Shenzhen CCUT Quality Technology Co.,
1F, Building 35, Changxing Technology Industrial Park, Changzhen Community, Yutang Street, Guangming District, Shenzhen, 518132, People's Republic of China, Shenzhen, China
Visit website- Accredited standards
- 71
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 71 standard numbers and the 40 official names we hold. When no standard matches, it searches the method text of every scope line.
ETSI24
ETSI EN 300 220-1
ETSI EN 300 220-2
ETSI EN 300 296
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 330Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 300 422-1
ETSI EN 300 440
ETSI EN 301 357
ETSI EN 301 489-1Exclusion
Limits written next to it
ETSI EN 301 489-1 (excluding ISO 7637-2)
ETSI EN 301 489-3
ETSI EN 301 489-5
ETSI EN 301 489-9
Show all 24
ETSI EN 301 489-17
ETSI EN 301 489-19
ETSI EN 301 489-52
ETSI EN 301 511Global System for Mobile communications (GSM); Mobile Stations (MS) equipment; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 301 893
ETSI EN 301 908-1
ETSI EN 301 908-2
ETSI EN 301 908-13
ETSI EN 302 208
ETSI EN 302 502
ETSI EN 303 413Satellite Earth Stations and Systems (SES); Global Navigation Satellite System (GNSS) receivers; Radio equipment operating in the 1 164 MHz to 1 300 MHz and 1 559 MHz to 1 610 MHz frequency bands; Harmonised Standard for access to radio spectrum
ETSI EN 303 417
IEC14
IEC 60204-1Safety of machinery - Electrical equipment of machines - Part 1: General requirements
IEC 60598-1Luminaires - Part 1: General requirements and tests+1 national
National versions in the same scope
AS/NZS 60598-1probably the same standard; matched by number only
IEC 60601-1Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 61010-1Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61547Equipment for general lighting purposes - EMC immunity requirements
IEC 62040-2Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements
IEC 62233Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure
IEC 62311Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz to 300 GHz)
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements+1 national
National versions in the same scope
AS/NZS 62368-1probably the same standard; matched by number only
IEC 62479Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
IEC 62680-1-2
IEC 62680-1-3
IEC 61000 series12
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
IEC 60335 series8
IEC 60335-1Household and similar electrical appliances - Safety - Part 1: General requirements+1 national
National versions in the same scope
AS/NZS 60335-1probably the same standard; matched by number only
IEC 60335-2-2Household and similar electrical appliances - Safety - Part 2-2: Particular requirements for vacuum cleaners and water-suction cleaning appliances+1 national
National versions in the same scope
AS/NZS 60335-2-2probably the same standard; matched by number only
IEC 60335-2-29+1 national
National versions in the same scope
AS/NZS 60335-2-29probably the same standard; matched by number only
IEC 60335-2-32+1 national
National versions in the same scope
AS/NZS 60335-2-32probably the same standard; matched by number only
IEC 60335-2-45+1 national
National versions in the same scope
AS/NZS 60335-2-45probably the same standard; matched by number only
IEC 60335-2-65+1 national
National versions in the same scope
AS/NZS 60335-2-65probably the same standard; matched by number only
IEC 60335-2-80+1 national
National versions in the same scope
AS/NZS 60335-2-80probably the same standard; matched by number only
IEC 60335-2-98+1 national
National versions in the same scope
AS/NZS 60335-2-98probably the same standard; matched by number only
CISPR6
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS/NZS CISPR 11national version with changes
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+1 national
National versions in the same scope
AS/NZS CISPR 14-1national version with changes
CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard
CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment+1 national
National versions in the same scope
AS/NZS CISPR 15national version with changes
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+1 national
National versions in the same scope
AS/NZS CISPR 32identical to it
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirementsExclusion
Limits written next to it
BS EN 55035 (excluding Annex F, H
EN4
EN 50130-4Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
EN 50385
EN 50663Generic standard for assessment of low power electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (10 MHz - 300 GHz)
EN 50665
Other standards3
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
AS/NZS 4268
FCC PART 15Radio Frequency Devices
IEC 61000-4-6; EN 61000-4-6; IEC 61000-4-8; EN 61000-4-8; IEC 61000-4-11; EN 61000-4-11; CISPR 35; EN 55035; BS EN 55035; CISPR 14-2; EN 55014-2; BS EN IEC 55014-2; IEC 61547; EN 61547; BS EN IEC 61547; EN IEC 61000-6-1; EN IEC 61000-6-3; EN IEC 61000-6-2; EN IEC 61000-6-4; BS EN IEC 61000-6-2; BS EN IEC 61000-6-4; ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-5; ETSI EN 301 489-9; ETSI EN 301 489-17; ETSI EN 301 489-19; ETSI EN 301 489-52; EN 50130-4; EN IEC 61326-1; BS EN IEC 61326-1; EN IEC 60204-1; BS EN 60204-1; EN IEC 62040-2; BS EN IEC 62040-2; EN 60601-1-2; BS EN 60601-1-2; IEC 60601-1-2; US (FCC) CFR 47 FCC Part 15C; CFR 47 FCC Part 15E; CFR 47 FCC Parts 22; CFR 47 FCC Parts 24; CFR 47 FCC Parts 25; CFR 47 FCC Parts 27; CFR 47 FCC Parts 90; CFR 47 FCC Part 74; CFR 47 FCC Part 95; Canada (ISED) RSS-GEN; RSS-130; RSS-132; RSS-133; RSS-139; RSS-195; RSS-199; RSS-210; RSS-216; RSS-247; RSS-248; RSS-310; ETSI EN 300 220-1; ETSI EN 300 220-2; ETSI EN 300 330; ETSI EN 300 440; ETSI EN 303 413; ETSI EN 303 417; ETSI EN 300 328; ETSI EN 301 893; ETSI EN 302 502; ETSI EN 301 511; ETSI EN 301 908-1; ETSI EN 301 908-2; ETSI EN 301 908-13; ETSI EN 301 357
ETSI EN 300 422-1; ETSI EN 302 208; ETSI EN 300 296; MIC Article 2-1 Item 19; MIC Article 2-1 Item 19-3; MIC Article 2-1 Item 19-3-2; ARIB STD-T66; MIC Article 2-1 Item 8; MIC Article 2-1 Item 78; AS/NZS 4268; RSS-102; RSS-102.NS.MEAS; SPR-002; IEEE C95.3; KDB 865664; KDB 447498; EN 62479; EN IEC 62311; EN 50385; EN 50663; EN 50665; AS/NZS 2772.2; BS EN 50665; EN 62233; BS EN 62233; IEC 62368-1; EN IEC 62368-1; BS EN IEC 62368-1; AS/NZS 62368-1; UL 62368-1; IEC 60335-1; EN IEC 60335-1; UL 60335-1; BS EN IEC 60335-1; AS/NZS 60335-1; IEC 60335-2-2; EN IEC 60335-2-2; UL 60335-2-2; BS EN IEC 60335-2-2; AS/NZS 60335-2-2; IEC 60335-2-29; EN IEC 60335-2-29; UL 60335-2-29; BS EN IEC 60335-2-29; AS/NZS 60335-2-29; IEC 60335-2-32; EN IEC 60335-2-32; UL 60335-2-32; BS EN IEC 60335-2-32; AS/NZS 60335-2-32; IEC 60335-2-45; EN IEC 60335-2-45; UL 60335-2-45; BS EN IEC 60335-2-45; AS/NZS 60335-2-45; IEC 60335-2-65; EN IEC 60335-2-65; UL 60335-2-65; BS EN IEC 60335-2-65; AS/NZS 60335-2-65; IEC 60335-2-80; EN IEC 60335-2-80; UL 60335-2-80; BS EN IEC 60335-2-80; AS/NZS 60335-2-80; IEC 60335-2-98; EN IEC 60335-2-98; UL 60335-2-98; BS EN IEC 60335-2-98; AS/NZS 60335-2-98; IEC 60598-1; EN IEC 60598-1; UL 60598-1; BS EN IEC 60598-1; AS/NZS 60598-1; IEC 60601-1; EN IEC 60601-1; UL 60601-1
IEC 61010-1; EN IEC 61010-1; UL 61010-1; IEC 62680-1-2; EN IEC 62680-1-2; UL 62680-1-2; IEC 62680-1-3; EN IEC 62680-1-3; UL 62680-1-3; IEC 60204-1; EN IEC 60204-1; UL 60204-1
CFR 47, FCC Part 15B; ANSI C63.4:2014; CFR 47, FCC Part 18; MP 5:1986; ICES-001; ICES-003; ICES-005; CISPR 32; EN 55032; BS EN 55032; AS/NZS CISPR 32; CISPR 14-1; EN 55014-1; BS EN IEC 55014-1; AS/NZS CISPR 14-1; CISPR 15; EN 55015; BS EN 55015; AS/NZS CISPR 15; CISPR 11; EN 55011; BS EN 55011; AS/NZS CISPR 11; IEC 61000-3-2; EN IEC 61000-3-2; BS EN IEC 61000-3-2; IEC 61000-3-3; EN IEC 61000-3-3; BS EN IEC 61000-3-3; IEC 61000-4-2; EN 61000-4-2; IEC 61000-4-4; EN 61000-4-4; IEC 61000-4-5; EN 61000-4-5
ANSI C63.4-2014; FCC MP-5 (February 1986); ANSI C63.10-2013; ANSI C63.10:2020; KDB 905462 D02 (v02); ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C63.26:2015
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-20.
Scope as published by A2LA
8 lines
ISO/IEC 17025
Active6983.01
The scope document we hold says it is valid until 2027-08-31.
Accredited scope, certificate 6983.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | CFR 47, FCC Part 15B; ANSI C63.4:2014; CFR 47, FCC Part 18; MP 5:1986; ICES-001; ICES-003; ICES-005; CISPR 32; EN 55032; BS EN 55032; AS/NZS CISPR 32; CISPR 14-1; EN 55014-1; BS EN IEC 55014-1; AS/NZS CISPR 14-1; CISPR 15; EN 55015; BS EN 55015; AS/NZS CISPR 15; CISPR 11; EN 55011; BS EN 55011; AS/NZS CISPR 11; IEC 61000-3-2; EN IEC 61000-3-2; BS EN IEC 61000-3-2; IEC 61000-3-3; EN IEC 61000-3-3; BS EN IEC 61000-3-3; IEC 61000-4-2; EN 61000-4-2; IEC 61000-4-4; EN 61000-4-4; IEC 61000-4-5; EN 61000-4-5 | - | to 40 GHz |
| 2 | IEC 61000-4-6; EN 61000-4-6; IEC 61000-4-8; EN 61000-4-8; IEC 61000-4-11; EN 61000-4-11; CISPR 35; EN 55035; BS EN 55035; CISPR 14-2; EN 55014-2; BS EN IEC 55014-2; IEC 61547; EN 61547; BS EN IEC 61547; EN IEC 61000-6-1; EN IEC 61000-6-3; EN IEC 61000-6-2; EN IEC 61000-6-4; BS EN IEC 61000-6-2; BS EN IEC 61000-6-4; ETSI EN 301 489-1; ETSI EN 301 489-3; ETSI EN 301 489-5; ETSI EN 301 489-9; ETSI EN 301 489-17; ETSI EN 301 489-19; ETSI EN 301 489-52; EN 50130-4; EN IEC 61326-1; BS EN IEC 61326-1; EN IEC 60204-1; BS EN 60204-1; EN IEC 62040-2; BS EN IEC 62040-2; EN 60601-1-2; BS EN 60601-1-2; IEC 60601-1-2; US (FCC) CFR 47 FCC Part 15C; CFR 47 FCC Part 15E; CFR 47 FCC Parts 22; CFR 47 FCC Parts 24; CFR 47 FCC Parts 25; CFR 47 FCC Parts 27; CFR 47 FCC Parts 90; CFR 47 FCC Part 74; CFR 47 FCC Part 95; Canada (ISED) RSS-GEN; RSS-130; RSS-132; RSS-133; RSS-139; RSS-195; RSS-199; RSS-210; RSS-216; RSS-247; RSS-248; RSS-310; ETSI EN 300 220-1; ETSI EN 300 220-2; ETSI EN 300 330; ETSI EN 300 440; ETSI EN 303 413; ETSI EN 303 417; ETSI EN 300 328; ETSI EN 301 893; ETSI EN 302 502; ETSI EN 301 511; ETSI EN 301 908-1; ETSI EN 301 908-2; ETSI EN 301 908-13; ETSI EN 301 357 | - | - |
| 3 | ETSI EN 300 422-1; ETSI EN 302 208; ETSI EN 300 296; MIC Article 2-1 Item 19; MIC Article 2-1 Item 19-3; MIC Article 2-1 Item 19-3-2; ARIB STD-T66; MIC Article 2-1 Item 8; MIC Article 2-1 Item 78; AS/NZS 4268; RSS-102; RSS-102.NS.MEAS; SPR-002; IEEE C95.3; KDB 865664; KDB 447498; EN 62479; EN IEC 62311; EN 50385; EN 50663; EN 50665; AS/NZS 2772.2; BS EN 50665; EN 62233; BS EN 62233; IEC 62368-1; EN IEC 62368-1; BS EN IEC 62368-1; AS/NZS 62368-1; UL 62368-1; IEC 60335-1; EN IEC 60335-1; UL 60335-1; BS EN IEC 60335-1; AS/NZS 60335-1; IEC 60335-2-2; EN IEC 60335-2-2; UL 60335-2-2; BS EN IEC 60335-2-2; AS/NZS 60335-2-2; IEC 60335-2-29; EN IEC 60335-2-29; UL 60335-2-29; BS EN IEC 60335-2-29; AS/NZS 60335-2-29; IEC 60335-2-32; EN IEC 60335-2-32; UL 60335-2-32; BS EN IEC 60335-2-32; AS/NZS 60335-2-32; IEC 60335-2-45; EN IEC 60335-2-45; UL 60335-2-45; BS EN IEC 60335-2-45; AS/NZS 60335-2-45; IEC 60335-2-65; EN IEC 60335-2-65; UL 60335-2-65; BS EN IEC 60335-2-65; AS/NZS 60335-2-65; IEC 60335-2-80; EN IEC 60335-2-80; UL 60335-2-80; BS EN IEC 60335-2-80; AS/NZS 60335-2-80; IEC 60335-2-98; EN IEC 60335-2-98; UL 60335-2-98; BS EN IEC 60335-2-98; AS/NZS 60335-2-98; IEC 60598-1; EN IEC 60598-1; UL 60598-1; BS EN IEC 60598-1; AS/NZS 60598-1; IEC 60601-1; EN IEC 60601-1; UL 60601-1 | - | - |
| 4 | IEC 61010-1; EN IEC 61010-1; UL 61010-1; IEC 62680-1-2; EN IEC 62680-1-2; UL 62680-1-2; IEC 62680-1-3; EN IEC 62680-1-3; UL 62680-1-3; IEC 60204-1; EN IEC 60204-1; UL 60204-1 | MEAS, Laboratory, Measurement and Control Equipment | - |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6983.01) 08/19/2025 Page 5 of 7
8.8H Handle strength
8.9 Wheels or casters attachment requirements
8.10 Carts, stands, and similar carriers
8.11 Mounting means for slide -rail mounted equipment
(SRME)
G.1 Switches
G.2 Relays
G.3.1-3.4 Protective devices
G.4 Connectors
G.5.3.4 Transformers using fully insulated winding wire (FIW)
G.6 Wire insulation
G7.1 Mains supply cords
G.8 Varistors
G.9 Integrated circuit (IC) current limiters
G.10 Resistors
G.11 Capacitors and RC units
G.13 Printed boards
G.14 Coatings on component terminals
G.15 Pressurized liquid filled components
G.16 IC that includes a capacitor discharge function (ICX)
L.5 Three-phase equipment
M.7 Risk of explosion from lead acid and NiCd batteries
M.8.2 Internal protection from external spark ignition source -
spark test
S.3 Flammability tests for the bottom of a fire enclosure
T.9 Glass impact test
T.10 Glass fragmentation test
Exclusion Tables
*Table #2: Clauses excluded for electrical product safety testing
Clauses Test
7 Ceiling mounted heat lamp appliances
10 Three -phase appliance
15 Accredited only for: Humidity test (External dimensions of
appliance less than
21.2 Scratch test
22.7 Stress tests
22.16 Automatic cord reel test
22.32 Rubber aging test, ceramic material strength test
22.47 Over pressure test
22.46 Software evaluation
22.48 Prevent back siphonage
22.57 UVC
22.103 Cordless blenders stresses test
23.3 Flexing occurs
27.4 Electroplated coating thickness test
29 Proof tracking index (PTI) test | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 6983.01) 08/19/2025 Page 6 of 7
Exclusion Tables
*Table #3: Clauses excluded for electrical product safety testing
Exclusion Tables
*Table #4: Clauses excluded for electrical product safety testing
Clauses Test
8 Samples larger than 100cm × 100cm × 100cm
8.5.5 Defibrillation prevention and application section
8.6.4 Impedance and current-carrying capacity
8.7 Leakage current and patient auxiliary current
8.8.4 Non-conductor insulation
8.11.3.5 Wire fixing parts
11.1 Overheating of the ME equipment
11.3 The structural requirements for the fireproof outer casing
of the ME equipment
11.6 Overflow, liquid spillage, leakage, invasion of water or
particulate matter, cleaning, disinfection, sterilization, and
the compatibility of materials used in ME equipment
13 Dangerous conditions and fault states of the ME equipment
15.3.3 Impact test
15.3.6 Samples with dimensions of 500mm x 600mm x 750mm or
larger
15.4 Components and general components of the ME equipment
15.5 The network power transformer of the ME device and the
transformer that complies with 8.5 isolation
Clauses Test
1.14 Accredited only for: Humidity test (External dimensions of
appliance less than
4.4.7 Material resistant to tracking test of rough service
luminaires
4.11.6 Electrical stresses test
4.12.5 Screwed glands test
4.13.4 Rough service luminaires
4.18 Resistance to corrosion
4.20 Vibration test
4.24 Photo biological hazards
4.26 Short-circuit protection
13.4 Resistance to tracking
14.4.5 Corrosion test | ||
| 7 | ANSI C63.4-2014; FCC MP-5 (February 1986); ANSI C63.10-2013; ANSI C63.10:2020; KDB 905462 D02 (v02); ANSI/TIA-603-E; TIA-102.CAAA-E; ANSI C63.26:2015 | - | to 40000 MHz |
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
SHENZHEN CCUT QUALITY TECHNOLOGY CO., LTD.
Shenzhen, People’s Republic of China
for technical competence in the field of
Electrical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 19th day of August 2025.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 6983.01
Valid to August 31, 2027 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Labs with overlapping accredited scope in China
- TÜV SÜD Certification and Testing (China) Co., Ltd. Guangzhou BranchGuangzhouA2LAShares 3 accredited test methodsANSI C63.4:2014IEC 61000-4-6IEC 61010-1
- Dongguan New Testing Centre Co.,DongguanA2LAShares 2 accredited test methodsANSI C63.4:2014IEC 61010-1
- Guangdong Zhonghan Testing Technology Co.,ShenzhenA2LAShares 2 accredited test methodsANSI C63.4:2014IEC 61000-4-6
- Hwa-Hsing (Dongguan) Testing Co.,GuangdongA2LAShares 2 accredited test methodsANSI C63.4:2014AS/NZS 4268
- SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen BranchShenzhen, GuangdongA2LAShares 2 accredited test methodsANSI C63.4:2014IEC 61010-1
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.