Registers refreshed 2026-11-08.See refresh dates
Sweden

AB Sydsten

Stenyxegatan 7, 213 76, Malmö, Sweden

Visit website
SWEDAC a000931-002SWEDAC A000931-002ISO/IEC 17025Register refreshed 2026-11-08

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
4
SWEDAC certificates
2
Sites in our directory
2
SWEDAC accredited scope

What this lab is accredited for

Our reading of the SWEDAC scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 4 standard numbers and the 3 official names we hold. When no standard matches, it searches the method text of every scope line.

EN 12390-2Testing hardened concrete - Part 2: Making and curing specimens for strength tests
EN 12390-3Testing hardened concrete - Part 3: Compressive strength of test specimens
EN 12390-6
EN 12390-7Testing hardened concrete - Part 7: Density of hardened concrete

Read from the scope as published by SWEDAC. Register refreshed 2026-11-08.

Scope as published by SWEDAC

2 lines
SWEDAC

ISO/IEC 17025

Active

a000931-002

View on SWEDAC

Accredited scope, certificate a000931-002

LineMethodMatrixRange
1SS-EN ISO/IEC 17025:2018 AB Sydsten Malm; SS-EN 12390-2 Provberedning Betong Ja 1 Nej SS-EN 12390-3 Tryckh; SS-EN 12390-6 Spr; SS-EN 12390-7 Densitet Betong Ja 1 Nej Typ av flexibilitet 1 : - Inf; ISO/IEC 17025:2018 AB Sydsten Malmö Ackrediteringsnummer 1935 Laboratoriet i Fosie A000931-002 Fysiska egenskaper Väg- och byggnadsmaterial Metod Parameter Provtyp Flex Typ av flex Fält SS 137244 Frostresistens Betong Ja 1 Nej SS 137245 Frostresistens Betong Ja 1 Nej SS-EN 12390-2 Provberedning Betong Ja 1 Nej SS-EN 12390-3 Tryckhållfasthet Betong Ja 1 Nej SS-EN 12390-6 Spräckhållfasthet Betong Ja 1 Nej SS-EN 12390-7 Densitet Betong Ja 1 Nej Typ av flexibilitet 1Betong-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

SWEDAC

ISO/IEC 17025

Active

A000931-002

View on SWEDAC

Accredited scope, certificate A000931-002

LineMethodMatrixRange
1SS-EN ISO/IEC 17025:2018; SS 137244; SS 137245; SS-EN 12390-2; SS-EN 12390-3; SS-EN 12390-6; SS-EN 12390-7Betong-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Stenyxegatan 7, Malmö, 213 76, SE

55.55446, 13.03837

Open in Maps

Other Locations

1 other site in this organization

Accreditation data refreshed from the SWEDAC register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the SWEDAC entry linked above.