Capstone Calibration
7016 & 7024 Baker Blvd, 76118, Richland Hills, TX, United States
Visit website- Accredited standards
- 1
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 1 standard number and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.
ASTM E18Standard Test Methods for Rockwell Hardness of Metallic Materials
ASTM E18
Read from the A2LA scope document we downloaded on 2025-12-02. Register refreshed 2026-11-20.
Scope as published by A2LA
6 lines
ISO/IEC 17025
Active1593.01
The scope document we hold says it was valid until 2026-01-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2025-12-02. Check the A2LA register for the current scope.
Accredited scope, certificate 1593.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2005; ison to master square Parallelism Up to 36; IEC 17025; ANSI/NCSL Z540-1-1994 CAPSTONE CALIBRATION 7016 | Electronic | See scope document |
| 2 | - | ElectronicShow page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1593.01) 01/08/2024 Page 2 of 5
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Straightness
3
Up to 72 in
(20 + 0.77L) µin
Autocollimator
Autocollimators
Up to 10 arc-min
0.66 arc-sec
Gage blocks & sine bar
Calipers3
Up to 36 in
(37 to 80) in
(170 + 0.6R) µin
(390 + 0.6R) µin
Gage blocks
Micrometers
3
Up to 24 in
(83 + 0.6R) µin
(180 + 0.6R) µin
Gage blocks
Digital & Dial
Indicators
3 – Up to 6 in
0.000 010 in resolution
0.000 020 in resolution
0.000 050 in resolution
0.000 100 in resolution
0.000 500 in resolution
0.001 000 in resolution
12 µin
20 µin
46 µin
92 µin
440 µin
810 µin
Gage blocks, ULM
Height Gages
3
High Resolution
Up to 48 in
Up to 48 in
(310 + 0.6R) µin
(130 + 0.6R) µin
Gage blocks
Length Standards
Up to 60 in
(20 + 3.7L) µin
Gage blocks, electronic indicator
& amplifier, ULM
Wires/Pins / Plug
Gages & Outside
Cylindrical Diameter
Up to 3 in
17 µin
ULM, gage blocks
Plain Rings & Inside
Cylindrical Diameter
Up to 10 in
24 µin
Ring gage comparator,
gage blocks
Thread Plugs –
Pitch Diameter
Major Diameter
Up to 10 in
140 µin
17 µin
3 wire method
ULM, gage blocks | to 72 in |
| 3 | ASTM E18 | - | to 12 in |
| 4 | ASTM E18 | Test blocks | 10 to 250 lbfꞏin to lbfꞏft |
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 1593.01) 01/08/2024 Page 5 of 5
3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties
achievable on a customer's site can normally be expected to be larger than the CMC found on the A2LA
Scope. Allowance must be made for aspects such as the environment at the place of calibration and for
other possible adverse effects such as those caused by transportation of the calibration equipment. The
usual allowance for the actual uncertainty introduced by the item being calibrated, (e.g. resolution) must
also be considered and this, on its own, could result in the actual measurement uncertainty achievable on
a customer’s site being larger than the CMC.
4 In the statement of best measurement uncertainty, DL is the numerical value of the nominal length in
inches of the diagonal, L is the numerical value of the nominal length, and R is the numerical value
of the resolution of the device in microinches.
5 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 6 | ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025; ANSI/NCSL Z540-1-1994 and R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Applied Technical Services, LLC.Bartlett, TN · ~729 kmA2LAShares 2 accredited methods and materialsASTM E18Electronic
- Accu-ChekCorydon, IN · ~1,170 kmA2LAShares 2 accredited methods and materialsASTM E18Electronic
- Applied Technical ServicesGreer, SC · ~1,404 kmA2LAShares 2 accredited methods and materialsASTM E18Electronic
- Applied Technical Services , LLC.Sanford, FL · ~1,587 kmA2LAShares 2 accredited methods and materialsASTM E18Electronic
- Applied Technical ServicesSacramento, CA · ~2,275 kmA2LAShares 2 accredited methods and materialsASTM E18Electronic
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.