Dow Benelux
Herbert H. Dowweg, 4542 NM, TERNEUZEN, Netherlands
- Accredited standards
- 6
- RvA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the RvA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 6 standard numbers and the 6 official names we hold. When no standard matches, it searches the method text of every scope line.
EN 12619Stationary source emissions - Determination of the mass concentration of total gaseous organic carbon - Continuous flame ionisation detector method
EN 14789Stationary source emissions - Determination of volume concentration of oxygen - Standard reference method: Paramagnetism
EN 14790Stationary source emissions - Determination of the water vapour in ducts - Standard reference method
EN 14792Stationary source emissions - Determination of mass concentration of nitrogen oxides - Standard reference method: Chemiluminescence
EN 15058Stationary source emissions - Determination of the mass concentration of carbon monoxide - Standard reference method: non-dispersive infrared spectrometry
EN 15259Air quality - Measurement of stationary source emissions - Requirements for measurement sections and sites and for the measurement objective, plan and report
NEN-EN 14792; NEN-EN 14789; NEN-EN 15058; NEN-EN 12619; NEN-EN 14790
NEN-EN 15259
Read from the RvA scope document we downloaded on 2026-09-27. Register refreshed 2026-11-08.
Scope as published by RvA
2 lines
ISO/IEC 17025
ActiveL190
The scope document we hold says it is valid until 2030-08-01.
Accredited scope, certificate L190
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | NEN-EN 15259 | Geëmitteerde lucht, rook-, proces- en uitlaatgassen | - |
| 2 | NEN-EN 14792; NEN-EN 14789; NEN-EN 15058; NEN-EN 12619; NEN-EN 14790 | Geëmitteerde lucht, rook-, proces- en uitlaatgassen | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the RvA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the RvA entry linked above.