Caterpillar Inc., Integrated Components & Solutions Division, Advanced Materials Technology, TC-K Metallurgical

14009 Old Galena Rd, Bldg. TC-K Met-lab, 61534, Chillicothe, IL, United States

Visit website
A2LA 3389.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
9
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 9 standard numbers and the 7 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM E3Standard Guide for Preparation of Metallographic Specimens
ASTM E8Standard Test Methods for Tension Testing of Metallic Materials
ASTM E10Standard Test Method for Brinell Hardness of Metallic Materials
ASTM E114
ASTM E340Standard Practice for Macroetching Metals and Alloys
ASTM E384Standard Test Method for Microindentation Hardness of Materials
ASTM E415Standard Test Method for Analysis of Carbon and Low-Alloy Steel by Spark Atomic Emission Spectrometry
ASTM E1019Standard Test Methods for Determination of Carbon, Sulfur, Nitrogen, and Oxygen in Steel, Iron, Nickel, and Cobalt Alloys by Combustion and Inert Gas Fusion Techniques
ASTM E1304

Read from the A2LA scope document we downloaded on 2025-12-02. Register refreshed 2026-11-20.

Scope as published by A2LA

3 lines
A2LA

ISO/IEC 17025

Active

3389.01

The scope document we hold says it is valid until 2027-07-31.

View scope

Accredited scope, certificate 3389.01

LineMethodMatrixRange
1ASTM E10; ASTM E384; ASTM E8; ASTM E3; ASTM E340Metal-
2ASTM E1019; ASTM E1304; ASTM E415; ASTM E114Metal-
3ISO/IEC 17025:2017; ISO-ILAC-IAF Communiqué dated April 2017; IEC 17025--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.