NEMKO
Reetzstraße 58, 76327, Pfinztal, Germany
Visit website- Accredited standards
- 219
- DAKKS certificates
- 5
- Site in our directory
- 1
What this lab is accredited for
Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 219 standard numbers and the 74 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 60335 series50
IEC 60335-1Household and similar electrical appliances - Safety - Part 1: General requirements
IEC 60335-2-3Household and similar electrical appliances - Safety - Part 2-3: Particular requirements for electric irons
IEC 60335-2-6
IEC 60335-2-8Household and similar electrical appliances - Safety - Part 2-8: Particular requirements for shavers, hair clippers and similar appliances
IEC 60335-2-9Household and similar electrical appliances - Safety - Part 2-9: Particular requirements for grills, toasters and similar portable cooking appliances
IEC 60335-2-12Household and similar electrical appliances - Safety - Part 2-12: Particular requirements for warming plates and similar appliances
IEC 60335-2-13Household and similar electrical appliances - Safety - Part 2-13: Particular requirements for deep fat fryers, frying pans and similar appliances
IEC 60335-2-14
IEC 60335-2-15
IEC 60335-2-21
IEC 60335-2-23
IEC 60335-2-24
Show all 50
IEC 60335-2-25
IEC 60335-2-26
IEC 60335-2-27
IEC 60335-2-29
IEC 60335-2-30
IEC 60335-2-31
IEC 60335-2-32
IEC 60335-2-36
IEC 60335-2-37
IEC 60335-2-38
IEC 60335-2-39
IEC 60335-2-40
IEC 60335-2-41
IEC 60335-2-42
IEC 60335-2-43
IEC 60335-2-45
IEC 60335-2-47
IEC 60335-2-48
IEC 60335-2-49
IEC 60335-2-50
IEC 60335-2-52
IEC 60335-2-54
IEC 60335-2-55
IEC 60335-2-59
IEC 60335-2-60
IEC 60335-2-64
IEC 60335-2-65
IEC 60335-2-71
IEC 60335-2-78
IEC 60335-2-79
IEC 60335-2-80
IEC 60335-2-82
IEC 60335-2-85
IEC 60335-2-89
IEC 60335-2-90
IEC 60335-2-98
IEC 60335-2-99
IEC 60335-2-101
IEC 61000 series25
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
IEC 61000-3-11Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current ≤ 75 A and subject to conditional connection
IEC 61000-3-12Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-9Electromagnetic compatibility (EMC) - Part 4-9: Testing and measurement techniques - Impulse magnetic field immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
Show all 25
IEC 61000-4-13Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics including mains signalling at a.c. power port, low frequency immunity tests
IEC 61000-4-16
IEC 61000-4-17
IEC 61000-4-20
IEC 61000-4-28
IEC 61000-4-29Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests
IEC 61000-4-39Electromagnetic compatibility (EMC) - Part 4-39: Testing and measurement techniques - Radiated fields in close proximity - Immunity test
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
IEC 61000-6-7
IEC 61000-6-8
ETSI18
ETSI EN 300 220-1
ETSI EN 300 220-2
ETSI EN 300 328Wideband transmission systems; Data transmission equipment operating in the 2,4 GHz band; Harmonised Standard for access to radio spectrum
ETSI EN 300 330Short Range Devices (SRD); Radio equipment in the frequency range 9 kHz to 25 MHz and inductive loop systems in the frequency range 9 kHz to 30 MHz; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 300 440
ETSI EN 301 489-1
ETSI EN 301 489-3
ETSI EN 301 489-17
ETSI EN 301 489-52
ETSI EN 301 511Global System for Mobile communications (GSM); Mobile Stations (MS) equipment; Harmonised Standard covering the essential requirements of article 3.2 of Directive 2014/53/EU
ETSI EN 301 893
ETSI EN 301 908-1
Show all 18
ETSI EN 302 208
ETSI EN 302 291-1
ETSI EN 302 291-2
ETSI EN 303 413Satellite Earth Stations and Systems (SES); Global Navigation Satellite System (GNSS) receivers; Radio equipment operating in the 1 164 MHz to 1 300 MHz and 1 559 MHz to 1 610 MHz frequency bands; Harmonised Standard for access to radio spectrum
ETSI EN 303 446-1
ETSI EN 303 446-2
IEC 60598 series17
IEC 60598-1Luminaires - Part 1: General requirements and tests
IEC 60598-2-1
IEC 60598-2-2
IEC 60598-2-3
IEC 60598-2-4
IEC 60598-2-5
IEC 60598-2-8
IEC 60598-2-10
IEC 60598-2-11
IEC 60598-2-12
IEC 60598-2-18
IEC 60598-2-19
Show all 17
IEC 60598-2-20
IEC 60598-2-21
IEC 60598-2-22
IEC 60598-2-24
IEC 60598-2-25
IEC16
IEC 60034-1
IEC 60669-2-1
IEC 60945Maritime navigation and radiocommunication equipment and systems - General requirements - Methods of testing and required test results
IEC 60950-1Information technology equipment - Safety - Part 1: General requirements
IEC 60968
IEC 61131-2
IEC 61204-3
IEC 61547Equipment for general lighting purposes - EMC immunity requirements
IEC 61800-3Adjustable speed electrical power drive systems - Part 3: EMC requirements and specific test methods for PDS and machine tools
IEC 62031
IEC 62040-1
IEC 62040-2Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements
IEC 62061
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements
IEC 62560
IEC 62920
IEC 61010 series16
IEC 61010-1Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
IEC 61010-2-010
IEC 61010-2-011
IEC 61010-2-012
IEC 61010-2-020
IEC 61010-2-030
IEC 61010-2-032
IEC 61010-2-033
IEC 61010-2-034
IEC 61010-2-040Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-040: Particular requirements for sterilizers and washer-disinfectors used to treat medical materials
IEC 61010-2-051
IEC 61010-2-081
IEC 61010-2-101Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-101: Particular requirements for in vitro diagnostic (IVD) medical equipment
IEC 61010-2-201
IEC 61010-031
IEC 61010-31
EN13
EN 298
EN 12405-1
EN 13611
EN 14236
Limits written next to it
EMV DIN EN 14236:2008 -06 Ultraschall -Haushaltsgaszähler Nur EMV
EMV EN 14236:2007 Ultrasonic domestic gas meters Only EMC
EMV EN 14236:2018 Ultrasonic domestic gas meters Only EMC
EN 16314Some clauses
Limits written next to it
EMV EN 16314:2013 Gas meters - Additional functionalities Only clauses 4.12
EN 45501
EN 50121-3-2Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
EN 50121-4Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus
EN 50130-4Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
EN 50148
EN 50270
EN 50293
EN 50370-2
IEC 60730 series10
IEC 60730-1Automatic electrical controls - Part 1: General requirements
IEC 60730-2-5
IEC 60730-2-6
IEC 60730-2-7
IEC 60730-2-8
IEC 60730-2-9
IEC 60730-2-11
IEC 60730-2-13
IEC 60730-2-14
IEC 60730-2-15
IEC 61326 series9
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61326-2-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications
IEC 61326-2-2Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems
IEC 61326-2-3Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning
IEC 61326-2-4
IEC 61326-2-5
IEC 61326-2-6Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical electrical equipment
IEC 61326-3-1
IEC 61326-3-2
ISO 26262 series9
ISO 26262-2Road vehicles - Functional safety - Part 2: Management of functional safety
ISO 26262-3Road vehicles - Functional safety - Part 3: Concept phase
ISO 26262-4Road vehicles - Functional safety - Part 4: Product development at the system level
ISO 26262-5Road vehicles - Functional safety - Part 5: Product development at the hardware level
ISO 26262-6Road vehicles - Functional safety - Part 6: Product development at the software level
ISO 26262-7Road vehicles - Functional safety - Part 7: Production, operation, service and decommissioning
ISO 26262-8Road vehicles - Functional safety - Part 8: Supporting processes
ISO 26262-9Road vehicles - Functional safety - Part 9: Automotive safety integrity level (ASIL)-oriented and safety-oriented analyses
ISO 26262-12Road vehicles - Functional safety - Part 12: Adaptation of ISO 26262 for motorcycles
CISPR8
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard
CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurement
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements
IEC 61558 series7
IEC 61558-1
IEC 61558-2-1
IEC 61558-2-2
IEC 61558-2-4
IEC 61558-2-5
IEC 61558-2-6
IEC 61558-2-16
IEC 60601 series5
IEC 60601-1Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
IEC 60601-1-1
IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 60601-2-10
IEC 60601-2-18
ISO 25119 series4
ISO 25119-1Tractors and machinery for agriculture and forestry - Safety-related parts of control systems - Part 1: General principles for design and development
ISO 25119-2Tractors and machinery for agriculture and forestry - Safety-related parts of control systems - Part 2: Concept phase
ISO 25119-3Tractors and machinery for agriculture and forestry - Safety-related parts of control systems - Part 3: Series development, hardware and software
ISO 25119-4Tractors and machinery for agriculture and forestry - Safety-related parts of control systems - Part 4: Production, operation, modification and supporting processes
IEC 60947 series3
IEC 60947-1
IEC 60947-2
IEC 60947-5-1
IEC 61347 series3
IEC 61347-1
IEC 61347-2-11
IEC 61347-2-13
IEC 61508 series3
IEC 61508-1
IEC 61508-2
IEC 61508-3
ISO3
ISO 10218-1Robotics - Safety requirements - Part 1: Industrial robots
ISO 13482Robots and robotic devices - Safety requirements for personal care robots
ISO 13849-1Safety of machinery - Safety-related parts of control systems - Part 1: General principles for design
DIN EN 60335 -1:2024 -07; IEC 60335 -1:2010 + COR1:2010 + COR2:2011 + A1:2013 + A1:2013/COR1:2014 + A2:2016 + A2:2016/COR1:2016; DIN EN 60669 -2-1:2010 -03 + A12:2010-09; IEC 60669 -2-1:2002 + A1:2008; DIN EN 60730 -1:2021 -06; IEC 60730 -1:2013 + COR1:2014 + A1:2015
DIN EN 60335-1:2020-08; DIN EN 60335-2-3:2021-05; DIN EN 60335-2-6:2021-02; DIN EN 60335-2-8:2016-08; DIN EN 60335-2-9:2011-10
DIN EN 60335-2-12:2021-01; DIN EN 60335-2-13:2020-04; DIN EN 60335-2-14:2017-12; DIN EN 60335-2-15:2022-05; DIN EN 60335-2-21:2023-02; DIN EN 60335-2-23:2015-06
DIN EN 60335-2-24:2019-11 + A11:2021-11; IEC 60335-2-24:2010 + A1:2012, modifiziert + A2:2017; EN 60335-2-24:2010 + A1:2019 + A2:2019; EN 60335-2-24:2010/A11:2020; DIN EN 60335-2-25:2016-09; IEC 60335-2-25:2010, modifiziert + A1:2014 + A2:2015; EN 60335-2-25:2012 + A1:2015 + A2:2016; DIN EN 60335-2-26:2009-01; IEC 60335-2-26:2002 + A1:2008; EN 60335-2-26:2003 + A1:2008; DIN EN 60335-2-27:2021-08; IEC 60335-2-27:2009, modifiziert + A1:2012, modifiziert + A2:2015, modifiziert + A2:2015/COR1:2015 + A2:2015/COR2:2016; EN 60335-2-27:2013 + A1:2020 + A2:2020
DIN EN 60335-2-29:2019-06; DIN EN 60335-2-30:2021-05; DIN EN 60335-2-31:2015-06; DIN EN IEC 60335-2-32:2022-02; DIN EN 60335-2-36:2012-12
DIN EN 60335-2-37:2017-11; IEC 60335-2-37:2002 + A1:2008; EN 60335-2-37:2002 + Cor.:2007 + A1:2008 + A11:2012 + A12:2016; DIN EN 60335-2-38:2008-12; IEC 60335-2-38:2002 + A1:2008; EN 60335-2-38:2003 + Corrigendum 2007 + A1:2008; DIN EN 60335-2-39:2009-04; IEC 60335-2-39:2002 + A1:2004 + A2:2008; EN 60335-2-39:2003 + A1:2004 + Corrigendum:2007 + A2:2008; DIN EN 60335-2-40:2014-01; IEC 60335-2-40:2002, modifiziert + A1:2005, modifiziert + A2:2005, modifiziert + Cor. 1:2006; EN 60335-2-40:2003 + A11:2004 + A12:2005 + A1:2006 + Cor.:2006 + A2:2009 + Cor.:2010 + A13:2012 + A13:2012/AC:2013
DIN EN 60335-2-41:2010-11; DIN EN 60335-2-42:2012-12; DIN EN IEC 60335-2-43:2023-02; DIN EN 60335-2-45:2012-08; DIN EN 60335-2-47:2020-10
DIN EN 60335-2-48:2020-10; DIN EN 60335-2-49:2020-12; DIN EN 60335-2-50:2008-11; DIN EN 60335-2-52:2020-07
DIN EN 60335-2-54:2017-11; DIN EN 60335-2-55:2019-05; DIN EN 60335-2-59:2019-11; DIN EN 60335-2-60:2010-11
DIN EN 60335-2-64; DIN EN 60335-2-65; DIN EN IEC 60335-2-71; DIN EN 60335-2-78; DIN EN 60335-2-79
DIN EN 60335-2-80:2009-10; DIN EN IEC 60335-2-82:2023-03; DIN EN 60335-2-85:2020-11; DIN EN 60335-2-89:2018-10; DIN EN IEC 60335-2-90:2023-03
DIN EN 60335-2-98:2020-05; DIN EN 60335-2-99:2019-12; DIN EN 60335-2-101:2017-08; DIN EN 60730-1:2021-06; DIN EN 60730-2-5:2020-01
DIN EN 61000-3-2:2010-03; EC 61000-3-2:2005 + A1:2008 + A2:2009; IEC 61000-3-2:2005 + A1:2008 + A2:2009; DIN EN IEC 61000-3-2:2019-12; IEC 61000-3-2:2018; DIN EN 61000-3-3:2014-03; IEC 61000-3-3:2013
DIN EN 61000-3-3:2023-02; IEC 61000-3-3:2013 + A1:2017 + A2:2021; DIN EN 61000-3-11:2001-04; IEC 61000-3-11:2000
DIN EN 61000-3-11:2021-03; IEC 61000-3-11:2017; DIN EN 61000-3-12:2012-06; IEC 61000-3-12:2011; DIN EN 61131-2:2008-04; IEC 61131-2:2007
DIN EN 61000-4-2:2009-12; IEC 61000-4-2:2009; DIN EN 61000-4-3:2011-04; DIN EN IEC 61000-4-3:2021-11; IEC 61000-4-3:2020; IEC 61000-4-3:2006 + A1:2007 + A2:2010
DIN EN 61000-4-4; IEC 61000-4-4; DIN EN 61000-4-5; IEC 61000-4-5; DIN EN 61000-4-5; IEC 61000-4-5; DIN EN 61000-4-6; IEC 61000-4-6
DIN EN 61000-4-6:2014-08; IEC 61000-4-6:2013; DIN EN 61000-4-8:2010-11; IEC 61000-4-8:2009; DIN EN 61000-4-9:2017-05; IEC 61000-4-9:2016; DIN EN 61000-4-11:2005-02; IEC 61000-4-11:2004
IEC 61000-4-11:2004; DIN EN 61000-4-11:20 21 -10; IEC 61000-4-11:2020 + COR1:2020 + COR2:2022; DIN EN 61000-4-13:2010 -04; IEC 61000-4-13:2002 + A1:2009
DIN EN 61000-4-13; IEC 61000-4-13; DIN EN 61000-4-16; IEC 61000-4-16
IEC 61000 -4-16 :2015; DIN EN 61000 -4-17:2005 -04; IEC 61000 -4-17:1999 + A1:2001; DIN EN 61000 -4-17:2005 -04/A2:2009-11; IEC 61000 -4-17:1999/A2:2008; DIN EN 61000 -4-20:2011 -07; IEC 61000 -4-20:2010
DIN EN 61000-4-28; IEC 61000-4-28; DIN EN 61000-4-29; IEC 61000-4-29; DIN EN 61000-4-39; IEC 61000-4-39
DIN EN 61000 -6-1:2007 -10; IEC 61000 -6-1:2005; DIN EN IEC 61000 -6-1:2019 -11; IEC 61000 -6-1:2016; DIN EN 61000 -6-2:2006 -03; IEC 61000 -6-2:2005; DIN EN IEC 61000 -6-2:2019 -11; IEC 61000 -6-2:2016
DIN EN 61000-6-3:2011-09; IEC 61000-6-3:2006 + A1:2010; DIN EN IEC 61000-6-3:2022-06; IEC 61000-6-3:2020; DIN EN 61000-6-4:2011-09; IEC 61000-6-4:2006 + A1:2010; DIN EN IEC 61000-6-4:2020-09; IEC 61000-6-4:2018
DIN EN 61000-6-7:2015-12; IEC 61000-6-7:2014; DIN EN IEC 61000-6-8:2022-02; IEC 61000-6-8:2020; DIN EN 298:2012-11; EN 298:2012; DIN EN 12405-1:2011-04; EN 12405-1:2005 + A2:2010; DIN EN 12405-1:2022-02
ETSI EN 300 220-1 V3.1.1:2017-02; ETSI EN 300 220-2 V3.2.1:2018-06; ETSI EN 300 328 V2.2.2:2019-07; ETSI EN 300 330 V2.1.1:2017-02; ETSI EN 300 440 V2.2.1:2018-07; ETSI EN 301 489-1 V2.2.3:2019-11; ETSI EN 301 489-3 V2.3.2:2023-01; ETSI EN 301 489-17 V3.2.4:2020-09
ETSI EN 301 489-52 V1.2.1:2021-11; ETSI EN 301 511 V12.5.1:2017-03; ETSI EN 301 893 V2.1.1:2017-05; ETSI EN 301 908-1 V15.2.1:2023-01; ETSI EN 302 208 V3.3.1 (2020-08); ETSI EN 302 291-1 V1.1.1:2005-07; ETSI EN 302 291-2 V1.1.1:2005-07
ETSI EN 303 413 V1.2.1 (2021-04); ETSI EN 303 446-1 V1.2.1:2019-10; ETSI EN 303 446-2 V1.2.1:2019-10
DIN EN IEC 60730-2-14:2023-03; DIN EN IEC 60730-2-15:2020-02; DIN EN IEC 60598-1:2023-01 + A11:2023-01; DIN EN IEC 60598-2-1:2021-11; DIN EN 60598-2-2:2012-10; DIN EN 60598-2-3:2011-12
DIN EN 60598-2-4:2018-11; IEC 60598-2-4:2017; EN 60598-2-4:2018; DIN EN 60598-2-5:2016-09; IEC 60598-2-5:2015; EN 60598-2-5:2015; DIN EN 60598-2-8:2014-03; IEC 60598-2-8:2013; EN 60598-2-8:2013; DIN EN 60598-2-10:2004-03; IEC 60598-2-10:2003; EN 60598-2-10:2003; DIN EN 60598-2-11:2014-04; IEC 60598-2-11:2013; EN 60598-2-11:2013; DIN EN 60598-2-12:2014-03; IEC 60598-2-12:2013; EN 60598-2-12:2013; DIN EN IEC 60598-2-18:2023-04; IEC 60598-2-18:2022; EN IEC 60598-2-18:2022
DIN EN 60598-2-19:1992-08 + A2:1999-04; IEC 598-2-19:1981; IEC 60598-2-19:1981/A2:1997; DIN EN 60598-2-20:2015-10; IEC 60598-2-20:2014; DIN EN 60598-2-21:2015-10; IEC 60598-2-21:2014; DIN EN 60598-2-22:2020-12; IEC 60598-2-22:2014 + COR1:2015 + COR2:2016 + A1:2017; DIN EN 60598-2-24:2014-04; IEC 60598-2-24:2013; DIN EN 60598-2-25:2005-07; IEC 60598-2-25:1994 + Corrigendum 1994 + A1:2004
DIN EN 55024:2016; IEC/CISPR 24:2010+A1:2015; DIN EN 55032:2012; CISPR 32:2012 + Cor.1: 2012 + Cor.2:2012; DIN EN 55032 :2022; IEC/ CISPR 32:2015 + COR1:2016 + A1:2019; DIN EN 55035:2018; CISPR 35:2016; DIN EN 60034 -1:2011; IEC 60034 -1:2010
IEC 62040-2:2005; DIN EN IEC 62040-2:2019-04; IEC 62040-2:2016; DIN EN 62920:2024-05; EN 62920:2017 + A11:2020 + A1:2021; IEC 62920:2017 + A1:2021; OIML R 137-1&2:2014; DIN EN 60945:2003-07; IEC 60945:2002; DNV-CG-0339:2021-08
DIN EN 61558-2-5:2011-03; (IEC 61558-2-5:2010); Deutsche Fassung EN 61558-2-5:2010; DIN EN 61558-2-6:2010-04; (IEC 61558-2-6:2009); Deutsche Fassung EN 61558-2-6:2009; DIN EN61558-2-16:2014-06; (IEC 61558-2-16:2009 + A1:2013); Deutsche Fassung EN 61558-2-16:2009 + A1:2013; DIN EN 60950-1:2014-08; (IEC 60950-1:2005, modifiziert + Cor.:2006 + A1:2009, modifiziert + A1:2009/Cor.:2012 + A2:2013, modifiziert); Deutsche Fassung EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011 + AC:2011 + A2:2013
IEC 60950-1:2005 + A1:2009 + A2:2013; EN 60950-1:2006 + A11:2009 + A1:2010+ A12 :2011 + A2:2013; DIN EN62040-1:2013-11; IEC 62040-1:2008 + Corr:2008 + A1:2013; EN 62040-1:2008 + Corr:2009 + A1:2013; DIN EN IEC 62368-1:2021-05; IEC 62368-1:2018; DIN EN 61010-1:2020-03
DIN EN 60968:2016-07; DIN EN 61347-1:2021-08; DIN EN 61347-2-11:2019-11; DIN EN 61347-2-13:2017-10; DIN EN IEC 62031:2020 + A11:2022-07; DIN EN 62560:2019-10
DIN EN IEC 61204-3:2018-11; IEC 61204-3:2016; DIN EN 61326-1:2013-07; IEC 61326-1:2012; DIN EN IEC 61326-1:2022-11; IEC 61326-1:2020; DIN EN 61326-2-1:2013-08; IEC 61326-2-1:2012
IEC 61326-3-2:2017; DIN EN 61547:2010-03; IEC 61547:2009; DIN EN 61800-3:2012-09; IEC 61800-3:2004 + A1:2011; DIN EN IEC 61800-3:2019-04; IEC 61800-3:2017; DIN EN 62040-2:2006-07
ISO 13849-1; DIN EN IEC 62061; IEC 62061; DIN EN ISO 10218-1; ISO 10218-1; DIN ISO/TS 15066; ISO/TS 15066; DIN EN ISO 13482; ISO 13482; ISO 26262-2; ISO 26262-3; ISO 26262-4; ISO 26262-5; ISO 26262-6; ISO 26262-7
IEC 61010-1:2010 + COR:2011 + A1:2016, modifiziert + A1:2016/COR1:2019; DIN EN IEC 61010-2-010:2022-12; IEC 61010-2-010:2019; DIN EN 61010-2-011:2017-12; IEC 61010-2-011:2016; DIN EN 61010-2-012:2017-09; IEC 61010-2-012:2016
IEC 60601-1-2 : 2014-02; IEC 60601-1-2 : 2007-03; IEC 60601-2-10 : 2016-04; IEC 60601-2-18 : 2009-08; IEC 60601-2-18 : 1996-08; IEC 61010-2-040 : 2015-07; IEC 61010-1 : 2010-06; IEC 61010-2-040 : 2005-04; IEC 61010-1 : 2001-02
DIN EN 61010-2-020:2017-12; IEC 61010-2-020:2016; DIN EN IEC 61010-2-030:2022-11; IEC 61010-2-030:2017; DIN EN IEC 61010-2-032:2023-02; IEC 61010-2-032:2019
DIN EN IEC 61010-2-033:2023-02; IEC 61010-2-033:2019; DIN EN IEC 61010-2-034:2022-10; IEC 61010-2-034:2017; DIN EN IEC 61010-2-051:2023-01
DIN EN 60601-1; IEC 60601-1; DIN EN 60601-1-1; IEC 60601-1-1; DIN EN 61010-2-101; IEC 61010-2-101; DIN EN 60601 -2-10; IEC 60601-2-10; DIN EN 60601-2-18; IEC 60601-2-18; DIN EN IEC 61010-2-040; DIN EN 61010-2-040
DIN EN IEC 61010-2-040:2023-02; VDE 0411-2-040 : 2023-02; DIN EN 61010-2-040 : 2016-06; DIN EN 61010-2-040 : 2006-02; DIN EN 61010-2-101 : 2017-10; VDE 0411-2-101 : 2017-10; DIN EN 61010-2-101 : 2003-09; VDE 0411-2-101 : 2003-09
IEC 61010-2-051:2018; DIN EN IEC 61010-2-081:2022-07; IEC 61010-2-081:2019; DIN EIN IEC 61010-2-201:2019-04; IEC 61010-2-201:2017; DIN EN 61010-31:2023-02
IEC 61010-2-101; IEC 61326-2-6
IEC 61010-031:2015; A1:2018; COR1:2018
EN 12405 -1:2021; DIN EN 13611:2011 -12; EN 13611:2007+A2:2011; DIN EN 13611:2022 -01; EN 13611:2019 + AC:2021; DIN EN 14236:2008 -06; EN 14236:2007; DIN EN 14236:2018 -12; EN 14236:2018; DIN EN 16314:2013 -09; EN 16314:2013; DIN EN 45501:1992 -11
EN 45501:1992; DIN EN 45501: 2016 -03; EN 45501 :2015; DIN EN 50121 -3-2:2017 -11; DIN EN 50121 -3-2/A1:2020 -11; EN 50121 -3-2:2016; EN 50121 -3-2:2016/A1:2019; DIN EN 50121 -4: 20 17-11; DIN EN 50121 -4/A1:2020 -11; EN 50121 -4:20 16; EN 50121 -4:2016/A1:2019
DIN EN 50130-4; EN 50130-4; DIN EN 50130-4; EN 50130-4; DIN EN 50148; EN 50148; DIN EN 50270; EN 50270
DIN EN 50270; EN 50270; DIN EN 50293; EN 50293; DIN EN 50370 -2; EN 50370 -2; DIN EN 55011; IEC/CISPR 11; DIN EN 55011
DIN EN 60730-2-5:2020-01; IEC 60730-2-5:2013+A1:2017; DIN EN 60730-2-6:2020-10; IEC 60730-2-6:2015+A1:2019; DIN EN IEC 60730-2-7:2020-10; IEC 60730-2-7:2015
DIN EN 60730-2-6:2020-10; DIN EN IEC 60730-2-7:2020-10; DIN EN IEC 60730-2-9:2021-01; DIN EN IEC 60730-2-11:2021-05; DIN EN IEC 60730-2-13:2018-09
DIN EN IEC 60730-2-8:2022-11; IEC 60730-2-8:2018+A1:2021; DIN EN IEC 60730-2-9:2021-01; IEC 60730-2-9:2015+A1:2018+A2:2020; DIN EN IEC 60730-2-11:2021-05; IEC 60730-2-11:2019
DIN EN IEC 60730-2-13:2018-09; IEC 60730-2-13: 2017 + COR1:2018; DIN EN IEC 60730-2-14 :20 23 -03; IEC 60730 -2-14: 2017+A1:2019+A2:2021 CSV; DIN EN IEC 60730-2-15:2020-02; IEC 60730 -2-15:2017
DIN EN IEC 61326 -2-1: 2022 -11; IEC 61326 -2-1:20 20; DIN EN 61326 -2-2:2013 -08; IEC 61326 -2-2:2012
DIN EN IEC 61326-2-2:2022-11; IEC 61326-2-2:2020; DIN EN 61326-2-3:2013-07; IEC 61326-2-3:2012
DIN EN IEC 61326 -2-3:20 22 -11; IEC 61326 -2-3:20 20; DIN EN 61326 -2-4:2013 -07; IEC 61326 -2-4:2012
DIN EN IEC 61326-2-4:2022-11; IEC 61326-2-4:2020; DIN EN 61326-2-5:2013-08; IEC 61326-2-5:2012
DIN EN IEC 61326-2-5:2022-11; IEC 61326-2-5:2020; DIN EN 61326-3-1:2008-11; IEC 61326-3-1:2008; DIN EN 61326-3-1:2018-04
DIN EN 60601-1-2; IEC 60601-1-2; DIN EN IEC 61326-2-6; DIN EN 61326-2-6
DIN EN IEC 61326-2-6 : 2022-11; VDE 0843-20-2-6 : 2022-11; DIN EN 61326-2-6 : 2013-09; VDE 0843-20-2-6 : 2013-09; DIN EN 61326-2-6 : 2006-10; VDE 0843-20-2-6 : 2006-10; IEC 60601-1: 2005-12; IEC 60601-1 : 1988; IEC 60601-1-1 : 2000-12
IEC 61326-3-1:2017; DIN EN 61326-3-2:2008-11; IEC 61326-3-2:2008; DIN EN IEC 61326-3-2:2019-10
ISO 26262-8; ISO 26262-9; ISO 26262-12; ISO 25119-1; ISO 25119-2; ISO 25119-3; ISO 25119-4
IEC/ CISPR 11:2015 + A1:2016 + A2:2019; DIN EN 55014 -1:2012 -05; IEC/CISPR 14 -1:2005 + A1:2008 + A2:2011; DIN EN IEC 55014 -1: 2022 -12; IEC/ CISPR 14 -1:202 0; DIN EN 55014 -2:2009 -06; IEC/CISPR 14 -2:1997 + A1:2001 + A2:2008; DIN EN IEC 55014 -2:2022 -10
IEC/ CISPR 14 -2:202 0; DIN EN 55015: 2014 -03; IEC/ CISPR 15:2013 + IS1:2013 + IS2:2013; DIN EN IEC 55015:2020 -07; IEC/ CISPR 15:20 18; DIN EN 55022:2011 -12; IEC/CISPR 22:2008; DIN EN 55024:2011 -09; IEC/CISPR 24:2010
DIN EN IEC 61558-1:2019-12; DIN EN 61558-2-1:2007-11; DIN EN 61558-2-2:2007-11; DIN EN 61558-2-4:2009-12
DIN EN 60601-1; IEC 60601-1; DIN EN 60601-1-1; IEC 60601-1-1
DIN EN 60601-1; VDE 0750-1; DIN EN 60601-1-1; VDE 0750-1-1
DIN EN 60601-1-2; VDE 0750-1-2; DIN EN 60601-2-10; VDE 0750-2-10; DIN EN 60601-2-18; VDE 0750-2-18
DIN EN 60947 -1:2011 -10; IEC 60947 -1:2007 + A1:2010; DIN EN IEC 60947 -1: 2022 -03; IEC 60947 -1:20 20; DIN EN 60947 -2:2014 -01; IEC 60947 -2:2006 + A1:2009 + A2:2013; DIN EN 60947 -2:20 20 -11; IEC 60947 -2:2016 + A1:201 9 + COR1:2019; DIN EN 60947 -5-1:2018 -03; IEC 60947 -5-1:2016 + COR1:2016
DIN EN 61508-1: 2011-02; IEC 61508-1: 2010-04; DIN EN 61508-2: 2011-02; IEC 61508-2: 2010-04; DIN EN 61508-3: 2011-02; IEC 61508-3: 2010-04; DIN EN ISO 13849-1: 2016-06
Read from the scope as published by DAKKS. Register refreshed 2026-11-20.
Scope as published by DAKKS
80 lines
ISO/IEC 17025
ActiveD-PL-22131-01-00
ISO/IEC 17025
ActiveD-PL-22131-01-01
ISO/IEC 17025
ActiveD-PL-22131-01-02
ISO/IEC 17025
ActiveD-PL-22131-01-03
ISO/IEC 17025
ActiveD-PL-22131-01-04
ISO/IEC 17025
WithdrawnD-PL-22131-01-05
Location
Labs with overlapping accredited scope in Germany
- ELMAC GmbH EMV-Labor J. BühneBondorf · ~57 kmDAKKSShares 3 accredited test methodsEN ISO 9001IEC 60601-1-2IEC 61326-2-6
- TQ-Systems GmbH TQ Product Compliance Center AugsburgAugsburg · ~187 kmDAKKSShares 3 accredited test methodsEN ISO 9001IEC 60601-1-2IEC 61326-2-6
- Intertek DeutschlandKaufbeuren · ~197 kmDAKKSShares 3 accredited test methodsEN ISO 9001IEC 60601-1IEC 60601-1-2
- EMC Testhaus GmbH & Co. KGSiegen · ~209 kmDAKKSShares 3 accredited test methodsEN ISO 9001IEC 60601-1-2IEC 61326-2-6
- TÜV Technische Überwachung Hessen GmbH EMV-LaborKassel · ~264 kmDAKKSShares 3 accredited test methodsEN ISO 9001IEC 60601-1-2IEC 61326-2-6
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.