FindTestingLabs
Registers refreshed 2026-10-18.See refresh dates
Netherlands

Normec Dumea

Industrieweg 16, 8131 VZ, WIJHE, Netherlands

RvA|L610ISO/IEC 17025Register refreshed 2026-10-18
Certificates
1
Scope items
5
Standards
5
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Normec Dumea?

Claim this profile to keep it accurate.

Register record

RvARefreshed
L610Active

Accredited standards

5

Our reading of the RvA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

ISO 6579-1Microbiology of the food chain - Horizontal method for the detection, enumeration and serotyping of Salmonella - Part 1: Detection of Salmonella spp.
As written on the certificate · Line 5 (RvA L610)

NEN-EN-ISO 6579-1

ISO 10523Water quality - Determination of pH
As written on the certificate · Line 2 (RvA L610)

NEN-EN-ISO 11731; NEN-EN-ISO 19458; Uitvoeringsregeling Meststoffenwet; NEN-EN-ISO 10523; NEN 6414

ISO 11731Water quality - Enumeration of LegionellaCertificate says EN ISO 11731 2019-03 UBA Empfehlung 18. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 2 (RvA L610)

NEN-EN-ISO 11731; NEN-EN-ISO 19458; Uitvoeringsregeling Meststoffenwet; NEN-EN-ISO 10523; NEN 6414

ISO 15681-2Water quality - Determination of orthophosphate and total phosphorus contents by flow analysis (FIA and CFA) - Part 2: Method by continuous flow analysis (CFA)
As written on the certificate · Line 3 (RvA L610)

EN ISO/IEC 17025:2017; NEN 5793; NEN-EN-ISO 15681-2; NEN 5709:2006; NEN 5704; NEN 7430; NEN 7431; NEN 7433; NEN 7434; NEN 7435

ISO 19458Water quality - Sampling for microbiological analysis
As written on the certificate · Line 1 (RvA L610)

NEN-EN-ISO 19458

As written on the certificate · Line 2 (RvA L610)

NEN-EN-ISO 11731; NEN-EN-ISO 19458; Uitvoeringsregeling Meststoffenwet; NEN-EN-ISO 10523; NEN 6414

Scope as published by RvA

5 lines
RvA

ISO/IEC 17025

Active

L610

The scope document we hold says it is valid until 2027-08-01.

View scope

Accredited scope, certificate L610

LineDisciplineMethodMatrixRange
1environmentalNEN-EN-ISO 19458Drinkwater, grondwater, zwembadwater-
2-NEN-EN-ISO 11731; NEN-EN-ISO 19458; Uitvoeringsregeling Meststoffenwet; NEN-EN-ISO 10523; NEN 6414Proceswater; koeltorenwater; Oppervlaktewater; afvalwater; Bodem (grond); Dikke fractie: vaste mest, bestaande uit koek na mestscheiding met mestcode 13 en/of 43 en mengsels waarin koek na mestscheiding met mestcode 13 of 43 is opgenomen; Drinkwater; grondwater; zwembadwater-
3chemicalEN ISO/IEC 17025:2017; NEN 5793; NEN-EN-ISO 15681-2; NEN 5709:2006; NEN 5704; NEN 7430; NEN 7431; NEN 7433; NEN 7434; NEN 7435Zwembadwater; Drijfmest, mineralen-concentraat van drijfmest en vaste mest; Ruwvoeders; Bodem (grond)-
4chemical-Ruwvoeders, Drinkwater, grondwater, zwembadwater, Drijfmest, vaste mest en spuiwater, Proceswater, koeltorenwater-
5biologicalNEN-EN-ISO 6579-1Legionella isolaten uit water-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Industrieweg 16, WIJHE, 8131 VZ, NL

52.38414, 6.13602

Open in Maps

Accreditation data refreshed from the RvA register on .