FindTestingLabs
Registers refreshed 2026-10-25.See refresh dates
China

CATARC Automotive Test Center (Guangzhou) Co.,

No.39, Xiangshan Road, Yongning Street, Zengcheng District, (Zengcheng Economic-Technological Development Zone Core Area), Guangzhou, Guangdong, People's Republic of China, Guangzhou, Guangdong, China

Visit website
A2LA 7785.01ISO/IEC 17025Register refreshed 2026-10-23

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
20
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 20 standard numbers and the 20 official names we hold. When no standard matches, it searches the method text of every scope line.

IEC 61000 series9
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-3-11Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current ≤ 75 A and subject to conditional connection
IEC 61000-3-12Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase

Certificate says EN 61000-3-12. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
ISO 11452 series4
ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
ISO 11452-8Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 8: Immunity to magnetic fields
ISO 11452-9Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 9: Portable transmitters
ISO3
ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
ISO 16750-2Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads
ISO 21498-2Electrically propelled road vehicles - Electrical specifications and tests for voltage class B systems and components - Part 2: Electrical tests for components
ISO 7637 series3
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
ISO 7637-4Road Vehicles - Electrical disturbance by conduction and coupling - Part 4: Electrical transient conduction along shielded high voltage supply lines only
Other standards1
CISPR 25Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of on-board receivers

Read from the A2LA scope document we downloaded on 2026-08-05. Register refreshed 2026-10-23.

Scope as published by A2LA

3 lines
A2LA

ISO/IEC 17025

Active

7785.01

The scope document we hold says it is valid until 2028-06-30.

View scope

Accredited scope, certificate 7785.01

LineMethodMatrixRange
1CISPR 25; UN Regulation No. 10 Annex 7, 8; ISO 11452-2; ISO 11452-4; ISO 11452-8; ISO 11452-9; ISO 10605; ISO 7637-2; ISO 7637-3; UN Regulation No. 10 Annex 10; ISO 7637-4; ISO 7637-2; ISO 7637-4; ISO 16750-2; ISO 21498-2; UN Regulation No. 10 Annex 9; UN Regulation No. 10 Annex 17Automotive EMC—component level-
2UN Regulation No. 10 Annex 18; UN Regulation No. 10 Annex 19; UN Regulation No. 10 Annex 20; UN Regulation No. 10 Annex 21; UN Regulation No. 10 Annex 22; IEC 61000-3-2; EN IEC 61000-3-2; IEC 61000-3-12; IEC 61000-3-3; EN 61000-3-3; IEC 61000-3-11; IEC 61000-4-4; EN 61000-4-4; IEC 61000-4-5; EN 61000-4-5; IEC 61000-4-6; EN IEC 61000-4-6; IEC 61000-4-8; EN 61000-4-8; IEC 61000-4-11; EN IEC 61000-4-11AC Power Lines; DC Power Lines; Network and Telecommunication Access; Power Supply Line100 to 300 A/m
3ISO/IEC 17025:2017--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

No.39, Xiangshan Road, Yongning Street, Zengcheng District, (Zengcheng Economic-Technological Development Zone Core Area), Guangzhou, Guangdong, People's Republic of China, Guangzhou, Guangdong, CN

23.11981, 113.31478

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.