ 0.0012 % + 5 mΩ 0.0012 % + 50 mΩ 0.0018 % + 2 Ω 0.0058 % + 100 Ω 0.058 % + 300 Ω Fluke 5520A, Keysight 3458A Resistance – Measure Up to 10 Ω (10 to 100) Ω 100 Ω to 1 kΩ (1 to 10) kΩ (10 to 100) kΩ 100 kΩ to 1 MΩ (1 to 10) MΩ (10 to 33) MΩ (33 to 100) MΩ 0.078 % + 50 µΩ 0.0079 % + 500 µΩ 0.0014 % + 500 µΩ 0.0012 % + 5 mΩ 0.0012 % + 50 mΩ 0.0018 % + 2 Ω 0.0058 % + 100 Ω 0.058 % + 1 kΩ 0.058 % + 1 kΩ Keysight 3458A Electrical Calibration of Thermocouple Indicating Systems – Measure Type B Type C Type E Type J Type K Type N Type R Type S Type T Type Ni/Ni-Mo Type – P II (500 to 3300) °F (0 to 4200) °F (-400 to 1800) °F (-340 to 2190) °F (-440 to 2500) °F (-440 to 2372) °F (32 to 3210) °F (32 to 3200) °F (-450 to 750) °F (32 to 2560) °F (32 to 2450) °F 0.72 °F 0.22 °F 0.14 °F 0.069 °F 0.10 °F 0.11 °F 0.35 °F 0.39 °F 0.22 °F 0.071 °F 0.11 °F Keysight 3458A, reference CJC
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1658.01) 08/07/2025 Page 3 of 7 Parameter/Equipment Range CMC2 (±) Comments Electrical Calibration of Thermocouple Indicating Systems – Generate Type B Type C Type E Type J Type K Type N Type R Type S Type T Type Ni/Ni-Mo Type - P II (500 to 3300) °F (0 to 4200) °F (-400 to 1800) °F (-340 to 2190) °F (-440 to 2500) °F (-440 to 2372) °F (32 to 3210) °F (32 to 3200) °F (-450 to 750) °F (32 to 2560) °F (32 to 2450) °F 0.72 °F 0.22 °F 0.14 °F 0.069 °F 0.10 °F 0.11 °F 0.35 °F 0.39 °F 0.22 °F 0.08 °F 0.11 °F Fluke 5520A, Keysight 3458A, reference CJC Electrical Calibration of RTD Indicating Systems – Measure Pt 385, 100 Ω Pt 385, 1000 Ω (32 to 1200) °F (32 to 1100) °F 0.15 °F 0.066 °F Keysight 3458A Electrical Calibration of RTD Indicating Systems – Generate Pt 385, 100 Ω Pt 385, 1000 Ω (-320 to 1200) °F (-320 to 1100) °F 0.15 °F 0.066 °F Keysight 3458A, Fluke5520A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1658.01) 08/07/2025 Page 4 of 7 Parameter/Range Frequency CMC2, 4 (±) Comments AC Current – Measure (0 to 100) µA 100 µA to 1 mA (1 to 10) mA (10 to 100) mA 100 mA to 1 A 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 0.029 % + 30 nA 0.003 % + 200 nA 0.015 % + 2 µA 0.007 % + 20 µA 0.093 % + 200 µA Keysight 3458A AC Current – Generate (30 to 100) µA 100 µA to 1 mA (1 to 10) mA (10 to 100) mA 100 mA to 1 A (1 to 3) A (3 to 20) A 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 0.029 % + 30 nA 0.003 % + 200 nA 0.015 % + 2 µA 0.007 % + 20 µA 0.093 % + 200 µA 0.14 % + 0.2 mA 0.14 % + 2 mA Keysight 3458A Fluke 5520A Fluke 5520A AC Voltage – Measure Up to 100 mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 700) V 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 0.07 % + 10 µV 0.07 % + 100 µV 0.07 % + 1 mV 0.07 % + 10 mV 0.09 % + 140 mV Keysight 3458A AC Voltage – Generate Up to 100 mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 700) V 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 0.07 % + 10 µV 0.07 % + 100 µV 0.07 % + 1 mV 0.07 % + 10 mV 0.09 % + 140 mV Fluke 5520A, Keysight 3458A
5ASTM E220-See scope document
6ASTM E 220-See scope document
7ASTM -E220-See scope document
8ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025; ANSI/NCSL Z540-1-1994 and R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

1776 Enterprise Parkway, Twinsburg, OH, 44087, US

41.29067, -81.45794

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.