Japan

KONICA MINOLTA

3-91 Daisennishi-machi, Sakai-ku, Sakai-Shi, Osaka, 590-8551, Japan, Osaka, Japan

Visit website
A2LA 3903.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
4
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 4 scope lines.

A2LA certificate 3903.01 · 4 lines

LineMethodMatrixRange
1--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3903.01) 12/15/2025 Page 1 of 3 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 KONICA MINOLTA, INC. コニカミノルタ株式会社 3-91 Daisennishi-machi Sakai-ku, Sakai-Shi Osaka, JAPAN 590-8551 Akio Nakamaru Phone: +81 72 241 3295 CALIBRATION Valid To: February 29, 2028 Certificate Number: 3903.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 4: I. Optical Qualities Parameter/Equipment Range CMC2, 5, 6(±) Comments Luminance – Measure and Measuring Equipment Coefficient (8 to 250) cd/m2 (0.1 to 0.25) sr -1 1.4 % 0.66 % Luminance coefficient standards and illuminance standards with luminance meter master bodies Spectral Radiance – Measure and Measuring Equipment (380 to 450) nm (455 to 600) nm (605 to 780) nm 6.0 % 3.9 % 4.5 % Spectroradiometer master bodies Chromaticity Coordinates (x, y) – Measure and Measuring Equipment 0.004 ≤ x ≤ 0.735 0.005 ≤ y ≤ 0.834 0.002 0.002 Luminance coefficient standards and illuminance standards with spectroradiometer master bodies
8 to 250 cd/m2
2-White Plate; Spectrophotometers
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3903.01) 12/15/2025 Page 2 of 3 Parameter/Equipment Range CMC2, 3, 5(±) Comments Spectral Reflectance of White Plate – di: 8°, de: 8° Optical Geometry Spectrophotometer (80 to 100) % 45°:0° Optical Geometry Spectrophotometer (80 to 100) % Multi-Angle Optical Geometry Spectrophotometer 45° Illumination: -15° / 15° / 25° / 45° / 75° / 110° Aspecular Viewing Angles (80 to 100) % 360 nm (370 to 390) nm (400 to 470) nm (480 to 740) nm 360 nm (370 to 390) nm (400 to 740) nm (400 to 450) nm (460 to 600) nm (610 to 700) nm 0.67 % R 0.62 % R 0.61 % R 0.41 % R 0.75 % R 0.70 % R 0.67 % R 5.6 % R 3.6 % R 4.3 % R White reflection standards with white master body Spectral Reflectance of Spectrophotometers – di: 8°, de: 8° Optical Geometry Spectrophotometer (80 to 100) % 45°:0° Optical Geometry Spectrophotometer (80 to 100) % Multi-Angle Optical Geometry Spectrophotometer 45° Illumination: -15° / 15° / 25° / 45° / 75° / 110° Aspecular Viewing Angles (80 to 100) % 360nm (370 to 390) nm (400 to 470) nm (480 to 740) nm 360 nm (370 to 390) nm (400 to 740) nm (400 to 450) nm (460 to 600) nm (610 to 700) nm 0.67 % R 0.62 % R 0.61 % R 0.42 % R 0.76 % R 0.71 % R 0.69 % R 5.6 % R 3.6 % R 4.3 % R Working white plate
80 to 100 %
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3903.01) 12/15/2025 Page 3 of 3 Parameter/Equipment Range CMC2, 3, 5(±) Comments Gloss Value of Working Gloss Plate and Gloss Plate – 60° (0 to 10) GU (10 to 20) GU (45 to 65) GU (90 to 98) GU ± 0.66 GU ± 0.88 GU ± 0.92 GU ± 0.86 GU Gloss standards with gloss master bodies Gloss Value of Glossmeter and Spectrophotometer with Gloss Function – 60° (0 to 10) GU (10 to 20) GU (45 to 65) GU (90 to 98) GU ± 0.66 GU ± 0.88 GU ± 0.96 GU ± 0.88 GU Working gloss plates _____________________________________________ 1 This laboratory offers commercial calibration services. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 In the statement of CMC, R is the reflectance. 4 This scope meets A2LA’s P112 Flexible Scope Policy. 5 In the statement of CMC, percentages are to be read as percent of reading unless otherwise noted. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter.
4ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

3-91 Daisennishi-machi, Sakai-ku, Sakai-Shi, Osaka, 590-8551, Japan, Osaka, JP

34.61988, 135.49036

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.