Normec Dumea
Industrieweg 16, 8131 VZ, WIJHE, Netherlands
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at Normec Dumea?
Claim this profile to keep it accurate.
Register record
- RvARefreshed
- L610Active
Accredited standards
5Our reading of the RvA scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
ISO 6579-1Microbiology of the food chain - Horizontal method for the detection, enumeration and serotyping of Salmonella - Part 1: Detection of Salmonella spp.
NEN-EN-ISO 6579-1
ISO 10523Water quality - Determination of pH
NEN-EN-ISO 11731; NEN-EN-ISO 19458; Uitvoeringsregeling Meststoffenwet; NEN-EN-ISO 10523; NEN 6414
ISO 11731Water quality - Enumeration of LegionellaCertificate says EN ISO 11731 2019-03 UBA Empfehlung 18. Probably the same standard; not checked against the EN document.
NEN-EN-ISO 11731; NEN-EN-ISO 19458; Uitvoeringsregeling Meststoffenwet; NEN-EN-ISO 10523; NEN 6414
ISO 15681-2Water quality - Determination of orthophosphate and total phosphorus contents by flow analysis (FIA and CFA) - Part 2: Method by continuous flow analysis (CFA)
EN ISO/IEC 17025:2017; NEN 5793; NEN-EN-ISO 15681-2; NEN 5709:2006; NEN 5704; NEN 7430; NEN 7431; NEN 7433; NEN 7434; NEN 7435
ISO 19458Water quality - Sampling for microbiological analysis
NEN-EN-ISO 19458
NEN-EN-ISO 11731; NEN-EN-ISO 19458; Uitvoeringsregeling Meststoffenwet; NEN-EN-ISO 10523; NEN 6414
Scope as published by RvA
5 lines
ISO/IEC 17025
ActiveL610
The scope document we hold says it is valid until 2027-08-01.
Accredited scope, certificate L610
| Line | Discipline | Method | Matrix | Range |
|---|---|---|---|---|
| 1 | environmental | NEN-EN-ISO 19458 | Drinkwater, grondwater, zwembadwater | - |
| 2 | - | NEN-EN-ISO 11731; NEN-EN-ISO 19458; Uitvoeringsregeling Meststoffenwet; NEN-EN-ISO 10523; NEN 6414 | Proceswater; koeltorenwater; Oppervlaktewater; afvalwater; Bodem (grond); Dikke fractie: vaste mest, bestaande uit koek na mestscheiding met mestcode 13 en/of 43 en mengsels waarin koek na mestscheiding met mestcode 13 of 43 is opgenomen; Drinkwater; grondwater; zwembadwater | - |
| 3 | chemical | EN ISO/IEC 17025:2017; NEN 5793; NEN-EN-ISO 15681-2; NEN 5709:2006; NEN 5704; NEN 7430; NEN 7431; NEN 7433; NEN 7434; NEN 7435 | Zwembadwater; Drijfmest, mineralen-concentraat van drijfmest en vaste mest; Ruwvoeders; Bodem (grond) | - |
| 4 | chemical | - | Ruwvoeders, Drinkwater, grondwater, zwembadwater, Drijfmest, vaste mest en spuiwater, Proceswater, koeltorenwater | - |
| 5 | biological | NEN-EN-ISO 6579-1 | Legionella isolaten uit water | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the RvA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the RvA entry linked above.