United States

Bird Service Center

30303 Aurora Rd., 44139, Solon, OH, United States

Visit website
A2LA 2626.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
18
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 18 scope lines.

A2LA certificate 2626.01 · 18 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; IEC 17025; ANSI/NCSL Z540-1-1994 BIRD SERVICE CENTER 30303-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2626.01) Revised 03/13/2025 Page 2 of 17 Parameter/Range Range CMC2, 3, 4, 5, 6 (±) Comments DC Resistance – Generate (1.2 to 12) Ω (12 to 120) Ω 120 Ω to 1.2 kΩ (1.2 to 12) kΩ (12 to 120) kΩ 120 kΩ to 1.2 MΩ (1.2 to 12) MΩ (12 to 120) MΩ 120 MΩ to 1.2 GΩ 23 µΩ/Ω + 1 mΩ 19 µΩ/Ω + 1 mΩ 23 µΩ/Ω + 2 mΩ 45 µΩ/Ω + 20 mΩ 31 µΩ/Ω + 200 mΩ 41 µΩ/Ω + 2 Ω 48 µΩ/Ω + 30 Ω 0.36 mΩ/Ω + 2.5 kΩ 0.95 mΩ/Ω + 100 kΩ Fluke 5560A DC Resistance – Measure (0 to 10) Ω (10 to 100) Ω 100 Ω to 1 kΩ (1 to 10) kΩ (10 to 100) kΩ 100 kΩ to 1 MΩ (1 to 10) MΩ (10 to 100) MΩ 100 MΩ to 1 GΩ 30 µΩ/Ω + 0.14 mΩ 29 µΩ/Ω + 1.4 mΩ 22 µΩ/Ω + 1.4 mΩ 22 µΩ/Ω + 14 mΩ 22 µΩ/Ω + 0.14 Ω 28 µΩ/Ω + 8.0 Ω 0.012 % + 0.18 kΩ 0.024 % + 1.8 kΩ 1.3 % + 18 kΩ Agilent 3458A, opt 002 (2- year specifications) DC Current – Generate (0 to 220) µA 220 µA to 2.2 mA (2.2 to 22) mA (22 to 220) mA 220 mA to 2.2 A (2.2 to 11) A (1.2 to 3.1) A (3.1 to 12) A (12 to 30.2) A 41 µA/A + 6.0 nA 37 µA/A + 7.0 nA 39 µA/A + 40 nA 49 µA/A + 0.70 µA 86 µA/A + 12 µA 0.37 mA/A + 0.48 mA 0.23 mA/A + 0.15 mA 0.23 mA/A + 0.25 mA 0.8 mA/A + 0.5 mA Fluke 5720A & Fluke 5725A Fluke 5560A DC Current – Measure (1 to 10) µA (10 to 100) µA 100 µA to 1 mA (1 to 10) mA (10 to 100) mA 100 mA to 1 A 39 µA/A + 0.14 nA 38 µA/A + 1.2 nA 38 µA/A + 9.0 nA 42 µA/A + 90 nA 57 µA/A + 0.90 µA 0.14 mA/A + 18 µA Agilent 3458A, opt 002 (2- year specifications) DC Power – Generate (1 to 600) W (>600 to 5000) W 0.013 % 0.027 % Fluke 5560A
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2626.01) Revised 03/13/2025 Page 3 of 17 Parameter/Range Frequency CMC2, 3, 4, 5, 6 (±) Comments AC Voltage – Generate (0 to 2.2) mV (2.2 to 22) mV (22 to 220) mV 220 mV to 2.2 V (2.2 to 22) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz 0.072 % + 4.0 µV 0.12 % + 4.0 µV 0.051 % + 4.0 µV 0.12 % + 4.0 µV 0.095 % + 5.0 µV 0.16 % + 10 µV 0.24 % + 20 µV 0.39 % + 20 µV 0.029 % + 20 µV 0.019 % + 20 µV 0.011 % + 20 µV 0.031 % + 20 µV 0.079 % + 20 µV 0.11 % + 20 µV 0.14 % + 20 µV 0.31 % + 20 µV 0.024 % + 20 µV 0.0099 % + 20 µV 0.0083 % + 20 µV 0.022 % + 20 µV 0.047 % + 20 µV 0.091 % + 20 µV 0.14 % + 20 µV 0.29 % + 20 µV 0.024 % + 20 µV 0.0092 % + 20 µV 0.0047 % + 20 µV 0.0077 % + 20 µV 0.011 % + 20 µV 0.026 % + 20 µV 0.10 % + 20 µV 0.18 % + 20 µV 0.024 % + 20 µV 0.0093 % + 20 µV 0.0048 % + 20 µV 0.0077 % + 20 µV 0.010 % + 20 µV 0.029 % + 20 µV 0.10 % + 20 µV 0.17 % + 20 µV Fluke 5720A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2626.01) Revised 03/13/2025 Page 4 of 17 Parameter/Range Frequency CMC2, 3, 4, 5, 6 (±) Comments AC Voltage – Generate (cont) (22 to 220) V (220 to 1100) V (220 to 750) V (15 to 17) V (28 to 32) V (56 to 64) V (110 to 128) V (13 to 180) V (25 to 360) V (75 to 1008) V (1.2 to 12) mV (12 to 120) mV (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (15 to 50) Hz 50 Hz to 1 kHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 30) kHz (30 to 50) kHz (50 to 100) kHz (45 to 65) Hz (45 to 65) Hz (45 to 65) Hz (45 to 65) Hz (45 to 65) Hz (45 to 65) Hz (45 to 65) Hz (3 to 5) Hz (5 to 10) Hz 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (3 to 5) Hz (5 to 10) Hz 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz 0.024 % + 20 µV 0.0096 % + 20 µV 0.0064 % + 20 µV 0.0092 % + 20 µV 0.017 % + 20 µV 0.093 % + 20 µV 0.44 % + 20 µV 0.83 % + 20 µV 0.030 % + 20 µV 0.0078 % + 20 µV 0.012 % + 20 µV 0.018 % + 20 µV 0.061 % + 20 µV 0.063 % + 20 µV 0.23 % + 20 µV 0.0051 % 0.0052 % 0.0059 % 0.0056 % 0.0053 % + 1.6 mV 0.0067 % + 3.2 mV 0.007 % + 10 mV 0.2 % + 7 µV 0.071 % + 7 µV 0.027 % + 6 µV 0.03 % + 6 µV 0.12 % + 15 µV 0.62 % + 30 µV 0.19 % + 7 µV 0.068 % + 7 µV 0.011 % + 6 µV 0.027 % + 8 µV 0.062 % + 20 µV 0.16 % + 30 µV Fluke 5720A Where V*F ≤2.2*10 7 V*Hz Fluke 6105A Fluke 5560A
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2626.01) Revised 03/13/2025 Page 5 of 17 Parameter/Range Frequency CMC2, 3, 4, 5, 6 (±) Comments AC Voltage – Generate (cont) 120 mV to 1.2 V (1.2 to 12) V (12 to 120) V (12 to 120) V (120 to 330) V (330 to 1020) V (3 to 5) Hz (5 to 10) Hz (10 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (3 to 5) Hz (5 to 10) Hz (10 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (3 to 5) Hz (5 to 10) Hz (10 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (3 to 5) Hz (5 to 10) Hz 10 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (3 to 5) Hz (5 to 10) Hz 10 Hz to 10 kHz 0.19 % + 75 µV 0.068 % + 70 µV 0.011 % + 60 µV 0.011 % + 8 µV 0.023 % + 14 µV 0.054 % + 40 µV 0.15 % + 80 µV 0.19 % + 0.75 mV 0.068 % + 0.75 mV 0.011 % + 0.35 mV 0.011 % + 50 µV 0.023 % + 50 µV 0.055 % + 0.13 mV 0.16 % + 0.6 mV 0.19 % + 7.5 mV 0.068 % + 7.5 mV 0.012 % + 3.5 mV 0.011 % + 0.5 mV 0.023 % + 0.5 mV 0.054 % + 1.3 mV 0.13 % + 20 mV 0.19 % + 75 mV 0.069 % + 75 mV 0.018 % + 8 mV 0.048 % + 8 mV 0.17 % + 13 mV 0.19 % + 75 mV 0.068 % + 75 mV 0.013 % + 80 mV Fluke 5560A AC Voltage – Measure (0 to 10) mV (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 0.056 % + 13 µV 0.037 % + 11 µV 0.056 % + 11 µV 0.16 % + 11 µV 0.59 % + 11 µV 4.6 % + 12 µV Agilent 3458A, opt 002 (2-year specifications)
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2626.01) Revised 03/13/2025 Page 6 of 17 Parameter/Range Frequency CMC2, 3, 4, 5, 6 (±) Comments AC Voltage – Measure cont. (10 to 100) mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 1000) V (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 2) MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 0.013 % + 5.1 µV 0.013 % + 2.8 µV 0.021 % + 2.8 µV 0.040 % + 2.8 µV 0.097 % + 2.8 µV 0.35 % + 12 µV 1.2 % + 12 µV 1.7 % + 12 µV 0.013 % + 51 µV 0.013 % + 28 µV 0.021 % + 28 µV 0.039 % + 28 µV 0.097 % + 28 µV 0.35 % + 0.12 mV 1.2 % + 0.12 mV 1.7 % + 0.12 mV 0.013 % + 0.51 mV 0.013 % + 0.28 mV 0.021 % + 0.28 mV 0.039 % + 0.28 mV 0.097 % + 0.28 mV 0.35 % + 1.2 mV 1.2 % + 1.2 mV 1.7 % + 1.2 mV 0.028 % + 5.1 mV 0.028 % + 2.8 mV 0.028 % + 2.8 mV 0.045 % + 2.8 mV 0.14 % + 2.8 mV 0.47 % + 12 mV 1.7 % + 12 mV 0.051 % + 51 mV 0.051 % + 28 mV 0.074 % + 28 mV 0.14 % + 28 mV 0.35 % + 28 mV Agilent 3458A, opt 002 (2-year specifications)
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2626.01) Revised 03/13/2025 Page 7 of 17 Parameter/Range Frequency CMC2, 3, 4, 5, 6 (±) Comments AC Current – Generate (0 to 220) µA 220 µA to 2.2 mA (2.2 to 22) mA (22 to 220) mA 220 mA to 2.2 A (2.2 to 11) A (0.2 to 0.5) A (0.4 to 1) A (0.8 to 2) A (2 to 5) A (4 to 10) A (12 to 120) µA (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 20 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (45 to 65) Hz (45 to 65) Hz (45 to 65) Hz (45 to 65) Hz (45 to 65) Hz 3 Hz to 5 kHz (5 to 10) kHz (10 to 30) kHz 0.026 % + 16 nA 0.017 % + 10 nA 0.014 % + 8.0 nA 0.033 % + 12 nA 0.11 % + 65 nA 0.026 % + 40 nA 0.017 % + 35 nA 0.013 % + 35 nA 0.022 % + 0.11 µA 0.11 % + 0.65 µA 0.026 % + 0.4 µA 0.017 % + 0.35 µA 0.013 % + 0.35 µA 0.021 % + 0.55 µA 0.11 % + 5.0 µA 0.026 % + 4.0 µA 0.017 % + 3.5 µA 0.014 % + 2.5 µA 0.022 % + 3.5 µA 0.11 % + 10 µA 0.027 % + 35 µA 0.048 % + 80 µA 0.71 % + 0.16 mA 0.049 % + 0.17 mA 0.097 % + 0.38 mA 0.36 % + 0.75 mA 0.0093 % + 3.0 µA 0.012 % + 6.0 µA 0.015 % + 12 µA 0.018 % + 30 µA 0.022 % + 60 µA 0.025 % + 10 nA 0.12 % + 40 nA 0.39 % + 1 µA Fluke 5720A & Fluke 5725A Fluke 6105A Fluke 5560A
8

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2626.01) Revised 03/13/2025 Page 8 of 17 Parameter/Range Frequency CMC2, 3, 4, 5, 6 (±) Comments AC Current – Generate (cont) 120 µA to 1.2 mA (1.2 to 12) mA (12 to 120) mA (12 to 120) mA 120 mA to 1.2 A (1.2 to 3.1) A (3.1 to 12) A (12 to 30.2) A 3 Hz to 5 kHz (5 to 10) kHz (10 to 30) kHz 3 Hz to 5 kHz (5 to 10) kHz (10 to 30) kHz (3 to 45) Hz 45 Hz to 1 kHz 1 kHz to 5 kHz 5 kHz to 10 kHz 10 kHz to 30 kHz (3 to 45) Hz 45 Hz to 1 kHz 1 kHz to 5 kHz 5 kHz to 10 kHz 10 kHz to 30 kHz (3 to 45) Hz 45 Hz to 1 kHz 1 kHz to 5 kHz 5 kHz to 10 kHz (3 to 45) Hz 45 Hz to 1 kHz 1 kHz to 5 kHz 5 kHz to 10 kHz (3 to 45) Hz 45 Hz to 1 kHz 1 kHz to 5 kHz 0.021 % + 0.1 µA 0.12 % + 0.1 µA 0.39 % + 5 µA 0.021 % + 1 µA 0.12 % + 1 µA 0.39 % + 10 µA 0.022 % + 10 µA 0.015 % + 5 µA 0.022 % + 8 µA 0.12 % + 10 µA 0.39 % + 0.1 mA 0.019 % + 0.1 mA 0.019 % + 50 µA 0.019 % + 80 µA 0.19 % + 0.3 mA 0.39 % + 0.3 mA 0.029 % + 0.5 mA 0.023 % + 0.3 mA 0.03 % + 0.3 mA 0.2 % + 0.5 mA 0.029 % + 1 mA 0.023 % + 0.5 mA 0.03 % + 0.8 mA 0.2 % + 1 mA 0.078 % + 10 mA 0.054 % + 8 mA 0.39 % + 8 mA Fluke 5560A AC Current – Measure (0 to 100) µA (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz 0.47 % + 35 nA 0.18 % + 35 nA 0.079 % + 35 nA 0.079 % + 35 nA Agilent 3458A, opt 002 (2-year specifications)
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2626.01) Revised 03/13/2025 Page 9 of 17 Parameter/Range Frequency CMC2, 5, 6 (±) Comments AC Current – Measure (cont) 100 µA to 1 mA (1 to 10) mA (10 to 100) mA 100 mA to 1 A (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (50 to 100) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz 0.47 % + 0.23 µA 0.18 % + 0.23 µA 0.079 % + 0.23 µA 0.044 % + 0.23 µA 0.079 % + 0.23 µA 0.47 % + 0.46 µA 0.64 % + 1.7 µA 0.47 % + 2.3 µA 0.18 % + 2.3 µA 0.079 % + 2.3 µA 0.044 % + 2.3 µA 0.079 % + 2.3 µA 0.47 % + 4.6 µA 0.64 % + 17 µA 0.47 % + 23 µA 0.18 % + 23 µA 0.079 % + 23 µA 0.044 % + 23 µA 0.079 % + 23 µA 0.47 % + 46 µA 0.64 % + 0.17 mA 0.47 % + 0.23 mA 0.19 % + 0.23 mA 0.10 % + 0.23 mA 0.13 % + 0.23 mA 0.36 % + 0.23 mA 1.2 % + 0.46 mA Agilent 3458A, opt 002 (2-year specifications) AC Power – Generate PF = 1 (1 to 300) W (>300 to 1000) W (>1000 to 3500) W 45 to 65 Hz 45 to 65 Hz 45 to 65 Hz 77 µW/W 91 µW/W 0.10 mW/W Fluke 6105A
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2626.01) Revised 03/13/2025 Page 10 of 17 Parameter/Range Frequency CMC2, 5, 6 (±) Comments AC Power – Measure PF = 1 (1 to 60) W (60 to 200) W (200 to 750) W (750 to 3500) W (45 to 66) Hz (45 to 66) Hz (45 to 66) Hz (45 to 66) Hz 0.055 % 0.051 % 0.049 % 0.050 % Yokogawa WT3000E precision power analyzer Capacitance – Generate (0.10 to 1.2) nF (1.2 to 12) nF (12 to 120) nF 120 nF to 1.2 µF (1.2 to 12) µF (12 to 120) µF 120 µF to 1.2 mF (1.2 to 12) mF (12 to 120) mF 0.18 % + 2 pF 0.18 % + 5 pF 0.18 % + 30 pF 0.18 % + 0.3 nF 0.16 % + 3 nF 0.17 % + 23 nF 0.25 % + 0.25 µF 0.25 % + 3 µF 0.42 % + 30 µF Fluke 5560A Oscilloscopes – Amplitude Square Wave Leveled Sine Wave Amplitude Time Marker Into 50 Ω Into 1 MΩ 5 mVp-p to 5.5 Vp-p 50 kHz (reference) 50 kHz to 10 MHz (10 to 600) MHz 5 mVp-p to 3.5 Vp-p, 600 MHz to 1.1 GHz 80 ms 0.26 % + 40 µV 0.47 % + 40 µV 2.9 % + 100 µV 2.7 % + 100 µV 3.4 % + 100 µV 3.9 % + 100 µV 0.23 µs Fluke 5560A/1G Electrical Calibration of Thermocouples – Generate & Measure Type J (-200 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C 0.42 °C 0.32 °C 0.18 °C 0.17 °C 0.16 °C Fluke 5560A
11

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2626.01) Revised 03/13/2025 Page 11 of 17 Parameter/Range Frequency CMC2, 5, 6 (±) Comments Electrical Calibration of Thermocouples – Generate & Measure cont. Type K Type T Type U (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C (-200 to 0) °C (0 to 600) °C 0.69 °C 0.59 °C 0.54 °C 0.88 °C 1.4 °C 0.80 °C 0.60 °C 0.54 °C 0.87 °C 0.47 °C 0.13 °C Fluke 5560A II. Electrical – RF/Microwave Parameter/Range Frequency CMC2, 5, 6 (±) Comments RF Power – 1 mW Calibration Factor (9 to 100) kHz 100 kHz to 50 MHz 50 MHz to 1 GHz (1 to 2) GHz (2 to 4) GHz (4 to 6) GHz (6 to 12) GHz (12 to 18) GHz 0.48 % 0.60 % 0.59 % 0.60 % 0.62 % 0.63 % 0.81 % 1.7 % Tegam Feedthrough standard RF Power – Generate & Measure 1 mW (9 to 100) kHz 100 kHz to 50 MHz 50 MHz 50 MHz to 1 GHz (1 to 2) GHz (2 to 4) GHz (4 to 6) GHz (6 to 12) GHz (12 to 18) GHz 0.48 % 0.60 % 0.59 % 0.59 % 0.60 % 0.62 % 0.63 % 0.81 % 1.7 % Tegam Feedthrough standard
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2626.01) Revised 03/13/2025 Page 12 of 17 Parameter/Range Frequency CMC2, 5, 6 (±) Comments RF Power – Generate & Measure (cont) (0.1 to 10) W (10 to 100) W (100 to 1000) W 1700 W 700 W 1700 Watts 100 kHz to 100 MHz 100 MHz to 1 GHz (1 to 6) GHz 100 kHz to 100 MHz 100 MHz to 1 GHz (1 to 6) GHz 100 kHz to 100 MHz 100 MHz to 1 GHz (1 to 6) GHz 250 kHz to 5 MHz (10 to 15) MHz (25 to 30) MHz (35 to 65) MHz (95 to 105) MHz (150 to 170) MHz 250 kHz to 5 MHz (10 to 15) MHz (25 to 30) MHz (35 to 65) MHz (95 to 105) MHz (150 to 170) MHz 0.33 to 0.5 MHz 0.82 to 1.3 MHz 1.8 to 2.8 MHz 10 to 15 MHz 23 to 30 MHz 30 to 45 MHz 45 to 72 MHz 1.5 % 1.7 % 1.7 % 1.6 % 1.8 % 1.8 % 1.7 % 1.8 % 1.8 % 0.41 % 0.41 % 0.41 % 0.41 % 0.41 % 0.41 % 0.42 % 0.42 % 0.42 % 0.42 % 0.42 % 0.42 % 0.21 % 0.21 % 0.21 % 0.21 % 0.21 % 0.21 % 0.21 % Directional coupler & N8482A Directional Coupler & N8482H Bird 6080 calorimeter, Yokogawa WT3000 power analyzer Bird 6080 calorimeter, Yokogawa WT3000 power analyzer Bird 6085b calorimeter, Yokogawa WT3000 power analyzer
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2626.01) Revised 03/13/2025 Page 13 of 17 Parameter/Range Frequency CMC2, 6 (±) Comments RF Attenuation – Measure Magnitude: (0 to 10) dB (11 to 20) dB (21 to 30) dB (31 to 40) dB (41 to 50) dB (51 to 60) dB Phase: 0 to 180° 0 to 180° 100 kHz to 100 MHz 100 MHz to 1 GHz (1 to 8.5) GHz 100 kHz to 100 MHz 100 MHz to 1 GHz (1 to 8.5) GHz 100 kHz to 100 MHz 100 MHz to 1 GHz (1 to 8.5) GHz 100 kHz to 100 MHz 100 MHz to 1 GHz (1 to 8.5) GHz 100 kHz to 100 MHz 100 MHz to 1 GHz (1 to 8.5) GHz 100 kHz to 100 MHz 100 MHz to 1 GHz (1 to 8.5) GHz 100 kHz to 8.5 GHz 100 kHz to 8.5 GHz 0.023 dB 0.040 dB 0.031 dB 0.026 dB 0.039 dB 0.033 dB 0.029 dB 0.038 dB 0.037 dB 0.034 dB 0.043 dB 0.041 dB 0.040 dB 0.047 dB 0.047 dB 0.064 dB 0.067 dB 0.064 dB 180° UPh = arcsin(UMag/|Γ|) x 180°⁄π Rohde & Schwarz ZNB8, Keysight 85032F If U Mag ≥ |Γ |, If UMag < |Γ |, where: Γ: reflection magnitude UMag: magnitude uncertainty in linear units UPh: phase uncertainty in degrees
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2626.01) Revised 03/13/2025 Page 14 of 17 Parameter/Range Frequency CMC2, 6 (±) Comments RF Reflection Coefficient – Measure Magnitude, Linear: 0.0 to 0.2 >0.2 to 1 Phase: 0 to 180° 0 to 180° 100 kHz to 2 GHz (2 to 3) GHz (3 to 6) GHz (6 to 8.5) GHz 100 kHz to 2 GHz (2 to 3) GHz (3 to 6) GHz (6 to 8.5) GHz 100 kHz to 8.5 GHz 100 kHz to 8.5 GHz 0.0042 0.0058 0.010 0.013 0.0044 0.0062 0.0095 0.012 180° U Ph = arcsin(UMag/|Γ|) x 180°⁄π Rohde & Schwarz ZNB8, Keysight 85032F If U Mag ≥|Γ |, If U Mag < |Γ |, where: Γ: reflection magnitude UMag: magnitude uncertainty in linear units U Ph: phase uncertainty in degrees Relative Power – Measure 100 kHz to 18 GHz (0 to >-10) dB (-10 to >-20) dB (-20 to >-30) dB (-30 to >-40) dB (-40 to >-50) dB (-50 to >-60) dB (-60 to >-70) dB (-70 to >-80) dB (-80 to >-90) dB (-90 to >-100) dB (-100 to >-110) dB (-110 to >-120) dB (-120 to -127) dB 0.032 dB 0.034 dB 0.061 dB 0.062 dB 0.046 dB 0.059 dB 0.12 dB 0.11 dB 0.19 dB 0.19 dB 0.2 dB 0.2 dB 0.24 dB N5531S Measuring Receiver
15--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2626.01) Revised 03/13/2025 Page 15 of 17 Parameter/Range Frequency CMC2, 6 (±) Comments Amplitude Modulation– Measure Depth (20 to 99) % Rate: 50 Hz to 100 kHz 100 kHz to 10 MHz 10 MHz to 3 GHz 3 GHz to 18 GHz 0.87 % 0.58 % 1.7 % N5531S Measuring Receiver Frequency Modulation– Measure Deviation 200 Hz to 400 kHz, 1 kHz Modulation Rate 250 kHz to 10 MHz 10 MHz to 6.6 GHz 6.6 GHz to 18 GHz 1.2 % 1.7 % 2.9 % N5531S Measuring Receiver Phase Modulation– Measure 1 kHz Modulation Rate >0.7 radians >2 radians 100 kHz to 6.6 GHz 6.6 GHz to 18 GHz 1.2 % 1.2 % N5531S Measuring Receiver Harmonics & Subharmonics 3 Hz to 1.5 GHz 1.5 GHz to 3 GHz 3 GHz to 3.3 GHz 3.3 GHz to 6.6 GHz 6.6 GHz to 13.25 GHz 0.63 dB 1.8 dB 2.5 dB 2.9 dB 3.3 dB E4440A Spectrum Analyzer
20 to 99 %
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2626.01) Revised 03/13/2025 Page 16 of 17 III. Mechanical Parameter/Equipment Range CMC2, 6 (±) Comments Torque wrenches (0.5 to 1) lbf·in (1 to 5) lbf·in (5 to 10) lbf·in (10 to 50) lbf·in (25 to 50) lbf·in (50 to 250) lbf·in 3.5 % 3.3 % 2.2 % 1.9 % 1.3 % 0.9 % Torque Mate PTT-2000 & BMX sensors IV. Thermodynamics Parameter/Equipment Range CMC2, 6 (±) Comments Temperature – Measure & Measuring Equipment (18 to 28) °C 0.53 °C Rotronic HC2-S Humidity – Measure & Measuring Equipment 33 % RH 75 % RH (10 to 90) % RH 2.7 % RH 2.6 % RH 2.6 % RH Rotronic HC2-S V. Time & Frequency Parameter/Range Frequency CMC2, 6 (±) Comments Frequency – Measure & Measuring Equipment 10 Hz to 15 GHz 80 pHz/Hz + 0.74 µHz Agilent 53230A counter, 910R GPS receiver, RF / function generator Frequency – Time Base 10 MHz 3.5 x 10-12 Hz/Hz Wavetek 910R GPS receiver ____________________________________________ 1 This laboratory offers commercial calibration service.
17

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 2626.01) Revised 03/13/2025 Page 17 of 17 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 The measurands stated are generated with the Fluke 5720A series of instruments . This capability is suitable for the calibration of the devices intended to measure the stated measurand in the ranges indicated. CMC are expressed as either a specific value that covers the full range or as a fraction of the reading plus a fixed floor specification. 4 The measurands stated are measured with the Agilent 3458A. This capability is suitable for the calibration of the devices intended to generate the measurand in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a combination of the fraction of the reading/output plus a range specification. 5 In the statement of CMC, uncertainties expressed as a percent are to be read as percent of reading unless otherwise indicated. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 7 This scope meets A2LA’s P112 Flexible Scope Policy.
18ISO/IEC 17025:20 17; ISO-ILAC- IAF Communiqué dated April 2017; IEC 17025; ANSI/NCSL Z540-1-1994 and R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

30303 Aurora Rd., Solon, OH, 44139, US

41.39661, -81.46349

Open in Maps