Schwille Elektronik Produktions- und Vertriebs
Benzstraße 1a, 85551, Kirchheim, Germany
- Accredited standards
- 26
- DAKKS certificates
- 2
- Site in our directory
- 1
What this lab is accredited for
Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 26 standard numbers and the 23 official names we hold. When no standard matches, it searches the method text of every scope line.
CISPR8
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard
CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment
CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
CISPR 24Information technology equipment - Immunity characteristics - Limits and methods of measurement
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements
CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirements
IEC 61000 series8
IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
EN4
EN 50121-3-2Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
EN 50121-4Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus
EN 50130-4Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
EN 50293
IEC3
IEC 60974-10
IEC 61496-1
IEC 61547Equipment for general lighting purposes - EMC immunity requirements
IEC 61326 series3
IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
IEC 61326-2-2Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable testing, measuring and monitoring equipment used in low-voltage distribution systems
IEC 61326-2-6Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical electrical equipment
DIN EN 50130 -4; DIN EN 50293; DIN EN 55011; DIN EN 55014 -1; VDE 0830-1-4
DIN EN 55014 -2; DIN EN 61326 -1; DIN EN 61326 -2-2; VDE 0875-14-2; VDE 0843-20-1
DIN EN IEC 55015; DIN EN 61547; DIN EN 60974 -10:2016 -10; VDE 0875-15-1; VDE 0875-15-2
DIN EN 61326 -2-6; DIN EN 55022; DIN EN 55024; DIN EN 55032:2016 -02; DIN EN 55035:2018 -04
DIN EN 61000 -4-2:2009 -12; DIN EN 61000 -4-4:2013 -04; DIN EN 61000 -4-5:2015 -03; DIN EN 61000 -4-11:2005 -02; VDE 0847-4-2
DIN EN IEC 61000 -6-1:2019 - 11; DIN EN IEC 61000 -6-2:2019 - 11; DIN EN 61000 -6-3:2011 -09; VDE 0839-6-1; VDE 0839-6-2
DIN EN 61000 -6-4:2011 -09; DIN EN 50121 -3-2; DIN EN 50121 -4:2017 -11; VDE 0839-6-4; VDE 0115-121-3-2
DIN EN 61496 -1:2014 -05; VDE 0113-201; EN 61496; EN 61496-1; IEC 61496-1
Read from the scope as published by DAKKS. Register refreshed 2026-11-06.
Scope as published by DAKKS
12 lines
ISO/IEC 17025
ActiveD-PL-12003-01-00
ISO/IEC 17025
ActiveD-PL-12003-01-01
Location
Labs with overlapping accredited scope in Germany
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.