JianYan Testing Group Shenzhen Co.,
No. 101, Building 8, Innovation Wisdom Port, No. 155 Hongtian Road, Huangpu Community, Shenzhen, Guangdong, People's Republic of China, Shenzhen, Guangdong, China
Visit website- Accredited standards
- 81
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 81 standard numbers and the 41 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 61000 series23
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)+1 national
National versions in the same scope
AS/NZS 61000.3.2identical to it
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection+1 national
National versions in the same scope
AS/NZS 61000.3.3identical to it
IEC 61000-3-11Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current ≤ 75 A and subject to conditional connection
IEC 61000-3-12Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-4-12Electromagnetic Compatibility (EMC) - Part 4-12: Testing and measurement techniques - Ring wave immunity test
Show all 23
IEC 61000-4-13Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics including mains signalling at a.c. power port, low frequency immunity tests
IEC 61000-4-14
IEC 61000-4-17
IEC 61000-4-27
IEC 61000-4-28
IEC 61000-4-29Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
IEC 61000-4-34
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments+1 national
National versions in the same scope
AS/NZS 61000.6.3national version with changes
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
IEC16
IEC 60086-4
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and testsExclusion+1 national
Limits written next to it
EN 60601-1-2 (excluding Proximity magnetic fields)
IEC 60601-1-2 (excluding
National versions in the same scope
AS IEC 60601.1.2probably the same standard; matched by number only
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61326-2-6Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical electrical equipment
IEC 61547Equipment for general lighting purposes - EMC immunity requirements
IEC 61851-21-2
IEC 62133-1
IEC 62133-2Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications - Part 2: Lithium systems
IEC 62209-1
IEC 62209-2
IEC 62232
IEC 62233Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements+1 national
National versions in the same scope
AS/NZS 62368.1national version with changes
IEC 62368-3Exclusion
Limits written next to it
BS EN IEC 62368-3 (all excluding
IEC 62479Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
ETSI12
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-5
ETSI EN 301 489-6
ETSI EN 301 489-9
ETSI EN 301 489-17
ETSI EN 301 489-19
ETSI EN 301 489-33
ETSI EN 301 489-34
ETSI EN 301 489-50
ETSI EN 301 489-52
ETSI TS 138 114
CISPR8
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS CISPR 11national version with changes
CISPR 13Sound and television broadcast receivers and associated equipment - Radio disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS/NZS CISPR 13identical to it
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+2 national
National versions in the same scope
AS CISPR 14.1national version with changes
AS/NZS CISPR 14-1national version with changes
CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard+1 national
National versions in the same scope
AS/NZS CISPR 14.2national version with changes
CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment+2 national
National versions in the same scope
AS CISPR 15national version with changes
AS/NZS CISPR 15national version with changes
CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurement
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+1 national
National versions in the same scope
AS/NZS CISPR 32identical to it
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements
EN8
EN 957-6
EN 50360
EN 50364
EN 50371
EN 50385
EN 50566
EN 50663Generic standard for assessment of low power electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (10 MHz - 300 GHz)
EN 50665
IEC 60335 series6
IEC 60335-1Household and similar electrical appliances - Safety - Part 1: General requirements+1 national
National versions in the same scope
AS/NZS 60335.1national version with changes
IEC 60335-2-29+1 national
National versions in the same scope
AS/NZS 60335.2.29national version with changes
IEC 60335-2-32Exclusion+1 national
Limits written next to it
BS EN IEC 60335-2-32 (all excluding clause 22.46 and
National versions in the same scope
AS/NZS 60335.2.32identical to it
IEC 60335-2-65+1 national
National versions in the same scope
AS/NZS 60335.2.65identical to it
IEC 60335-2-80+1 national
National versions in the same scope
AS/NZS 60335.2.80national version with changes
IEC 60335-2-98+1 national
National versions in the same scope
AS/NZS 60335.2.98national version with changes
IEC 61558 series3
IEC 61558-1+1 national
National versions in the same scope
AS/NZS 61558.1national version with changes
IEC 61558-2-6+1 national
National versions in the same scope
AS/NZS 61558.2.6probably the same standard; matched by number only
IEC 61558-2-16+1 national
National versions in the same scope
AS/NZS 61558.2.16probably the same standard; matched by number only
Other standards5
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ANSI/TIA-603-E
FCC PART 15Radio Frequency Devices
ISO 20957-1Stationary training equipment - Part 1: General safety requirements and test methods
ISO 20957-6Stationary training equipment - Part 6: Treadmills, additional specific safety requirements and test methods
47 CFR Part 15B; 47 CFR Part 18; ANSI C63.4:2014; ANSI C63.10:2013; ANSI C63.10:2020; ANSI C63.10-2020+Cor1-2023; ANSI C63.10-2020+Cor1-2023+C63.10a-2024; ANSI C63.17:2013; ICES-001; ICES-003; ICES-005; ICES-006; EN 55011; EN 55013; EN 55014-1; EN IEC 55014-1; EN 55032; EN 55015; EN IEC 55015; BS EN 55011; BS EN 55013; BS EN 55014-1; BS EN IEC 55014-1; BS EN 55032; BS EN 55015; BS EN IEC 55015; J55011; J55014-1; J55015; J55032; CISPR 11; CISPR 13; CISPR 14-1; CISPR 15; CISPR 32; AS CISPR 11; AS/NZS CISPR 13; AS/NZS CISPR 14-1; AS CISPR 14.1; AS/NZS CISPR 32; AS/NZS CISPR 15; AS CISPR 15; HKTA 1007; EN 61000-3-2; IEC 61000-3-2; EN IEC 61000-3-2; BS EN 61000-3-2; BS EN IEC 61000-3-2; EN 61000-3-12; IEC 61000-3-12; BS EN 61000-3-12; AS/NZS 61000.3.2; EN 61000-3-3; IEC 61000-3-3; BS EN 61000-3-3; EN 61000-3-11; EN IEC 61000-3-11; IEC 61000-3-11; BS EN IEC 61000-3-11; AS/NZS 61000.3.3; EN 61000-4-2; IEC 61000-4-2:2008; IEC 61000-4-2; BS EN 61000-4-2
EN 61000-4-3; IEC 61000-4-3; BS EN 61000-4-3; BS EN IEC 61000-4-3; EN 61000-4-4; IEC 61000-4-4; BS EN 61000-4-4; EN 61000-4-5; IEC 61000-4-5; BS EN 61000-4-5; EN 61000-4-6; IEC 61000-4-6; BS EN 61000-4-6; EN 61000-4-11; EN IEC 61000-4-11; IEC 61000-4-11; BS EN 61000-4-11; BS EN IEC 61000-4-11; EN 61000-4-8; IEC 61000-4-8; BS EN 61000-4-8; EN 61000-4-12; IEC 61000-4-12; BS EN 61000-4-12; EN 61000-4-13; IEC 61000-4-13; BS EN 61000-4-13; EN 61000-4-14; IEC 61000-4-14; EN 61000-4-17; IEC 61000-4-17; EN 61000-4-27; IEC 61000-4-27; EN 61000-4-28; IEC 61000-4-28; EN 61000-4-29; IEC 61000-4-29; EN 61000-4-34; IEC 61000-4-34
IEC 61000-6-1; IEC 61000-6-2; IEC 61000-6-3; IEC 61000-6-4; IEC 61547; IEC 61326-1; IEC 61326-2-6; IEC 60601-1-2; EN 61000-6-1; EN IEC 61000-6-1; EN 61000-6-2; EN IEC 61000-6-2; EN 61000-6-3; EN 61000-6-4; EN 55024; EN 55035; EN 55014-2; EN IEC 55014-2; EN 61547; EN IEC 61547; EN 61326-1; EN IEC 61326-1; EN 61326-2-6; EN IEC 61326-2-6; EN IEC 61000-6-3; EN IEC 61000-6-4; EN 60601-1-2; CISPR 24; CISPR 35; BS EN 61000-6-1; BS EN IEC 61000-6-1; BS EN 61000-6-2; BS EN IEC 61000-6-2; BS EN 61000-6-3; BS EN IEC 61000-6-3; BS EN 61000-6-4; BS EN IEC 61000-6-4; BS EN 55024; BS EN 55035; BS EN 55014-2; BS EN IEC 55014-2; BS EN 61547; BS EN 61326-1; BS EN IEC 61326-1; BS EN 61326-2-6; BS EN IEC 61326-2-6; BS EN 60601-1-2; CISPR 14-2; AS/NZS CISPR 14.2; AS/NZS 61000.6.3; AS IEC 60601.1.2; IEC 61851-21-2; EN IEC 61851-21-2; EN 301 489-1; EN 301 489-3; EN 301 489-5; EN 301 489-6; EN 301 489-9; EN 301 489-17; EN 301 489-19; EN 301 489-33; EN 301 489-34; EN 301 489-50; EN 301 489-52; ETSI TS 138 114; EN 62368-1; BS EN 62368-1; IEC 62368-1; UL 62368-1; AS/NZS 62368.1; J62368-1; EN IEC 62368-1; BS EN IEC 62368-1; IEC 62368-3; EN IEC 62368-3; BS EN IEC 62368-3; IEC 62233; EN 62233; BS EN 62233; IEC 60335-1; EN 60335-1; BS EN 60335-1; AS/NZS 60335.1; J60335-1
IEC 60335-2-32; EN 60335-2-32; BS EN 60335-2-32; AS/NZS 60335.2.32; J60335-2-32; EN IEC 60335-2-32; BS EN IEC 60335-2-32; IEC 60335-2-65; EN 60335-2-65; BS EN 60335-2-65; AS/NZS 60335.2.65; J60335-2-65; IEC 60335-2-80; EN 60335-2-80; BS EN 60335-2-80; AS/NZS 60335.2.80; J60335-2-80; IEC 60335-2-98; EN 60335-2-98; BS EN 60335-2-98; AS/NZS 60335.2.98; J60335-2-98; IEC 60335-2-29; EN IEC 60335-2-29; BS EN IEC 60335-2-29; AS/NZS 60335.2.29; J60335-2-29; IEC 61558-1; EN IEC 61558-1; AS/NZS 61558.1; J61558-1; IEC 61558-2-6; EN IEC 61558-2-6; AS/NZS 61558.2.6; J61558-2-6; IEC 61558-2-16; EN IEC 61558-2-16; AS/NZS 61558.2.16; J61558-2-16; ISO 20957-1; EN ISO 20957-1; BS EN ISO 20957-1; ISO 20957-6; EN 957-6; BS EN 957-6; UL 1647; IEC 62133-1; EN 62133-1; BS EN 62133-1; UL 62133-1; IEC 62133-2; EN 62133-2; BS EN 62133-2; UL 62133-2; IEC 60086-4; EN IEC 60086-4; BS EN IEC 60086-4; ST/SG/AC.10/11; ST/SG/AC.10/1; J62133; UL 2054; UL 2056; UL 1642; JIS C 62133-1; J62133-2; JIS C 62133-2
EN 50360; EN 50371; EN IEC 62311; EN 62479; EN 50364; EN 50566; EN 50385; EN 50663; EN 50665; EN 62232; EN IEC 62232; IEC 62232; SPR-001; RSS-102; RSS-102.SAR.MEAS; EN 62209-1; EN 62209-2; IEEE Std.C95.1; IEEE Std. C95.3; IEEE Std. 1528:2013; IEC/IEEE 62209-1528; EN IEC/IEEE 62209-1528; AS/NZS 2772.1; AS/NZS 2772.2; BS EN IEC/IEEE 62209-1528; BS EN 62209-1; BS EN 62209-2; BS EN 50360; BS EN 50566; BS EN 50663; BS EN 62479; BS EN IEC 62311; BS EN IEC 62232; BS EN 50385; BS EN 50364; BS EN 50665; Article 14.2 of Ordinance Regulating Radio Equipment; Item 11-7, Item 11-19, and Item 11-30; Item 8; Item 11-19-2; Item 11-19-3; Item 11-29; Item 21-3; Item 47; Item 47-3; Item 47-4; and Item 54; Article 3 to Article 9; Article 17 to Article 28; Article 28-2; Article 32-10 to Article 32-25; Article 34-8-1 to Article 34-8-8; Article 34-8; and Article 34-10 of Ordinance Concerning Terminal Facilities etc; IMDA TS WBA; IMDA TS GMPCS; IMDA TS UWB; IMDA TS CT-CTS; IMDA TS SRD; IMDA TS CMT; IMDA TS CBS; IMDA RS AR; IMDA TS LMR; IMDA TS WSD
ANSI C63.4:2014; FCC MP-5 (February 1986); ANSI C63.10:2013; ANSI C63.10:2020; ANSI C63.17:2013; FCC KDB 905462 D02 (v02); ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C63.26:2015
ANSI/TIA-603-E; ANSI C63.26:2015; TIA-102.CAAA-E; IEEE Std. 1528:2013; ANSI C63.26:2015
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
9 lines
ISO/IEC 17025
Active4346.01
The scope document we hold says it is valid until 2027-11-30.
Labs with overlapping accredited scope in China
- Shenzhen Acote TechnologyShenzhen, Guangdong ProvinceA2LAShares 3 accredited test methodsANSI C63.4:2014ANSI/TIA-603-EEN IEC 62311
- CTC Laboratories, Inc.Shenzhen, GuangdongA2LAShares 2 accredited test methodsANSI C63.4:2014ANSI/TIA-603-E
- Dongguan Nore Testing Center Co.,Dongguan, GuangdongA2LAShares 2 accredited test methodsANSI C63.4:2014ANSI/TIA-603-E
- Guangdong Dongdian Testing Service Co.,Dongguan City, Guangdong ProvinceA2LAShares 2 accredited test methodsANSI C63.4:2014ANSI/TIA-603-E
- Intertek Testing Services (Shanghai FTZ) Co.,ShanghaiA2LAShares 2 accredited test methodsANSI C63.4:2014ANSI/TIA-603-E
Accreditation data refreshed from the A2LA register on .