G.T. Michelli Company, LLC - HARAHAN
130 Brookhollow Esplanade, 70123, Harahan, LA, United States
Visit website- Scope lines
- 15
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 15 scope lines.
A2LA certificate 3601.01 · 15 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994 | - | to 12 in |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3601.01) Revised 12/06/2024 Page 2 of 14
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Length Standards
Up to 80 in
(6.7 + 3.3L) µin
P&W LabmasterTM 1000 A
Parallels, Straight Edges,
1-2-3 Blocks –
Parallel & Straight
Up to 40 in
45 μin
Amplifier, gage probe &
surface plate
Precision Levels –
Bubble Levels
Inclinometers, Digital
Protractors
Up to 15 in
Up to 180 °
100 µin
210 sec of arc
Precision height gage
Sine plate &
gage blocks
Rigid Rules
Up to 18 in
1200 µin
P&W LabmasterTM w/
Grade 0 gage blocks
Ring Gauges
Up to 18 in
(13 + 2.8L) µin
P&W LabmasterTM 1000 A
Tapes
Up to 95 ft
(2200 + 55L) µin
P&W LabmasterTM w/
Grade 0 gage blocks
Thickness Gauges
Up to 20 in
(7 + 3.1L) µin
P&W LabmasterTM 1000 A
Surface Plates3 –
Flatness
Repeatability
(12 to 102) in diagonal
(0.000 02 to 0.002) in
(10√DL) µin
31 µin
Electronic level system
Repeat-o-meter
Threaded Plug Gages –
Major Diameter
Pitch Diameter
Up to 16 in
Up to 16 in
(13 + 2.7D) µin
(45 + 1.4D) µin
P&W LabmasterTM 1000 A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3601.01) Revised 12/06/2024 Page 3 of 14
II. Electrical DC/Low Frequency
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
DC Voltage – Generate3
Fixed Point
Up to 220 mV
(0.22 to 2.2) V
(2.2 to 11) V
(11 to 22) V
(22 to 220) V
(220 to 1100) V
Up to 330 mV
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
10 V
7 µV/V + 0.4 µV
3.7 µV/V + 0.7 µV
2.7 µV/V + 2.5 µV
1.4 µV/V + 4 µV
3.8 µV/V + 40 µV
4.8 µV/V + 400 µV
2.4 µV/V + 3 µV
2.1 µV/V + 5 µV
4.5 µV/V + 50 µV
5.5 µV/V + 500 µV
16 µV/V + 1500 µV
0.71 µV/V
Fluke 5730A
Fluke 5502A
Fluke 732C
DC Current – Generate3
Up to 220 µA
(0.22 to 2.2) mA
(2.2 to 22) mA
(22 to 220) mA
(0.22 to 2.2) A
Up to 330 µA
(0.33 to 33) mA
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 1.1) A
(1.1 to 3) A
(3 to 11) A
(11 to 20.5) A
(10 to 16.5) A
(16.5 to 150) A
(150 to 1025) A
40 µA/A + 6 nA
36 µA/A + 7 nA
36 µA/A + 40 nA
46 µA/A + 0.7 nA
84 µA/A + 12 nA
0.017 % + 0.07 µA
0.002 % + 0.45 µA
0.016 % + 3.6 µA
0.022 % + 36 µA
0.002 % + 44 µA
0.11 % + 1.2 mA
0.08 % + 7.5 mA
2 % + 200 mA
0.25 % + 2 mA
0.26 % + 15 mA
0.28 % + 50 mA
Fluke 5730A
Fluke 5502A
Fluke 5502A,
50 turn coil
DC Voltage – Measure3
Up to 200 mV
Up to 2 V
Up to 20 V
Up to 200 V
Up to 1000 V
(1 to 40) kV
(5 to 100) kV
0.65 µV/V + 2.0 µV
3.5 µV/V + 0.3 µV
7.7 µV/V + 0.05 µV
27 µV/V + 5.0 µV
300 µV/V + 25 µV
0.034 kV
0.011 kV
Fluke 8588A
HP 34401A w/80K-40
high voltage probe
Haefely-Hipotronics
KVM100-W | ||
| 4 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3601.01) Revised 12/06/2024 Page 4 of 14
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
AC Voltage – Generate3
Up to 33 mV
(33 to 330) mV
(0.33 to 3.3) V
(3.3 to 33) V
(33 to 330) V
(330 to 1020) V
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(10 to 45) Hz
45 Hz to 10 kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 10) kHz
(10 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
0.15 % + 20 µV
0.10 % + 20 µV
0.15 % + 20 µV
0.20 % + 20 µV
0.4 % + 33 µV
1.2 % + 60 µV
0.055 % + 20 µV
0.033 % + 20 µV
0.073 % + 20 µV
0.10 % + 40 µV
0.23 % + 170 µV
0.50 % + 330 µV
0.055 % + 60 µV
0.11 % + 60 µV
0.07 % + 60 µV
0.06 % + 60 µV
0.15 % + 0.2 mV
0.50 % + 0.9 mV
0.017 % + 0.8 mV
0.058 % + 0.6 mV
0.088 % + 0.6 mV
0.10 % + 0.6 mV
0.23 % + 0.2 mV
0.052 % + 3 mV
0.091 % + 9 mV
0.10 % + 9 mV
0.12 % + 9 mV
0.24 % + 80 mV
0.051 % + 20 mV
0.08 % + 20 mV
0.09 % + 20 mV
Fluke 5502A | to 1020 V |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3601.01) Revised 12/06/2024 Page 5 of 14
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
AC Current – Generate3
Up to 330 µA
(0.33 to 3.3) mA
(3.3 to 33) mA
(33 to 330) mA
(0.33 to 1.1) A
(1.1 to 3) A
(3 to 11) A
(11 to 20.5) A
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 20) Hz
(20 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 30) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 45) Hz
45 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
(45 to 100) Hz
100 Hz to 1 kHz
(1 to 5) kHz
0.23 % + 0.1 µA
0.25 % + 0.1 µA
0.24 % + 0.1 µA
0.36 % + 0.15 µA
0.85 % + 0.2 µA
1.6 % + 0.4 µA
0.29 % + 0.15 µA
0.24 % + 0.15 µA
0.22 % + 0.15 µA
0.28 % + 0.2 µA
0.58 % + 0.3 µA
1.0 % + 0.6 µA
0.18 % + 2 µA
0.09 % + 2 µA
0.05 % + 2 µA
0.08 % + 2 µA
0.20 % + 3 µA
0.42 % + 4 µA
0.18 % + 20 µA
0.09 % + 20 µA
0.04 % + 20 µA
0.10 % + 50 µA
0.20 % + 0.1 mA
0.42 % + 0.2 mA
0.44 % + 0.1 mA
0.15 % + 0.1 mA
0.62 % + 1 mA
2.5 % + 5 mA
0.19 % + 0.1 mA
0.16 % + 0.1 mA
2.1 % + 1 mA
3.2 % + 5 mA
0.41 % + 0.1 mV
0.23 % + 0.1 mV
3.0 % + 1 mV
0.16 % + 0.1 mV
0.19 % + 0.1 mV
3.0 % + 1 mV
Fluke 5502A with
LCOMP off | ||
| 6 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3601.01) Revised 12/06/2024 Page 6 of 14
Parameter/Range
Frequency
CMC2, 5, 6 (±)
Comments
AC Voltage –Measure
(0 to 200) mV
(0 to 2) V
(0 to 20) V
(5 to 100) kV RMS
(5 to 100) kV Peak/√2
(0 to 200) V
(0 to 1000) V
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(10 to 40) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
(50 to 420) Hz
(50 to 420) Hz
(40 to 100) Hz
100 Hz to 2 kHz
(2 to 10) kHz
(10 to 30) kHz
(30 to 100) kHz
40 Hz to 5 kHz
0.027 % + 7.3 µV
0.019 % + 7.2 µV
0.018 % + 6.0 µV
0.017 % + 7.0 µV
0.036 % + 6.4 µV
0.06 % + 30 µV
0.029 % + 36 µV
0.029 % + 41 µV
0.006 % + 43 µV
0.031 % + 39 µV
0.031 % + 82 µV
0.030 % + 390 µV
0.043 % + 420 µV
0.13 % + 5.4 mV
0.015 % + 460 µV
0.015 % + 400 µV
0.015 % + 420 µV
0.015 % + 380 µV
0.015 % + 970 µV
0.016 % + 6.2 mV
0.022 kV
0.11 kV
0.015 % + 1.4 mV
0.015 % + 2.8 mV
0.015 % + 4.0 mV
0.015 % + 2.4 mV
0.016 % + 250 mV
0.029 % + 250 mV
Fluke 8508A
Haefely-Hipotronics
KVM100-W
Fluke 8508A
AC Current –
Measure
9,10
Up to 200 µA
Up to 2 mA
10 Hz to 10 kHz
(10 To 30) kHz
10 Hz to 10 kHz
(10 to 30) kHz
0.026 %
0.065 %
0.080 %
0.11 %
Fluke 8508A | 0 to 1000 V |
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3601.01) Revised 12/06/2024 Page 7 of 14
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Capacitance – Generate3
(220 to 400) pF
(0.4 to 1.1) nF
(1.1 to 3.3) nF
(3.3 to 11) nF
(11 to 33) nF
(33 to 110) nF
(110 to 330) nF
(0.33 to 1.1) µF
(1.1 to 3.3) µF
(3.3 to 11) µF
(11 to 33) µF
(33 to 110) µF
(110 to 330) µF
(0.33 to 1.1) mF
(1.1 to 3.3) mF
(3.3 to 11) mF
(11 to 33) mF
(33 to 110) mF
0.43 % + 0.01 nF
0.61 % + 0.01 nF
0.73 % + 0.01 nF
0.56 % + 0.01 nF
0.58 % + 0.1 nF
0.56 % + 0.1 nF
0.58 % + 0.3 nF
0.58 % + 1 nF
0.58 % + 3 nF
0.62 % + 10 nF
0.58 % + 30 nF
0.57 % + 0.1 µF
0.70 % + 0.3 µF
0.71 % + 1 µF
0.48 % + 3 µF
0.46 % + 10 µF
0.91 % + 30 µF
1.3 % + 100 µF
Fluke 5502A
Resistance – Generate3
Up to 11 Ω
(11 to 33) Ω
(33 to 110) Ω
(110 to 330) Ω
(0.33 to 1.1) kΩ
(1.1 to 3.3) kΩ
(3.3 to 11) kΩ
(11 to 33) kΩ
(33 to 110) kΩ
(110 to 330) kΩ
(0.33 to 1.1) MΩ
(1.1 to 3.3) MΩ
(3.3 to 11) MΩ
(11 to 33) MΩ
(33 to 110) MΩ
(110 to 330) MΩ
(0.33 to 1.1) GΩ
0.025 % + 0.001 Ω
0.014 % + 0.0015 Ω
0.01 % + 0.0014 Ω
0.01 % + 0.002 Ω
0.01 % + 0.002 Ω
0.01 % + 0.02 Ω
0.01 % + 0.02 Ω
0.01 % + 0.2 Ω
0.012 % + 0.2 Ω
0.012 % + 2 Ω
0.015 % + 2 Ω
0.015 % + 30 Ω
0.06 % + 50 Ω
0.10 % + 2.5 kΩ
0.55 % + 3 kΩ
0.52 % + 0.1 MΩ
1.3 % + 0.5 MΩ
Fluke 5502A
Resistance – Generate3
(Fixed Values)
25 Ω
100 Ω
200 Ω
400 Ω
6.4 µΩ/Ω
5.3 µΩ/Ω
5 µΩ/Ω
5 µΩ/Ω
IET Labs SRL Resistors | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3601.01) Revised 12/06/2024 Page 8 of 14
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Resistance – Generate3
(Fixed Values) (cont)
1 kΩ
10 kΩ
100 kΩ
1 MΩ
10 MΩ
100 MΩ
1 GΩ
10 GΩ
100 GΩ
1 TΩ
10 TΩ
0.015 kΩ
0.015 kΩ
0.083 kΩ
0.015 MΩ
0.083 MΩ
0.083 MΩ
0.016 GΩ
0.027 GΩ
0.36 GΩ
0.58 GΩ
0.60 GΩ
IET Labs VRS-100-11-
1K-BP
Resistance – Measure
Up to 2 Ω
Up to 20 Ω
Up to 200 Ω
Up to 2 kΩ
Up to 20 kΩ
Up to 200 kΩ
Up to 2 MΩ
Up to 20 MΩ
Up to 200 MΩ
Up to 2 GΩ
41 µΩ /Ω + 7.6 mΩ
0.009 % + 6.4 mΩ
45 µΩ /Ω + 12 mΩ
0.012 % + 31 mΩ
30 µΩ /Ω + 150 mΩ
77 µΩ /Ω + 1.7 Ω
0.005 % + 43 Ω
0.03 % + 990 Ω
0.04 % + 15 kΩ
2.0 % + 450 kΩ
Fluke 8508A
Electrical Calibration of
Thermocouple Indicators3
– Generate & Measure
Type E
Type J
Type K
Type T
(-250 to -100) °C
(-100 to -25) °C
(-25 to 350) °C
(350 to 650) °C
(650 to 1000) °C
(-210 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
0.50 °C
0.16 °C
0.14 °C
0.16 °C
0.21 °C
0.28 °C
0.17 °C
0.15 °C
0.18 °C
0.24 °C
0.33 °C
0.19 °C
0.17 °C
0.26 °C
0.40 °C
0.63 °C
0.24 °C
0.16 °C
0.14 °C
Fluke 5502A | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3601.01) Revised 12/06/2024 Page 9 of 14
Parameter/Equipment
Range
CMC2 (±)
Comments
Electrical Calibration of
RTD Indicators3 – Generate
Pt 385, 100 Ω
(-200 to -80) °C
(-80 to 0) °C
Up to 100 °C
(100 to 300) °C
(300 to 400) °C
(400 to 630) °C
(630 to 800) °C
0.07 °C
0.07 °C
0.10 °C
0.13 °C
0.15 °C
0.17 °C
0.33 °C
Fluke 5502A
Oscilloscope3 –
DC Volt Function
Into 50 Ω
Into 1 MΩ
Square Wave Signal
10 Hz to 10 kHz
Into 50 Ω
Into 1 MΩ
Level Sinewave Signal
5 mV to 5.5 V
Into 50 Ω
Time Markers
Into 50 Ω 1 V-pk
Up to 6.6 V
(1 to 2.5) mV
(2.5 to 500) mV
(1 to 2.2) V
(2.3 to 11) V
(12 to 130) V
1 mV to 6.6 V
(1 to 25) mV
(26 to 110) mV
(111 to 500) mV
(1 to 2.2) V
(2.3 to 11) V
(11 to 130) V
50 kHz
51 kHz to 100 MHz
(101 to 300) MHz
(301 to 600) MHz
5 s to 2 ns
0.23 mV
0.014 mV
0.019 mV
0.082 mV
0.27 mV
1.1 mV
0.43 mV
0.045 mV
0.018 mV
0.061 mV
0.24 mV
0.35 mV
17 mV
0.024 mV
0.093 mV
0.11 mV
0.87 mV
0.05 ns
Fluke 5502A/SC600 | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3601.01) Revised 12/06/2024 Page 10 of 14
V. Mechanical
Parameter/Equipment
Range
CMC2 (±)
Comments
Scales & Balances3
100 g
50 g
20 g
10 g
(1 to 5) g
(1 to 500) mg
22.7 kg (50 lb)
11.34 kg (25 lb)
4.54 kg (10 lb)
2.27 kg (5 lb)
25 kg
20 kg
10 kg
5 kg
2 kg
1 kg
500 g
200 g
100 g
50 g
20 g
10 g
5 g
3 g
2 g
1 g
500 mg
300 mg
200 mg
100 mg
50 mg
20 mg
10 mg
5 mg
3 mg
2 mg
1 mg
30 µg
15 µg
9 µg
6 µg
4 µg
1.2 µg
15 mg
4.8 mg
1.3 mg
0.66 mg
8.4 mg
9.1 mg
1.5 mg
0.85 mg
0.46 mg
0.13 mg
68 µg
40 µg
24 µg
9.6 µg
5.6 µg
5.0 µg
3.5 µg
2.9 µg
2.1 µg
1.8 µg
1.3 µg
1.0 µg
1.0 µg
1.0 µg
1.0 µg
0.66 µg
0.76 µg
0.5 µg
0.41 µg
0.38 µg
0.43 µg
Class 0 weights
Class 1 weights | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3601.01) Revised 12/06/2024 Page 11 of 14
Parameter/Equipment
Range
CMC2, 5, 8 (±)
Comments
Scales & Balances3
(cont)
Truck & Rail Scales
Tank & Hopper Scales
– Force Method
(1 to 5) kg
500 g
(1 to 200) g
100 mg
1 kg
(1 to 500) g
453.6 kg (1000 lb)
226.8 kg (500 lb)
22.7 kg (50 lb)
11.34 kg (25 lb)
4.54 kg (10 lb)
2.27 kg (5 lb)
0.91 kg (2 lb)
0.46 kg (1 lb)
0.23 kg (0.5 lb)
500 kg
200 kg
25 kg
20 kg
10 kg
5 kg
2 kg
1 kg
500 g
2268 kg (5000 lb)
2721.5 kg (6000 lb)
(6000 to 200 000) lb
Up to 200 000 lb
0.11 mg
0.10 mg
82 µg
1.2 µg
0.82 g
0.82 mg
11 g
2.8 g
580 mg
210 mg
120 mg
27 mg
11 mg
8.5 mg
2.3 mg
7 g
3 g
630 mg
280 mg
110 mg
0.78 mg
0.44 mg
0.12 mg
0.069 mg
170 g
230 g
0.0012 %
0.008 %
Class 2 weights
Class 4 weights
Class F weights
(Class 5/6)
Test cart
Class F test cart
& weight blocks
Load cells
Force – Measuring
Equipment
Compression
Up to 2 ozf
(2 to 8) ozf
(8 to 16) ozf
(16 to 24) ozf
(24 to 32) ozf
(32 to 40) ozf
0.82 ozf
1.1 ozf
2.0 ozf
2.9 ozf
3.8 ozf
4.7 ozf
Force transducers | ||
| 12 | ASTM Class 5 & 6 | - | See scope document |
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3601.01) Revised 12/06/2024 Page 13 of 14
VII. Thermodynamics
Parameter/Equipment
Range CMC2, 8 (±) Comments
Temperature – Measure3
(-197 to 0) °C
Up to 157 °C
(157 to 232) °C
(232 to 420) °C
(420 to 660) °C
(-197 to 0) °C
Up to 157 °C
(157 to 232) °C
(232 to 420) °C
0.027 °C
0.027 °C
0.027 °C
0.029 °C
0.053 °C
0.017 °C
0.017 °C
0.017 °C
0.026 °C
Fluke 9144 field
metrology well with
Fluke 5609 PRT
Fluke 1502A,
5616 PRT
Temperature –
Measuring Equipment
Up to 50 °C
(50 to 200) °C
(200 to 420) °C
(420 to 550) °C
(550 to 660) °C
0.08 °C
0.11 °C
0.14 °C
0.17 °C
0.2 °C
Fluke 9144 field
metrology well
Infrared Temperature –
Measuring Equipment
3
35 °C
(35 to 100) °C
(100 to 200) °C
(200 to 350) °C
(350 to 500) °C
0.45 °C
0.63 °C
0.90 °C
1.4 °C
2.1 °C
Fluke 4181 Blackbody -
emissivity 0.95
wavelength 8 to 14 µm
Humidity – Measure
(11 to 49) % RH
(50 to 79) % RH
80 % RH
0.61 % RH
0.68 % RH
0.74 % RH
Vaisala HM45/HMP113
temp/humidity meter
w/probe
VIII. Time & Frequency
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Frequency – Measuring
Equipment3
(0.01 to 119.99) Hz
(120 to 1199.9) Hz
(1.2 to 11.999) kHz
(12 to 119.99) kHz
0.004 % + 4 mHz
0.003 % + 30 mHz
0.003 % + 300 mHz
0.0024 % + 3 Hz
Fluke 5502A
________________________________
1 This laboratory offers commercial calibration service and field calibration service. | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 3601.01) Revised 12/06/2024 Page 14 of 14
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavio r of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of CMC, L is the numerical value of the nominal length in inches, D is diameter in inches,
and DL is the Diagonal length in inches.
5 In the statement of CMC, percent is to be read as percent of reading.
6 The stated measured values are determined using the indicated instrument (see Comments). This
capability is suitable for the calibration of the devices intended to measure or generate the measured value
in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a
percent or fraction of the reading plus a fixed floor specification.
7 This scope meets A2LA’s P112 Flexible Scope Policy.
8 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
9 Above 1 kHz interpolate the uncertainty (Ui) between frequencies fupper and flower using: Ui = Ulower + (fi –
flower) × (Uupper – Ulower) ÷ (fupper – flower)
10 Add 20 µ/A if relative humidity is >50%RH | ||
| 15 | ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- G.T. Michelli Company, LLC - BATON ROUGEBaton Rouge, LA · ~110 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- JM Test Systems, LLC.Baton Rouge, LA · ~110 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- Cal-TecBroussard, LA · ~171 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- G.T. Michelli Company, LLC - SEMMESSemmes, AL · ~209 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
- G.T. Michelli Company, LLC - JACKSONJackson, MS · ~262 kmA2LAShares 1 accredited test methodANSI/NCSL Z540-1-1994
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.