DHHS/FDA/OII/HFP/OLOAS/ORTS/ATLHAFL
60 Eighth Street NE, 30309, Atlanta, GA, United States
- Accredited standards
- 19
- A2LA certificates
- 2
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 19 standard numbers and the 0 official names we hold. When no standard matches, it searches the method text of every scope line.
AOAC19
AOAC 966.23
AOAC 966.24
AOAC 967.22
AOAC 977.13
AOAC 978.18
AOAC 981.12
AOAC 985.33
AOAC 986.26
AOAC 988.13
AOAC 990.03
AOAC 991.20
AOAC 991.31
Show all 19
AOAC 995.10
AOAC 996.01
AOAC 2004.03
AOAC 2004.06
AOAC 2011.03
AOAC 2011.11
AOAC 2011.14
FDA Bacteriological Analytical Manual (BAM); Official Methods of Analysis of AOAC International (AOAC); AOAC 966.23; AOAC 966.24; AOAC 2004.06; AOAC 981.12
AOAC 2004.03; AOAC 2011.03; BAM Chapter 5; AOAC 966.23; BAM Chapters 12, 13A; AOAC 978.18
AOAC 985.33; AOAC 967.22; AOAC 2011.11; LIB 4488
AOAC 991.31; EAM 4.7; SRL-ACNA.013; EAM 4.6; AOAC 986.26; NMCA, Chapter 19; AOAC 988.13; C003.01; AOAC Chapter 16; MPM; AOAC 996.01; AOAC 977.13; M1 JAOAC Vol. 99, No. 1 (2016); AOAC 2011.14 (ICP); SOP-000547; JAOAC Vol. 82, 85 (1999); CP 7303.844; CP 7303.842; AOAC 995.10; AOAC 991.20 (Kjeldahl); AOAC 990.03
Read from the A2LA scope documents we downloaded on 2026-10-27. Register refreshed 2026-11-20.
Scope as published by A2LA
7 lines
ISO/IEC 17025
Active5807.01
The scope document we hold says it is valid until 2026-11-30.
Accredited scope, certificate 5807.01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | FDA Bacteriological Analytical Manual (BAM); Official Methods of Analysis of AOAC International (AOAC); AOAC 966.23; AOAC 966.24; AOAC 2004.06; AOAC 981.12 | Foods and Feeds | - |
| 2 | AOAC 2004.03; AOAC 2011.03; BAM Chapter 5; AOAC 966.23; BAM Chapters 12, 13A; AOAC 978.18 | - | - |
| 3 | ISO/IEC 17025:2017; A2LA R204 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
Active5807.02
The scope document we hold says it is valid until 2026-11-30.
Accredited scope, certificate 5807.02
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Elemental Analysis Manual (EAM); FDA Bacteriological Analytical Manual (BAM); FDA Compliance Program (CP); FDA Laboratory Information Bulletins (LIB); Internal Methods (SRL-ACNA); Journal of AOAC International (JAOAC); Macroanalytical Procedures Manual (MPM); Newburger’s Manual of Cosmetic Analysis (NMCA); Official Methods of Analysis of AOAC International (AOAC) | Foods; Feeds; Drugs; and Food Additives | - |
| 2 | AOAC 991.31; EAM 4.7; SRL-ACNA.013; EAM 4.6; AOAC 986.26; NMCA, Chapter 19; AOAC 988.13; C003.01; AOAC Chapter 16; MPM; AOAC 996.01; AOAC 977.13; M1 JAOAC Vol. 99, No. 1 (2016); AOAC 2011.14 (ICP); SOP-000547; JAOAC Vol. 82, 85 (1999); CP 7303.844; CP 7303.842; AOAC 995.10; AOAC 991.20 (Kjeldahl); AOAC 990.03 | Corn; Peanut Butter; Wheat Flour; Fish; Shrimp; Ceramic Food Ware | - |
| 3 | AOAC 985.33; AOAC 967.22; AOAC 2011.11; LIB 4488 | - | - |
| 4 | ISO/IEC 17025:2017; A2LA R204 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- Silliker, Inc. dba Merieux NutriSciences GainesvilleGainesville, FL · ~496 kmA2LAShares 2 accredited test methodsAOAC 966.23AOAC 991.31
- Deibel Laboratories, Inc.Madison, WI · ~1,123 kmA2LAShares 2 accredited test methodsAOAC 2004.03AOAC 966.23
- Minnesota Valley TestingNew Ulm, MN · ~1,459 kmA2LAShares 2 accredited test methodsAOAC 2004.03AOAC 966.23
- Silliker, Inc. dba Merieux NutriSciences SalidaSalida, CA · ~3,320 kmA2LAShares 2 accredited test methodsAOAC 966.23AOAC 991.31
- Silliker, Inc. dba Merieux NutriSciences GeorgiaStone Mountain, GA · ~23 kmA2LAShares 1 accredited test methodAOAC 966.23
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.