Registers refreshed 2026-11-08.See refresh dates
China

Industrial Internet Innovation Center (Shanghai) Co.,

Building 4, No. 766, Jingang Road, Pudong, Shanghai, China, Shanghai, 201206, People's Republic of China, Shanghai, China

A2LA 3682.01ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
37
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 37 standard numbers and the 22 official names we hold. When no standard matches, it searches the method text of every scope line.

ETSI13
ETSI TS 102 230-1
ETSI TS 136 101
ETSI TS 136 124
ETSI TS 136 133
ETSI TS 136 521-1
ETSI TS 136 521-3
ETSI TS 136 523-1
ETSI TS 136 523-2
ETSI TS 136 523-3
ETSI TS 138 521-1
ETSI TS 138 521-3
ETSI TS 138 521-4
ETSI TS 138 533
IEC 61000 series6
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test

Certificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
ISO 11452 series6
ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
ISO 11452-3Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 3: Transverse electromagnetic (TEM) cell
ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
ISO 11452-5Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 5: Stripline
ISO 11452-8Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 8: Immunity to magnetic fields
ISO 11452-9Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 9: Portable transmitters
CISPR3
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement

Certificate says EN 55011. Probably the same standard; not checked against the EN document.

CISPR 25Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of on-board receivers

Certificate says EN 55025. Probably the same standard; not checked against the EN document.

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+2 national

National versions in the same scope

AS/NZS CISPR 32identical to it

VCCI-CISPR 32probably the same standard; matched by number only

Identical and changed are as the national standards body lists them; we read that on 2026-10-06. The others are matched by number only.

Certificate says EN 55032. Probably the same standard; not checked against the EN document.

ISO 7637 series3
ISO 7637-1Road vehicles - Electrical disturbances from conduction and coupling - Part 1: Vocabulary and general considerations
ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
Other standards6
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
EN 50332-1
EN 50332-2
IEC 60950-1Information technology equipment - Safety - Part 1: General requirements+1 national

National versions in the same scope

AS/NZS 60950.1national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements+1 national

National versions in the same scope

AS/NZS 62368.1national version with changes

Identical and changed are as the national standards body lists them; we read that on 2026-10-06.

ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.

Scope as published by A2LA

7 lines
A2LA

ISO/IEC 17025

Active

3682.01

The scope document we hold says it is valid until 2027-02-28.

View scope

Accredited scope, certificate 3682.01

LineMethodMatrixRange
1ANSI C63.4:2014; CISPR 32; EN 55032; BS EN 55032; AS/NZS CISPR 32; ICES-003; VCCI-V-3; VCCI-CISPR 32:2016; CISPR 11; EN 55011; IEC 61000-3-2; EN 61000-3-2; BS EN 61000-3-2; EN IEC 61000-3-2; BS EN IEC 61000-3-2; IEC 61000-3-3; EN 61000-3-3; BS EN 61000-3-3; IEC 61000-4-2; EN 61000-4-2; BS EN 61000-4-2; GB/T 17626.3; IEC 61000-4-3; EN 61000-4-3; BS EN 61000-4-3; EN IEC 61000-4-3; BS EN IEC 61000-4-3; IEC 61000-4-4; EN 61000-4-4; BS EN 61000-4-4; IEC 61000-4-5; EN 61000-4-5; BS EN 61000-4-5-to 40 GHz
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Certificate No. 3682.01) Revised 02/18/2026 Page 2 of 6 Test Technology: Test Method(s): Conducted Immunity IEC 61000-4-6; EN 61000-4-6; BS EN 61000-4-6; EN IEC 61000-4-6; BS EN IEC 61000-4-6 Power Frequency Magnetic Field (excluding short duration mode) IEC 61000-4-8; EN 61000-4-8; BS EN 61000-4-8 Voltage Dips, Short Interruptions and Voltage Variations IEC 61000-4-11; EN 61000-4-11; BS EN 61000-4-11; EN IEC 61000-4-11; BS EN IEC 61000-4-11 Generic / Product Family / Product Specific Standards IEC 61000-6-1; EN 61000-6-1; EN IEC 61000-6-1; AS/NZS 61000.6.1; IEC 61000-6-2; EN 61000-6-2; EN IEC 61000-6-2; IEC 61000-6-3; EN IEC 61000-6-3; IEC 61000-6-4; EN IEC 61000-6-4; ETSI EN 301 489-1, -3, -7, -17, -19, -24, -25, -33, -52; ETSI EN 303 345-1; ETSI EN 303 417; ETSI EN 300 330; ETSI EN 300 386; CISPR 24; EN 55024; AS/NZS CISPR 24; CISPR 35; EN 55035; BS EN 55035; EN 60601-1-2; 3GPP TS 38.124; 3GPP TS 34.124. Radio (Transmitter and Receiver) (excluding HAC testing) Radio ANSI C63.10:2013; ANSI C63.26:2015; ANSI/TIA-603-E Canada (ISED) (up to 40 GHz) RSS-GEN, RSS-130; RSS-132; RSS-133; RSS-139; RSS-140; RSS-192; RSS-195; RSS-198; RSS-199; RSS-210; RSS-220; RSS-247; RSS-248; RSS-252 European Union (EU) ETSI EN 300 220-1, -2; ETSI EN 300 328; ETSI EN 301 893; ETSI EN 300 440; ETSI EN 301 511; ETSI EN 301 908-1, -2, -13, -25; ETSI EN 302 065-1, -2, -3, ETSI EN 303 883; ETSI TS 103 361; ETSI EN 302 502;ETSI EN 302 571; ETSI EN 303 413; ETSI EN 303 687; ETSI EN 304 220-1, -2 Australia / New Zealand AS/NZS 4268; AS/CA S042.1; AS/ACIF S042.3; AS/CA S042.4; AS/CA S042.5 Japan MIC Notice No.88 Appendix Nos. 43 & 44; MIC Notice No.88 Appendix Nos. 45 & 47; MIC Notice No.88 Annexes 29 & 79; MIC Notice No.88 Annex 86
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Certificate No. 3682.01) Revised 02/18/2026 Page 3 of 6 Test Technology: Test Method(s): RF Performance Measurements Over-the-Air Performance (OTA) CTIA Test Plan for Wireless Device Over-the-Air Performance; 3GPP TS 34.114; 3GPP TS 25.914; 3GPP TS 37.144; 3GPP TS 25.144; 3GPP TS 37.544; CTIA and Wi-Fi Alliance Test Plan for RF Performance Evaluation of Wi-Fi Mobile Converged Devices; IEEE 149 (clauses 12 and 13 only) RF Exposure/Specific Absorption Rate (SAR) IEEE Std 1528-2013; ANSI/IEEE C95.1; IEEE C95.1; ANSI/IEEE C95.3; IEEE C95.3; EN 50360; BS EN 50360; IEC 62209-1, -2; EN 62209-1, -2; BS EN 62209-1, -2; IEC 62311; EN IEC 62311; BS EN IEC 62311; IEC 62479; EN 62479; BS EN 62479; 50566; BS EN 50566; RSS-102; RSS-102.SAR.MEAS; EN IEC/IEEE 62209-1528; IEC/IEEE 62209-1528; BS EN IEC/IEEE 62209-1528; IEC 62232; EN 62232; EN IEC 62232; BS EN IEC 62232; Australian Communications Authority “Radiocommunications (Electromagnetic Radiation – Human Exposure) Standard 2003”; AS/NZS 2772.2; ARPANSA RPS S-1; Specific Absorption Rate (SAR) Estimation for Cellular Phone; MIC Announcement No. 88 Annex 79 – Head SAR Test Method; EN 50663; BS EN 50663 Radio Communications WCDMA/GSM ETSI TS 102 221; ETSI TS 102 230-1; ETSI TS 125 101; 3GPP TS 25.101; ETSI TS 125 133; 3GPP TS 25.133; ETSI TS 126 131; 3GPP TS 26.131; ETSI TS 126 132; 3GPP TS 26.132; 3GPP TS 31 101; ETSI TS 131 102; 3GPP TS 31.102; ETSI TS 131 111; 3GPP TS 31.111; 3GPP TS 31 120; ETSI TS 131 121; 3GPP TS 31.121; ETSI TS 131 124; 3GPP TS 31.124; ETSI TS 134 108; 3GPP TS 34.108; ETSI TS 134 109; 3GPP TS 34.109; ETSI TS 134 121; 3GPP TS 34.121-1; ETSI TS 134 123-1; 3GPP TS 34.123-1; ETSI TS 134 123-2; 3GPP TS 34.123-2; ETSI TS 134 123-3; 3GPP TS 34.123-3; ETSI TS 134 171; 3GPP TS 34.171; ETSI TS 151 010-1; 3GPP TS 51.010-1; ETSI TS 151 010-2; 3GPP TS 51.010-2; 3GPP TS 51.010-4; 3GPP TS 34.121-2
4ETSI TS 136 101; 3GPP TS 36.101; ETSI TS 136 124; 3GPP TS 36.124; ETSI TS 136 133; 3GPP TS 36.133; ETSI TS 136 523-1; 3GPP TS 36.523-1; ETSI TS 136 523-2; 3GPP TS 36.523-2; ETSI TS 136 523-3; 3GPP TS 36.523-3; ETSI TS 136 521-1; 3GPP TS 36.521-1; ETSI TS 136 521-3; 3GPP TS 36.521-3; 3GPP TS 36.521-2; ETSI 137 571-1, -2, -3; 3GPP TS 37.571-1; 3GPP TS 37.571-2; 3GPP TS 37.571-3; ETSI TS 102 230-1; 3GPP TS 31.121; 3GPP TS 31.124; 3GPP TS 26.131; 3GPP TS 26.132; 3GPP TR 37.901; 3GPP TS 34.229-1, -2; ETSI TS 138 521-1; 3GPP TS 38.521-1; ETSI TS 138 521-3; 3GPP TS 38.521-3; ETSI TS 138 521-4; 3GPP TS 38.521-4; ETSI TS 138 533; 3GPP TS 38.533; 3GPP TS 38.523-1; 3GPP TS 38.523-2; 3GPP TS 38.523-3; 3GPP TS 38.508-2; 3GPP TS 34.229-5; EN 50332-1; EN 50332-2; Recommendation ITU-T P.1100; Recommendation ITU-T P.1110; Recommendation ITU-T P.863--
5IEC/EN 60950-1; CSA 22.2 No.60950-1; AS/NZS 60950.1; IEC/EN 62368-1; EN IEC 62368-1; BS EN IEC 62368-1; AS/NZS 62368.1; CISPR 25; EN 55025; ISO 10605; SAE J1113-13; ISO 11452-2; ISO 11452-3; ISO 11452-4; SAE J1113-4; ISO 11452-5; ISO 11452-8; ISO 11452-9; ISO 7637-1; ISO 7637-2; SAE J1113-11; ISO 7637-3; SAE J1113-12-See scope document
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Certificate No. 3682.01) Revised 02/18/2026 Page 6 of 6 Exclusion Table *Table #1: Clauses excluded for Electrical Product Safety Testing Clause Test 2.10.3.4 MEASUREMENT OF TRANSIENT LEVELS 4.7.3.6 HIGH VOLTAGE (OVER 4 KV) FLAME TEST 5.3 SURGE TESTS 6.2.2.1 IMPULSE TEST 6.3 PROTECTION OF THE TELECOMMUNICATION WIRING SYSTEM PROTECTION FROM OVERHEATING 6.4 - ANNEX NAC OVERVOLTAGE TEST 7.4.2 SURGE TESTS Annex A TESTS FOR RESISTANCE TO HEAT AND FIRE ANNEX H, 4.3.13 IONIZING RADIATION MEASUREMENT TEST ANNEX K.2, 1.5.3 200 CYCLE THERMOSTAT TEST ANNEX K.3, 1.5.3 10,000 CYCLE THERMOSTAT ENDURANCE TEST ANNEX K.4, 1.5.3 1000 CYCLE TEMPERATURE LIMITER TEST ANNEX K.5, 1.5.3 200 CYCLE THERMAL CUT-OUT TEST
7

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Electrical Scope of Accreditation. Accredited Laboratory A2LA has accredited INDUSTRIAL INTERNET INNOVATION CENTER (SHANGHAI) CO., LTD. Shanghai, People’s Republic of China for technical competence in the field of Electrical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 20th day of May 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 3682.01 Valid to February 28, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.