Registers refreshed 2026-11-20.See refresh dates
Germany

SYNLAB MVZ Weiden

Zur Kesselschmiede 4, 92637, Weiden, Germany

DAKKS D-PL-13014-01-01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
7
DAKKS certificate
1
Site in our directory
1
DAKKS accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 7 scope lines.

DAKKS certificate D-PL-13014-01-01 · 7 lines

LineMethodMatrixRange
1DIN EN ISO/IEC 17025:2018--
2-Blut
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Anlage zur Akkreditierungsurkunde D-PL-13014-01-00 Prüfungen im Bereich: Forensik Prüfgebiete: Forensische Toxikologie, im Rahmen der Fahreignungsdiagnostik Blutalkoholuntersuchungen für forensische Zwecke, ohne Gutachten Probenahme Im Rahmen der Fahreignungsdiagnostik Flexibler Akkreditierungsbereich: Dem Prüflaboratorium ist innerhalb der mit ** gekennzeichneten Prüfbereiche, ohne dass es einer vorherigen Information und Zustimmung der DAkkS bedarf, die Modifizierung sowie Weiter- und Neuentwicklung von Prüfverfahren gestattet. Die aufgeführten Prüfverfahren sind beispielhaft. Das Prüflaboratorium verfügt über eine aktuelle Liste aller Prüfverfahren im flexiblen Akkreditierungsbereich. Die Liste ist öffentlich verfügbar auf der Webpräsenz des Prüflaboratoriums. Ausstellungsdatum: 14.01.2026 Gültig ab: 14.01.2026 Seite 2 von 7
-
3-Urin; Haare; Serum
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Anlage zur Akkreditierungsurkunde D-PL-13014-01-00 Prüfgebiet: Forensische Toxikologie, im Rahmen der Fahreignungsdiagnostik Analyt (Messgröße) Prüfgegenstand (Matrix) Prüftechnik 4-Hydroxy-Butansäure (GHB) Urin LC-MS/MS (quantitativ) Amphetamine (Amphetamin, Metamphetamin, MDA, MDMA, MDEA), Cocain (Cocain, Benzoylecgonin, Cocaethylen, Norcocain), Opiate (Morphin, 6- Monoacetylmorphin, Codein, Dihydrocodein), Benzodiazepine (Alprazolam, Bromazepam, Diazepam, Flunitrazepam, 7- Aminoflu-nitrazepam, Lorazepam, Nordiazepam, Oxazepam), Methadon und EDDP, Zolpidem, Zopiclon, Zaleplon, Opioide Analgetika (Buprenorphin, Norbuprenorphin, Tilidin, Nortilidin, Tramadol, N-Desmethyltramadol, O- Desmethyltramadol, Fentanyl, Norfentanyl, Oxycodon) Haare LC-MS/MS (quantitativ) Amphetamine (Amphetamin, Methamphetamin, MDA, MDMA; MDEA, Methylphenidat, Ritalinsäure), Cannabinoide (Cannabidiol, THC, THC-COOH, THC- OH), Cocain (Cocain, Benzoylecgonin, Cocaethylen), Opiate (6-Monocetylcodein, 6- Acetylmorphin, Codein, Dihydrocodein, Hydromorphon, Morphin, Noscapin, Papaverin), Opioide Analgetika (Buprenorphin, Norbuprenorphin, Fentanyl, Norfentanyl, Methadon, EDDP, Oxycodon, Tilidin, Nortilidin,Tramadol, N- Desmethyltramadol, O- Desmethyltramadol), LSD, Mitragynin Serum LC-MS/MS (quantitativ) Prüfart: Flüssigkeitschromatographie (LC-MS / MS, LC-MS / QTOF)** Ausstellungsdatum: 14.01.2026 Gültig ab: 14.01.2026 Seite 3 von 7
-
4-Haare; Urin; Sputum
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Anlage zur Akkreditierungsurkunde D-PL-13014-01-00 Analyt (Messgröße) Prüfgegenstand (Matrix) Prüftechnik Cannabinoide (Tetrahydrocannabinol, Cannabidiol) Haare LC-MS/MS (quantitativ) Benzodiazepine (Bromazepam, 7- Aminoflu-nitrazepam, OH- Alprazolam, OH-Midazolam, OH- Triazolam, Desalkylflurazepam, OH- Ethylflurazepam, Lorazepam, Nordiazepam, Oxazepam, Temazepam) und Zolpidem Urin LC-MS/MS (quantitativ) Drogenscreening, qualitativ: Amphetamin und Derivate (Amphetamin, Butylon, MDA, MDMA, MDPV, Metamphetamin, Methylon), Benzodiazepine (7-Aminoclonazepam, 7-Amino- flunitrazepam, 7-Amino- nitrazepam, Flurazepam, Lorazepam, Midazolam, Nitrazepam, Nordiazepam, Oxazepam, Temazepam), Cocain (Cocain, Benzoylecgonin, Cocaethylen), Opioide (6-Acetylmorphin, 6-Acetylcodein, Codein, Dihydrocodein, Morphin, Papaverin, Noscapin), Opioide Analgetika (Buprenorphin, EDDP, Fentanyl, Hydromorphon, Methadon, N- Desmethyl-tramadol, Norbupre- norphin, Norfentanyl, Nortilidin, O-Desmethyltramadol, Oxycodon, Tilidin, Tramadol), Bupropion, Citalopram, Gabapentin, Ketamin, Lidocain, LSD, Naloxon, Naltrexon, Norketamin, PCP, Pregabalin, Methylphenidat, Mitragynin, Ritalinsäure, THC, Cannabidiol, Venlafaxin, Zolpidem, Zopiclon Sputum LC-MS/MS (qualitativ) Ethylglucuronid Haare LC-MS/MS (quantitativ) Ethylglucuronid, Ethylsulfat Urin LC-MS/MS (quantitativ) Ausstellungsdatum: 14.01.2026 Gültig ab: 14.01.2026 Seite 4 von 7
-
5-Urin; EDTA-Blut; Kapillarblut; Haare; Sputum
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Anlage zur Akkreditierungsurkunde D-PL-13014-01-00 Analyt (Messgröße) Prüfgegenstand (Matrix) Prüftechnik Opioide Analgetika (Buprenorphin, Norbuprenorphin, Methadon, EDDP, Tilidin, Nortilidin, Tramadol, O-Desmethyl- und N- Desmethyltramadol, Fentanyl und Norfentanyl, Oxycodon) Urin LC-MS/MS (quantitativ) Phosphatidylethanol EDTA-Blut, Kapillarblut LC-MS/MS (quantitativ) Synthetische Cannabinoide (Metaboliten); qualitativ Urin LC-MS/QTOF (qualitativ) Synthetische Cannabinoide, qualitativ Haare LC-MS/MS (qualitativ) Synthetische Cannabinoide, qualitativ Sputum LC-MS/MS (qualitativ) THC-COOH Urin LC-MS/MS (quantitativ) Analyt (Messgröße) Prüfgegenstand (Matrix) Prüftechnik „General Unknown Screening“ Urin GC-MS (qualitativ) (R)/(S)-Amphetamin (Elvanse® / Attentin) Urin GC-MS (qualitativ) (R)/(S)-Amphetamin (Elvanse® / Attentin) Haare GC-MS/MS (quantitativ) Amphetamine (Amphetamin, Methamphetamin, MDA, MDMA, MDEA, MBDB und BDB), Cocain- Metabolit (Benzoylecgonin) und Opiate (Morphin, 6-Monoacetyl- morphin, Codein und Dihydrocodein), quantitative Bestätigungsanalyse Urin GC-MS (quantitativ) Barbiturate (Barbital, Aprobarbital, Amobarbital, Vinylbital, Pentobarbital, Secobarbital, Brallobarbital, Phenobarbital), qualitative Bestätigungsanalyse Urin GC-MS (qualitativ) THC-COOH Haare GC-MS/MS (quantitativ) Prüfart: Gaschromatographie-Massenspektrometrie (GC-MS, GC-MS / MS)** Ausstellungsdatum: 14.01.2026 Gültig ab: 14.01.2026 Seite 5 von 7
-
6-Urin; Serum, Plasma (aus Blut)
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

Anlage zur Akkreditierungsurkunde D-PL-13014-01-00 Analyt (Messgröße) Prüfgegenstand (Matrix) Prüftechnik Amphetamin, Methamphetamin, Designeramphetamine Urin ELISA (qualitativ) Barbiturate Urin CEDIA (qualitativ) Benzodiazepine Urin CEDIA (qualitativ) Cannabinoide Urin CEDIA (qualitativ) Cocain-Metabolit Urin CEDIA (qualitativ) Ethylglucuronid Urin DRI (qualitativ) LSD Urin CEDIA (qualitativ) Methadon-Metabolit Urin CEDIA (qualitativ) Opiate Urin CEDIA (qualitativ) Photometrie Analyt (Messgröße) Prüfgegenstand (Matrix) Prüftechnik Harnstoff Urin Photometrie, enzymatisch Kreatinin Urin Photometrie Spezifisches Gewicht Urin Photometrie, colorimetrisch Analyt (Messgröße) Prüfgegenstand (Matrix) Prüftechnik Alkohol Serum, Plasma (aus Blut) GC-FID Prüfart: Analyt (Messgröße) Prüfgegenstand (Matrix) Prüftechnik Ethanol Serum, Plasma (aus Blut) Enzymatisch mit ADH Prüfart: Prüfart: Immunchemische Verfahren** Photometrie: Prüfgebiet: Blutalkoholuntersuchungen für forensische Zwecke, ohne Gutachten Prüfart: Gaschromatographie (GC-FID)** Ausstellungsdatum: 14.01.2026 Gültig ab: 14.01.2026 Seite 6 von 7
-
7SOP-DROG-WEI-PROZ-1383 / 1; SOP-DROG-WEI-PROZ-577 / 1; KAW-DROG-WEI-1374 / 1; SOP-DROG-WEI-PROZ-617 / 1Kopfhaare, Körperhaare; Urin; EDTA-Blut, Trockenblut (Mitra); Sputum-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Zur Kesselschmiede 4, Weiden, 92637, DE

49.68192, 12.16181

Open in Maps

Accreditation data refreshed from the DAKKS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.