EMC srl
Via Greto di Cornigliano, 6 R, 16152, Genova, Italy
Visit website- Accredited standards
- 9
- ACCREDIA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the ACCREDIA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 9 standard numbers and the 9 official names we hold. When no standard matches, it searches the method text of every scope line.
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
CISPR 16-2-1Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-1: Methods of measurement of disturbances and immunity - Conducted disturbance measurements
CISPR 16-2-3Specification for radio disturbance and immunity measuring apparatus and methods - Part 2-3: Methods of measurement of disturbances and immunity - Radiated disturbance measurements
EN 50121-3-2Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
EN 50121-4Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus
IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments
IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
CEI EN 61000-6-4:2007/A1:2013; CEI EN 61000-6-4:2020; EN 61000-6-4:2007/A1:2011; EN IEC 61000-6-4:2019; IEC 61000-6-4:2006/A1:2010; IEC 61000-6-4:2018; CEI EN 61000-6-3:2007/A1:2013; CEI EN IEC 61000-6-3:2021; EN 61000-6-3:2007/A1:2011/AC:2012; EN IEC 61000-6-3:2021; IEC 61000-6-3:2006/A1:2010; IEC 61000-6-3:2020; CEI EN 55016-2-1:2015/A1:2018; CISPR 16-2-1:2014/AMD1:2017/Cor1:2020; EN 55016-2-1:2014/A1:2017/AC:2020; CEI EN 55016-2-3:2017/A1:2020; CISPR 16-2-3:2016/AMD1:2019; EN 55016-2-3:2017/A1:2019; CEI EN 61000-4-5:2016/A1:2018; EN 61000-4-5:2014/A1:2017; IEC 61000-4-5:2014/AMD1:2017; CEI EN 61000-4-4:2013; EN 61000-4-4:2012; IEC 61000-4-4:2012; CEI EN 55011:2018/A1:2019/A11:2020/A2:2021; CISPR 11:2015/AMD1:2016/AMD2:2019; EN 55011:2016/A1:2017/A11:2020/A2:2021; CEI EN 50121-4:2017/A1:2019; EN 50121-4:2016/A1:2019; CEI EN 50121-3-2:2017/A1:2019; EN 50121-3-2:2016/A1:2019
Read from the scope as published by ACCREDIA. Register refreshed 2026-11-20.
Scope as published by ACCREDIA
2 lines
ISO/IEC 17025
Active01212
Accredited scope, certificate 01212
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | CEI EN 61000-6-4:2007/A1:2013; CEI EN 61000-6-4:2020; EN 61000-6-4:2007/A1:2011; EN IEC 61000-6-4:2019; IEC 61000-6-4:2006/A1:2010; IEC 61000-6-4:2018; CEI EN 61000-6-3:2007/A1:2013; CEI EN IEC 61000-6-3:2021; EN 61000-6-3:2007/A1:2011/AC:2012; EN IEC 61000-6-3:2021; IEC 61000-6-3:2006/A1:2010; IEC 61000-6-3:2020; CEI EN 55016-2-1:2015/A1:2018; CISPR 16-2-1:2014/AMD1:2017/Cor1:2020; EN 55016-2-1:2014/A1:2017/AC:2020; CEI EN 55016-2-3:2017/A1:2020; CISPR 16-2-3:2016/AMD1:2019; EN 55016-2-3:2017/A1:2019; CEI EN 61000-4-5:2016/A1:2018; EN 61000-4-5:2014/A1:2017; IEC 61000-4-5:2014/AMD1:2017; CEI EN 61000-4-4:2013; EN 61000-4-4:2012; IEC 61000-4-4:2012; CEI EN 55011:2018/A1:2019/A11:2020/A2:2021; CISPR 11:2015/AMD1:2016/AMD2:2019; EN 55011:2016/A1:2017/A11:2020/A2:2021; CEI EN 50121-4:2017/A1:2019; EN 50121-4:2016/A1:2019; CEI EN 50121-3-2:2017/A1:2019; EN 50121-3-2:2016/A1:2019 | Apparecchiature elettriche ed elettroniche per ambienti industriali; Apparecchiature elettriche ed elettroniche per gli ambienti residenziali, commerciali e dell'industria leggera; Apparecchiature elettriche ed elettroniche; Apparecchiature industriali, scientifiche e medicali; Apparecchiature per applicazioni ferroviarie, tranviarie, filoviarie e metropolitane: apparecchi di segnalamento e telecomunicazioni; Apparecchiature per applicazioni ferroviarie, tranviarie, filoviarie e metropolitane: materiale rotabile | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. EMC srl
Via Greto di Cornigliano, 6 R
16152 Genova GE
Legenda/Note
Allegato al certificato di accreditamento n. 01212 rev. 3 del 23/01/2025
UNI CEI EN ISO/IEC 17025:2018
Revisione: 16
Sede A
Data: 18/03/2025
pag. 2 di 2
Il simbolo (1), se presente, indica: "Materiale/Prodotto/Matrice" non previsto dal metodo ma assimilabile/The symbol (1), if present, means: Material/Product/Matrix not
provided for by the method but acceptable
Per la definizione della “categoria" di prova indicata nel titolo, si veda il Regolamento Generale ACCREDIA RG-02/For the definition of the test “category” indicated in the title,
see ACCREDIA General Regulation RG-02.
Il QRcode consente di accedere direttamente al sito www.accredia.it per verificare la validità dell'elenco prove e del certificato di accreditamento
rilasciato al laboratorio/The QRcode allows to directly access to the website www.accredia.it to verify the validity of the test list and of the
accreditation certificate issued to the laboratory.
L’eventuale simbolo “X” riportato nella colonna “O&I” indica che il laboratorio è accreditato anche per fornire opinioni e interpretazioni basate sui
risultati delle specifiche prove contrassegnate/Any "X" symbol in the "O&I" column indicates that the laboratory is also accredited to provide opinions
and interpretations based on the results of the specific marked tests.
L'eventuale simbolo (*) indica che è attiva una sospensione dell’accreditamento per la specifica attività riportata a fianco/Any symbol (*) indicates that
a suspension of accreditation is active for the specific activity shown next to it. | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the ACCREDIA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ACCREDIA entry linked above.