Bird Service Center
30303 Aurora Rd., 44139, Solon, OH, United States
Visit website- Scope lines
- 18
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 18 scope lines.
A2LA certificate 2626.01 · 18 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ISO/IEC 17025:2017; IEC 17025; ANSI/NCSL Z540-1-1994 BIRD SERVICE CENTER 30303 | - | See scope document |
| 2 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2626.01) Revised 03/13/2025 Page 2 of 17
Parameter/Range
Range
CMC2, 3, 4, 5, 6 (±)
Comments
DC Resistance –
Generate
(1.2 to 12) Ω
(12 to 120) Ω
120 Ω to 1.2 kΩ
(1.2 to 12) kΩ
(12 to 120) kΩ
120 kΩ to 1.2 MΩ
(1.2 to 12) MΩ
(12 to 120) MΩ
120 MΩ to 1.2 GΩ
23 µΩ/Ω + 1 mΩ
19 µΩ/Ω + 1 mΩ
23 µΩ/Ω + 2 mΩ
45 µΩ/Ω + 20 mΩ
31 µΩ/Ω + 200 mΩ
41 µΩ/Ω + 2 Ω
48 µΩ/Ω + 30 Ω
0.36 mΩ/Ω + 2.5 kΩ
0.95 mΩ/Ω + 100 kΩ
Fluke 5560A
DC Resistance –
Measure
(0 to 10) Ω
(10 to 100) Ω
100 Ω to 1 kΩ
(1 to 10) kΩ
(10 to 100) kΩ
100 kΩ to 1 MΩ
(1 to 10) MΩ
(10 to 100) MΩ
100 MΩ to 1 GΩ
30 µΩ/Ω + 0.14 mΩ
29 µΩ/Ω + 1.4 mΩ
22 µΩ/Ω + 1.4 mΩ
22 µΩ/Ω + 14 mΩ
22 µΩ/Ω + 0.14 Ω
28 µΩ/Ω + 8.0 Ω
0.012 % + 0.18 kΩ
0.024 % + 1.8 kΩ
1.3 % + 18 kΩ
Agilent 3458A, opt 002 (2-
year specifications)
DC Current – Generate
(0 to 220) µA
220 µA to 2.2 mA
(2.2 to 22) mA
(22 to 220) mA
220 mA to 2.2 A
(2.2 to 11) A
(1.2 to 3.1) A
(3.1 to 12) A
(12 to 30.2) A
41 µA/A + 6.0 nA
37 µA/A + 7.0 nA
39 µA/A + 40 nA
49 µA/A + 0.70 µA
86 µA/A + 12 µA
0.37 mA/A + 0.48 mA
0.23 mA/A + 0.15 mA
0.23 mA/A + 0.25 mA
0.8 mA/A + 0.5 mA
Fluke 5720A & Fluke
5725A
Fluke 5560A
DC Current – Measure
(1 to 10) µA
(10 to 100) µA
100 µA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
39 µA/A + 0.14 nA
38 µA/A + 1.2 nA
38 µA/A + 9.0 nA
42 µA/A + 90 nA
57 µA/A + 0.90 µA
0.14 mA/A + 18 µA
Agilent 3458A, opt 002 (2-
year specifications)
DC Power – Generate
(1 to 600) W
(>600 to 5000) W
0.013 %
0.027 %
Fluke 5560A | ||
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2626.01) Revised 03/13/2025 Page 3 of 17
Parameter/Range
Frequency
CMC2, 3, 4, 5, 6 (±)
Comments
AC Voltage – Generate
(0 to 2.2) mV
(2.2 to 22) mV
(22 to 220) mV
220 mV to 2.2 V
(2.2 to 22) V
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
0.072 % + 4.0 µV
0.12 % + 4.0 µV
0.051 % + 4.0 µV
0.12 % + 4.0 µV
0.095 % + 5.0 µV
0.16 % + 10 µV
0.24 % + 20 µV
0.39 % + 20 µV
0.029 % + 20 µV
0.019 % + 20 µV
0.011 % + 20 µV
0.031 % + 20 µV
0.079 % + 20 µV
0.11 % + 20 µV
0.14 % + 20 µV
0.31 % + 20 µV
0.024 % + 20 µV
0.0099 % + 20 µV
0.0083 % + 20 µV
0.022 % + 20 µV
0.047 % + 20 µV
0.091 % + 20 µV
0.14 % + 20 µV
0.29 % + 20 µV
0.024 % + 20 µV
0.0092 % + 20 µV
0.0047 % + 20 µV
0.0077 % + 20 µV
0.011 % + 20 µV
0.026 % + 20 µV
0.10 % + 20 µV
0.18 % + 20 µV
0.024 % + 20 µV
0.0093 % + 20 µV
0.0048 % + 20 µV
0.0077 % + 20 µV
0.010 % + 20 µV
0.029 % + 20 µV
0.10 % + 20 µV
0.17 % + 20 µV
Fluke 5720A | ||
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2626.01) Revised 03/13/2025 Page 4 of 17
Parameter/Range
Frequency
CMC2, 3, 4, 5, 6 (±)
Comments
AC Voltage – Generate
(cont)
(22 to 220) V
(220 to 1100) V
(220 to 750) V
(15 to 17) V
(28 to 32) V
(56 to 64) V
(110 to 128) V
(13 to 180) V
(25 to 360) V
(75 to 1008) V
(1.2 to 12) mV
(12 to 120) mV
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(300 to 500) kHz
500 kHz to 1 MHz
(15 to 50) Hz
50 Hz to 1 kHz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 30) kHz
(30 to 50) kHz
(50 to 100) kHz
(45 to 65) Hz
(45 to 65) Hz
(45 to 65) Hz
(45 to 65) Hz
(45 to 65) Hz
(45 to 65) Hz
(45 to 65) Hz
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
0.024 % + 20 µV
0.0096 % + 20 µV
0.0064 % + 20 µV
0.0092 % + 20 µV
0.017 % + 20 µV
0.093 % + 20 µV
0.44 % + 20 µV
0.83 % + 20 µV
0.030 % + 20 µV
0.0078 % + 20 µV
0.012 % + 20 µV
0.018 % + 20 µV
0.061 % + 20 µV
0.063 % + 20 µV
0.23 % + 20 µV
0.0051 %
0.0052 %
0.0059 %
0.0056 %
0.0053 % + 1.6 mV
0.0067 % + 3.2 mV
0.007 % + 10 mV
0.2 % + 7 µV
0.071 % + 7 µV
0.027 % + 6 µV
0.03 % + 6 µV
0.12 % + 15 µV
0.62 % + 30 µV
0.19 % + 7 µV
0.068 % + 7 µV
0.011 % + 6 µV
0.027 % + 8 µV
0.062 % + 20 µV
0.16 % + 30 µV
Fluke 5720A
Where V*F ≤2.2*10
7
V*Hz
Fluke 6105A
Fluke 5560A | ||
| 5 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2626.01) Revised 03/13/2025 Page 5 of 17
Parameter/Range
Frequency
CMC2, 3, 4, 5, 6 (±)
Comments
AC Voltage – Generate
(cont)
120 mV to 1.2 V
(1.2 to 12) V
(12 to 120) V
(12 to 120) V
(120 to 330) V
(330 to 1020) V
(3 to 5) Hz
(5 to 10) Hz
(10 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(3 to 5) Hz
(5 to 10) Hz
(10 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 500) kHz
(3 to 5) Hz
(5 to 10) Hz
(10 to 40) Hz
40 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 20 kHz
(20 to 50) kHz
(50 to 100) kHz
(3 to 5) Hz
(5 to 10) Hz
10 Hz to 10 kHz
0.19 % + 75 µV
0.068 % + 70 µV
0.011 % + 60 µV
0.011 % + 8 µV
0.023 % + 14 µV
0.054 % + 40 µV
0.15 % + 80 µV
0.19 % + 0.75 mV
0.068 % + 0.75 mV
0.011 % + 0.35 mV
0.011 % + 50 µV
0.023 % + 50 µV
0.055 % + 0.13 mV
0.16 % + 0.6 mV
0.19 % + 7.5 mV
0.068 % + 7.5 mV
0.012 % + 3.5 mV
0.011 % + 0.5 mV
0.023 % + 0.5 mV
0.054 % + 1.3 mV
0.13 % + 20 mV
0.19 % + 75 mV
0.069 % + 75 mV
0.018 % + 8 mV
0.048 % + 8 mV
0.17 % + 13 mV
0.19 % + 75 mV
0.068 % + 75 mV
0.013 % + 80 mV
Fluke 5560A
AC Voltage – Measure
(0 to 10) mV
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
0.056 % + 13 µV
0.037 % + 11 µV
0.056 % + 11 µV
0.16 % + 11 µV
0.59 % + 11 µV
4.6 % + 12 µV
Agilent 3458A, opt 002
(2-year specifications) | ||
| 6 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2626.01) Revised 03/13/2025 Page 6 of 17
Parameter/Range
Frequency
CMC2, 3, 4, 5, 6 (±)
Comments
AC Voltage – Measure
cont.
(10 to 100) mV
100 mV to 1 V
(1 to 10) V
(10 to 100) V
(100 to 1000) V
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 2) MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(100 to 300) kHz
300 kHz to 1 MHz
(1 to 40) Hz
40 Hz to 1 kHz
(1 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
0.013 % + 5.1 µV
0.013 % + 2.8 µV
0.021 % + 2.8 µV
0.040 % + 2.8 µV
0.097 % + 2.8 µV
0.35 % + 12 µV
1.2 % + 12 µV
1.7 % + 12 µV
0.013 % + 51 µV
0.013 % + 28 µV
0.021 % + 28 µV
0.039 % + 28 µV
0.097 % + 28 µV
0.35 % + 0.12 mV
1.2 % + 0.12 mV
1.7 % + 0.12 mV
0.013 % + 0.51 mV
0.013 % + 0.28 mV
0.021 % + 0.28 mV
0.039 % + 0.28 mV
0.097 % + 0.28 mV
0.35 % + 1.2 mV
1.2 % + 1.2 mV
1.7 % + 1.2 mV
0.028 % + 5.1 mV
0.028 % + 2.8 mV
0.028 % + 2.8 mV
0.045 % + 2.8 mV
0.14 % + 2.8 mV
0.47 % + 12 mV
1.7 % + 12 mV
0.051 % + 51 mV
0.051 % + 28 mV
0.074 % + 28 mV
0.14 % + 28 mV
0.35 % + 28 mV
Agilent 3458A, opt 002
(2-year specifications) | ||
| 7 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2626.01) Revised 03/13/2025 Page 7 of 17
Parameter/Range
Frequency
CMC2, 3, 4, 5, 6 (±)
Comments
AC Current – Generate
(0 to 220) µA
220 µA to 2.2 mA
(2.2 to 22) mA
(22 to 220) mA
220 mA to 2.2 A
(2.2 to 11) A
(0.2 to 0.5) A
(0.4 to 1) A
(0.8 to 2) A
(2 to 5) A
(4 to 10) A
(12 to 120) µA
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(10 to 20) Hz
(20 to 40) Hz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
20 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
40 Hz to 1 kHz
(1 to 5) kHz
(5 to 10) kHz
(45 to 65) Hz
(45 to 65) Hz
(45 to 65) Hz
(45 to 65) Hz
(45 to 65) Hz
3 Hz to 5 kHz
(5 to 10) kHz
(10 to 30) kHz
0.026 % + 16 nA
0.017 % + 10 nA
0.014 % + 8.0 nA
0.033 % + 12 nA
0.11 % + 65 nA
0.026 % + 40 nA
0.017 % + 35 nA
0.013 % + 35 nA
0.022 % + 0.11 µA
0.11 % + 0.65 µA
0.026 % + 0.4 µA
0.017 % + 0.35 µA
0.013 % + 0.35 µA
0.021 % + 0.55 µA
0.11 % + 5.0 µA
0.026 % + 4.0 µA
0.017 % + 3.5 µA
0.014 % + 2.5 µA
0.022 % + 3.5 µA
0.11 % + 10 µA
0.027 % + 35 µA
0.048 % + 80 µA
0.71 % + 0.16 mA
0.049 % + 0.17 mA
0.097 % + 0.38 mA
0.36 % + 0.75 mA
0.0093 % + 3.0 µA
0.012 % + 6.0 µA
0.015 % + 12 µA
0.018 % + 30 µA
0.022 % + 60 µA
0.025 % + 10 nA
0.12 % + 40 nA
0.39 % + 1 µA
Fluke 5720A & Fluke
5725A
Fluke 6105A
Fluke 5560A | ||
| 8 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2626.01) Revised 03/13/2025 Page 8 of 17
Parameter/Range
Frequency
CMC2, 3, 4, 5, 6 (±)
Comments
AC Current – Generate
(cont)
120 µA to 1.2 mA
(1.2 to 12) mA
(12 to 120) mA
(12 to 120) mA
120 mA to 1.2 A
(1.2 to 3.1) A
(3.1 to 12) A
(12 to 30.2) A
3 Hz to 5 kHz
(5 to 10) kHz
(10 to 30) kHz
3 Hz to 5 kHz
(5 to 10) kHz
(10 to 30) kHz
(3 to 45) Hz
45 Hz to 1 kHz
1 kHz to 5 kHz
5 kHz to 10 kHz
10 kHz to 30 kHz
(3 to 45) Hz
45 Hz to 1 kHz
1 kHz to 5 kHz
5 kHz to 10 kHz
10 kHz to 30 kHz
(3 to 45) Hz
45 Hz to 1 kHz
1 kHz to 5 kHz
5 kHz to 10 kHz
(3 to 45) Hz
45 Hz to 1 kHz
1 kHz to 5 kHz
5 kHz to 10 kHz
(3 to 45) Hz
45 Hz to 1 kHz
1 kHz to 5 kHz
0.021 % + 0.1 µA
0.12 % + 0.1 µA
0.39 % + 5 µA
0.021 % + 1 µA
0.12 % + 1 µA
0.39 % + 10 µA
0.022 % + 10 µA
0.015 % + 5 µA
0.022 % + 8 µA
0.12 % + 10 µA
0.39 % + 0.1 mA
0.019 % + 0.1 mA
0.019 % + 50 µA
0.019 % + 80 µA
0.19 % + 0.3 mA
0.39 % + 0.3 mA
0.029 % + 0.5 mA
0.023 % + 0.3 mA
0.03 % + 0.3 mA
0.2 % + 0.5 mA
0.029 % + 1 mA
0.023 % + 0.5 mA
0.03 % + 0.8 mA
0.2 % + 1 mA
0.078 % + 10 mA
0.054 % + 8 mA
0.39 % + 8 mA
Fluke 5560A
AC Current – Measure
(0 to 100) µA
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
0.47 % + 35 nA
0.18 % + 35 nA
0.079 % + 35 nA
0.079 % + 35 nA
Agilent 3458A, opt 002
(2-year specifications) | ||
| 9 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2626.01) Revised 03/13/2025 Page 9 of 17
Parameter/Range
Frequency
CMC2, 5, 6 (±)
Comments
AC Current – Measure
(cont)
100 µA to 1 mA
(1 to 10) mA
(10 to 100) mA
100 mA to 1 A
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
(50 to 100) kHz
(10 to 20) Hz
(20 to 45) Hz
(45 to 100) Hz
100 Hz to 5 kHz
(5 to 20) kHz
(20 to 50) kHz
0.47 % + 0.23 µA
0.18 % + 0.23 µA
0.079 % + 0.23 µA
0.044 % + 0.23 µA
0.079 % + 0.23 µA
0.47 % + 0.46 µA
0.64 % + 1.7 µA
0.47 % + 2.3 µA
0.18 % + 2.3 µA
0.079 % + 2.3 µA
0.044 % + 2.3 µA
0.079 % + 2.3 µA
0.47 % + 4.6 µA
0.64 % + 17 µA
0.47 % + 23 µA
0.18 % + 23 µA
0.079 % + 23 µA
0.044 % + 23 µA
0.079 % + 23 µA
0.47 % + 46 µA
0.64 % + 0.17 mA
0.47 % + 0.23 mA
0.19 % + 0.23 mA
0.10 % + 0.23 mA
0.13 % + 0.23 mA
0.36 % + 0.23 mA
1.2 % + 0.46 mA
Agilent 3458A, opt 002
(2-year specifications)
AC Power – Generate
PF = 1
(1 to 300) W
(>300 to 1000) W
(>1000 to 3500) W
45 to 65 Hz
45 to 65 Hz
45 to 65 Hz
77 µW/W
91 µW/W
0.10 mW/W
Fluke 6105A | ||
| 10 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2626.01) Revised 03/13/2025 Page 10 of 17
Parameter/Range
Frequency
CMC2, 5, 6 (±)
Comments
AC Power – Measure
PF = 1
(1 to 60) W
(60 to 200) W
(200 to 750) W
(750 to 3500) W
(45 to 66) Hz
(45 to 66) Hz
(45 to 66) Hz
(45 to 66) Hz
0.055 %
0.051 %
0.049 %
0.050 %
Yokogawa WT3000E
precision power
analyzer
Capacitance – Generate
(0.10 to 1.2) nF
(1.2 to 12) nF
(12 to 120) nF
120 nF to 1.2 µF
(1.2 to 12) µF
(12 to 120) µF
120 µF to 1.2 mF
(1.2 to 12) mF
(12 to 120) mF
0.18 % + 2 pF
0.18 % + 5 pF
0.18 % + 30 pF
0.18 % + 0.3 nF
0.16 % + 3 nF
0.17 % + 23 nF
0.25 % + 0.25 µF
0.25 % + 3 µF
0.42 % + 30 µF
Fluke 5560A
Oscilloscopes –
Amplitude Square
Wave
Leveled Sine Wave
Amplitude
Time Marker
Into 50 Ω
Into 1 MΩ
5 mVp-p to 5.5 Vp-p
50 kHz (reference)
50 kHz to 10 MHz
(10 to 600) MHz
5 mVp-p to 3.5 Vp-p,
600 MHz to 1.1 GHz
80 ms
0.26 % + 40 µV
0.47 % + 40 µV
2.9 % + 100 µV
2.7 % + 100 µV
3.4 % + 100 µV
3.9 % + 100 µV
0.23 µs
Fluke 5560A/1G
Electrical Calibration of
Thermocouples –
Generate & Measure
Type J
(-200 to -100) °C
(-100 to -30) °C
(-30 to 150) °C
(150 to 760) °C
(760 to 1200) °C
0.42 °C
0.32 °C
0.18 °C
0.17 °C
0.16 °C
Fluke 5560A | ||
| 11 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2626.01) Revised 03/13/2025 Page 11 of 17
Parameter/Range
Frequency
CMC2, 5, 6 (±)
Comments
Electrical Calibration of
Thermocouples –
Generate & Measure
cont.
Type K
Type T
Type U
(-200 to -100) °C
(-100 to -25) °C
(-25 to 120) °C
(120 to 1000) °C
(1000 to 1372) °C
(-250 to -150) °C
(-150 to 0) °C
(0 to 120) °C
(120 to 400) °C
(-200 to 0) °C
(0 to 600) °C
0.69 °C
0.59 °C
0.54 °C
0.88 °C
1.4 °C
0.80 °C
0.60 °C
0.54 °C
0.87 °C
0.47 °C
0.13 °C
Fluke 5560A
II. Electrical – RF/Microwave
Parameter/Range
Frequency
CMC2, 5, 6 (±)
Comments
RF Power – 1 mW
Calibration Factor
(9 to 100) kHz
100 kHz to 50 MHz
50 MHz to 1 GHz
(1 to 2) GHz
(2 to 4) GHz
(4 to 6) GHz
(6 to 12) GHz
(12 to 18) GHz
0.48 %
0.60 %
0.59 %
0.60 %
0.62 %
0.63 %
0.81 %
1.7 %
Tegam Feedthrough
standard
RF Power – Generate
& Measure
1 mW
(9 to 100) kHz
100 kHz to 50 MHz
50 MHz
50 MHz to 1 GHz
(1 to 2) GHz
(2 to 4) GHz
(4 to 6) GHz
(6 to 12) GHz
(12 to 18) GHz
0.48 %
0.60 %
0.59 %
0.59 %
0.60 %
0.62 %
0.63 %
0.81 %
1.7 %
Tegam Feedthrough
standard | ||
| 12 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2626.01) Revised 03/13/2025 Page 12 of 17
Parameter/Range
Frequency
CMC2, 5, 6 (±)
Comments
RF Power – Generate
& Measure (cont)
(0.1 to 10) W
(10 to 100) W
(100 to 1000) W
1700 W
700 W
1700 Watts
100 kHz to 100 MHz
100 MHz to 1 GHz
(1 to 6) GHz
100 kHz to 100 MHz
100 MHz to 1 GHz
(1 to 6) GHz
100 kHz to 100 MHz
100 MHz to 1 GHz
(1 to 6) GHz
250 kHz to 5 MHz
(10 to 15) MHz
(25 to 30) MHz
(35 to 65) MHz
(95 to 105) MHz
(150 to 170) MHz
250 kHz to 5 MHz
(10 to 15) MHz
(25 to 30) MHz
(35 to 65) MHz
(95 to 105) MHz
(150 to 170) MHz
0.33 to 0.5 MHz
0.82 to 1.3 MHz
1.8 to 2.8 MHz
10 to 15 MHz
23 to 30 MHz
30 to 45 MHz
45 to 72 MHz
1.5 %
1.7 %
1.7 %
1.6 %
1.8 %
1.8 %
1.7 %
1.8 %
1.8 %
0.41 %
0.41 %
0.41 %
0.41 %
0.41 %
0.41 %
0.42 %
0.42 %
0.42 %
0.42 %
0.42 %
0.42 %
0.21 %
0.21 %
0.21 %
0.21 %
0.21 %
0.21 %
0.21 %
Directional coupler &
N8482A
Directional Coupler &
N8482H
Bird 6080 calorimeter,
Yokogawa WT3000
power analyzer
Bird 6080 calorimeter,
Yokogawa WT3000
power analyzer
Bird 6085b calorimeter,
Yokogawa WT3000
power analyzer | ||
| 13 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2626.01) Revised 03/13/2025 Page 13 of 17
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
RF Attenuation –
Measure
Magnitude:
(0 to 10) dB
(11 to 20) dB
(21 to 30) dB
(31 to 40) dB
(41 to 50) dB
(51 to 60) dB
Phase:
0 to 180°
0 to 180°
100 kHz to 100 MHz
100 MHz to 1 GHz
(1 to 8.5) GHz
100 kHz to 100 MHz
100 MHz to 1 GHz
(1 to 8.5) GHz
100 kHz to 100 MHz
100 MHz to 1 GHz
(1 to 8.5) GHz
100 kHz to 100 MHz
100 MHz to 1 GHz
(1 to 8.5) GHz
100 kHz to 100 MHz
100 MHz to 1 GHz
(1 to 8.5) GHz
100 kHz to 100 MHz
100 MHz to 1 GHz
(1 to 8.5) GHz
100 kHz to 8.5 GHz
100 kHz to 8.5 GHz
0.023 dB
0.040 dB
0.031 dB
0.026 dB
0.039 dB
0.033 dB
0.029 dB
0.038 dB
0.037 dB
0.034 dB
0.043 dB
0.041 dB
0.040 dB
0.047 dB
0.047 dB
0.064 dB
0.067 dB
0.064 dB
180°
UPh = arcsin(UMag/|Γ|)
x 180°⁄π
Rohde & Schwarz
ZNB8, Keysight
85032F
If U
Mag ≥ |Γ |,
If UMag < |Γ |, where:
Γ: reflection magnitude
UMag: magnitude
uncertainty in linear
units
UPh: phase uncertainty
in degrees | ||
| 14 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2626.01) Revised 03/13/2025 Page 14 of 17
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
RF Reflection
Coefficient – Measure
Magnitude, Linear:
0.0 to 0.2
>0.2 to 1
Phase:
0 to 180°
0 to 180°
100 kHz to 2 GHz
(2 to 3) GHz
(3 to 6) GHz
(6 to 8.5) GHz
100 kHz to 2 GHz
(2 to 3) GHz
(3 to 6) GHz
(6 to 8.5) GHz
100 kHz to 8.5 GHz
100 kHz to 8.5 GHz
0.0042
0.0058
0.010
0.013
0.0044
0.0062
0.0095
0.012
180°
U
Ph = arcsin(UMag/|Γ|)
x 180°⁄π
Rohde & Schwarz
ZNB8, Keysight
85032F
If U
Mag ≥|Γ |,
If U
Mag < |Γ |, where:
Γ: reflection magnitude
UMag: magnitude
uncertainty in linear
units
U
Ph: phase uncertainty
in degrees
Relative Power –
Measure
100 kHz to 18 GHz
(0 to >-10) dB
(-10 to >-20) dB
(-20 to >-30) dB
(-30 to >-40) dB
(-40 to >-50) dB
(-50 to >-60) dB
(-60 to >-70) dB
(-70 to >-80) dB
(-80 to >-90) dB
(-90 to >-100) dB
(-100 to >-110) dB
(-110 to >-120) dB
(-120 to -127) dB
0.032 dB
0.034 dB
0.061 dB
0.062 dB
0.046 dB
0.059 dB
0.12 dB
0.11 dB
0.19 dB
0.19 dB
0.2 dB
0.2 dB
0.24 dB
N5531S Measuring
Receiver | ||
| 15 | - | -Show page textExtracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2626.01) Revised 03/13/2025 Page 15 of 17
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
Amplitude
Modulation– Measure
Depth
(20 to 99) %
Rate: 50 Hz to 100 kHz
100 kHz to 10 MHz
10 MHz to 3 GHz
3 GHz to 18 GHz
0.87 %
0.58 %
1.7 %
N5531S Measuring
Receiver
Frequency Modulation–
Measure
Deviation 200 Hz to
400 kHz, 1 kHz
Modulation Rate
250 kHz to 10 MHz
10 MHz to 6.6 GHz
6.6 GHz to 18 GHz
1.2 %
1.7 %
2.9 %
N5531S Measuring
Receiver
Phase Modulation–
Measure
1 kHz Modulation Rate
>0.7 radians
>2 radians
100 kHz to 6.6 GHz
6.6 GHz to 18 GHz
1.2 %
1.2 %
N5531S Measuring
Receiver
Harmonics &
Subharmonics
3 Hz to 1.5 GHz
1.5 GHz to 3 GHz
3 GHz to 3.3 GHz
3.3 GHz to 6.6 GHz
6.6 GHz to 13.25 GHz
0.63 dB
1.8 dB
2.5 dB
2.9 dB
3.3 dB
E4440A Spectrum
Analyzer | 20 to 99 % |
| 16 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2626.01) Revised 03/13/2025 Page 16 of 17
III. Mechanical
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Torque wrenches
(0.5 to 1) lbf·in
(1 to 5) lbf·in
(5 to 10) lbf·in
(10 to 50) lbf·in
(25 to 50) lbf·in
(50 to 250) lbf·in
3.5 %
3.3 %
2.2 %
1.9 %
1.3 %
0.9 %
Torque Mate PTT-2000
& BMX sensors
IV. Thermodynamics
Parameter/Equipment
Range
CMC2, 6 (±)
Comments
Temperature – Measure
& Measuring
Equipment
(18 to 28) °C
0.53 °C
Rotronic HC2-S
Humidity – Measure &
Measuring Equipment
33 % RH
75 % RH
(10 to 90) % RH
2.7 % RH
2.6 % RH
2.6 % RH
Rotronic HC2-S
V. Time & Frequency
Parameter/Range
Frequency
CMC2, 6 (±)
Comments
Frequency – Measure
& Measuring
Equipment
10 Hz to 15 GHz
80 pHz/Hz + 0.74 µHz
Agilent 53230A
counter, 910R GPS
receiver, RF / function
generator
Frequency – Time Base
10 MHz
3.5 x 10-12 Hz/Hz
Wavetek 910R GPS
receiver
____________________________________________
1 This laboratory offers commercial calibration service. | ||
| 17 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2626.01) Revised 03/13/2025 Page 17 of 17
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 The measurands stated are generated with the Fluke 5720A series of instruments . This capability is
suitable for the calibration of the devices intended to measure the stated measurand in the ranges
indicated. CMC are expressed as either a specific value that covers the full range or as a fraction of the
reading plus a fixed floor specification.
4 The measurands stated are measured with the Agilent 3458A. This capability is suitable for the calibration
of the devices intended to generate the measurand in the ranges indicated. CMC’s are expressed as either
a specific value that covers the full range or as a combination of the fraction of the reading/output plus a
range specification.
5 In the statement of CMC, uncertainties expressed as a percent are to be read as percent of reading unless
otherwise indicated.
6 The type of instrument or material being calibrated is defined by the parameter. This indicates the
laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated
for the listed measurement parameter.
7 This scope meets A2LA’s P112 Flexible Scope Policy. | ||
| 18 | ISO/IEC 17025:20 17; ISO-ILAC- IAF Communiqué dated April 2017; IEC 17025; ANSI/NCSL Z540-1-1994 and R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.