What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 1 standard number and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.
ASTM E220Standard Test Method for Calibration of Thermocouples By Comparison Techniques
ASTM E220
ASTM E 220
Read from the A2LA scope document we downloaded on 2025-12-02. Register refreshed 2026-11-20.
Scope as published by A2LA
8 lines
ISO/IEC 17025
Active1658.01
The scope document we hold says it is valid until 2027-09-30.
Accredited scope, certificate 1658.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; IEC 17025; ANSI/NCSL Z540-1-1994 CLEVELAND ELECTRIC LABORATORIES 1776 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1658.01) 08/07/2025 Page 2 of 7
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
DC Current – Measure
(0 to 100) µA
100 µA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
0.028 % + 0.8 nA
0.004 % + 5 nA
0.007 % + 50 nA
0.005 % + 0.5 µA
0.013 % + 10 µA
Keysight 3458A
Resistance – Generate
Up to 10 Ω
(10 to 100) Ω
100 Ω to 1 kΩ
(1 to 10) kΩ
(10 to 100) kΩ
100 kΩ to 1 MΩ
(1 to 10) MΩ
(11 to 30) MΩ
0.078 % + 50 µΩ
0.0079 % + 500 µΩ
0.0014 % + 500 µΩ
0.0012 % + 5 mΩ
0.0012 % + 50 mΩ
0.0018 % + 2 Ω
0.0058 % + 100 Ω
0.058 % + 300 Ω
Fluke 5520A,
Keysight 3458A
Resistance – Measure
Up to 10 Ω
(10 to 100) Ω
100 Ω to 1 kΩ
(1 to 10) kΩ
(10 to 100) kΩ
100 kΩ to 1 MΩ
(1 to 10) MΩ
(10 to 33) MΩ
(33 to 100) MΩ
0.078 % + 50 µΩ
0.0079 % + 500 µΩ
0.0014 % + 500 µΩ
0.0012 % + 5 mΩ
0.0012 % + 50 mΩ
0.0018 % + 2 Ω
0.0058 % + 100 Ω
0.058 % + 1 kΩ
0.058 % + 1 kΩ
Keysight 3458A
Electrical Calibration of
Thermocouple Indicating
Systems
– Measure
Type B
Type C
Type E
Type J
Type K
Type N
Type R
Type S
Type T
Type Ni/Ni-Mo
Type – P II
(500 to 3300) °F
(0 to 4200) °F
(-400 to 1800) °F
(-340 to 2190) °F
(-440 to 2500) °F
(-440 to 2372) °F
(32 to 3210) °F
(32 to 3200) °F
(-450 to 750) °F
(32 to 2560) °F
(32 to 2450) °F
0.72 °F
0.22 °F
0.14 °F
0.069 °F
0.10 °F
0.11 °F
0.35 °F
0.39 °F
0.22 °F
0.071 °F
0.11 °F
Keysight 3458A,
reference CJC | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1658.01) 08/07/2025 Page 3 of 7
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration of
Thermocouple Indicating
Systems – Generate
Type B
Type C
Type E
Type J
Type K
Type N
Type R
Type S
Type T
Type Ni/Ni-Mo
Type - P II
(500 to 3300) °F
(0 to 4200) °F
(-400 to 1800) °F
(-340 to 2190) °F
(-440 to 2500) °F
(-440 to 2372) °F
(32 to 3210) °F
(32 to 3200) °F
(-450 to 750) °F
(32 to 2560) °F
(32 to 2450) °F
0.72 °F
0.22 °F
0.14 °F
0.069 °F
0.10 °F
0.11 °F
0.35 °F
0.39 °F
0.22 °F
0.08 °F
0.11 °F
Fluke 5520A,
Keysight 3458A,
reference CJC
Electrical Calibration of
RTD Indicating Systems –
Measure
Pt 385, 100 Ω
Pt 385, 1000 Ω
(32 to 1200) °F
(32 to 1100) °F
0.15 °F
0.066 °F
Keysight 3458A
Electrical Calibration of
RTD Indicating Systems –
Generate
Pt 385, 100 Ω
Pt 385, 1000 Ω
(-320 to 1200) °F
(-320 to 1100) °F
0.15 °F
0.066 °F
Keysight 3458A,
Fluke5520A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1658.01) 08/07/2025 Page 4 of 7
Parameter/Range
Frequency
CMC2, 4 (±)
Comments
AC Current – Measure
(0 to 100) µA
100 µA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
0.029 % + 30 nA
0.003 % + 200 nA
0.015 % + 2 µA
0.007 % + 20 µA
0.093 % + 200 µA
Keysight 3458A
AC Current – Generate
(30 to 100) µA
100 µA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
(1 to 3) A
(3 to 20) A
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
0.029 % + 30 nA
0.003 % + 200 nA
0.015 % + 2 µA
0.007 % + 20 µA
0.093 % + 200 µA
0.14 % + 0.2 mA
0.14 % + 2 mA
Keysight 3458A
Fluke 5520A
Fluke 5520A
AC Voltage – Measure
Up to 100 mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 700) V
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
0.07 % + 10 µV
0.07 % + 100 µV
0.07 % + 1 mV
0.07 % + 10 mV
0.09 % + 140 mV
Keysight 3458A
AC Voltage – Generate
Up to 100 mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 700) V
50 Hz
50 Hz
50 Hz
50 Hz
50 Hz
0.07 % + 10 µV
0.07 % + 100 µV
0.07 % + 1 mV
0.07 % + 10 mV
0.09 % + 140 mV
Fluke 5520A,
Keysight 3458A | ||
| 5 | ASTM E220 | - | See scope document |
| 6 | ASTM E 220 | - | See scope document |
| 7 | ASTM -E220 | - | See scope document |
| 8 | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025; ANSI/NCSL Z540-1-1994 and R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.