Registers refreshed 2026-11-20.See refresh dates
France

LES PRÉLEVEURS INDÉPENDANTS

POLE D'ASPACH RUE DE LA STATION, 68700, ASPACH-LE-BAS, France

Visit website
COFRAC 1-5749ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Accredited standards
15
COFRAC certificate
1
Site in our directory
1
COFRAC accredited scope

What this lab is accredited for

Our reading of the COFRAC scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 15 standard numbers and the 8 official names we hold. When no standard matches, it searches the method text of every scope line.

ISO6
ISO 5667-9Water quality - Sampling - Part 9: Guidance on sampling from marine watersExclusion

Limits written next to it

ISO 5667-9 (hors échant

Exclusion. Written next to it on line 4 of COFRAC certificate 1-5749.

ISO 7027-1Water quality - Determination of turbidity - Part 1: Quantitative methods
ISO 7027-2Water quality - Determination of turbidity - Part 2: Semi-quantitative methods for the assessment of transparency of waters
ISO 7393-2Water quality - Determination of free chlorine and total chlorine - Part 2: Colorimetric method using N,N-dialkyl-1,4-phenylenediamine, for routine control purposes
ISO 10523Water quality - Determination of pH
ISO 17289Water quality - Determination of dissolved oxygen - Optical sensor method
FD5
FD T90-523-4
FD T 90-520Water quality - Technical sampling guide for the sanitary monitoring of water
FD T 90-522
FD T 90-523-1
FD T 90-523-2
Other standards4
EN 27888Water quality - Determination of electrical conductivity
NF X 31-615
T 90-521
T 90-523-3

Read from the COFRAC scope document we downloaded on 2026-02-12. Register refreshed 2026-11-20.

Scope as published by COFRAC

5 lines
COFRAC

ISO/IEC 17025

Active

1-5749

The scope document we hold says it is valid until 2028-04-30.

View scope

Accredited scope, certificate 1-5749

LineMethodMatrixRange
1NF EN ISO/IEC 17025WATER QUALITY-
2

Extracted from the scope document; tables may not line up. View scope for the original.

LAB FORM 37 – Révision 10 – applicable au 1er juillet 2025 Page 3/6 Section Laboratoires ANNEXE TECHNIQUE à l’attestation N° 1-5749 rév. 12 L’accréditation concerne les prestations réalisées par : Les Préleveurs Indépendants POLE D'ASPACH RUE DE LA STATION 68700 ASPACH-LE-BAS Dans son unité : - Echantillonnage et essai sur site Elle porte sur : voir pages suivantes
3FD T 90-520; FD T 90-521; FD T 90-523-1; FD T 90-523-4; FD T 90-523-3; NF X 31-615Mineral water-
4FD T 90-523-2; ISO 5667-9; MOP-19-PRE; FD T 90-522; MOP-22-PREWaste water-
5NF EN 27888; NF EN ISO 10523; NF ISO 17289; NF EN ISO 7393-2; Unesco (1984). L’échelle de salinité pratique de 1978 et l’équation internationale de l’eau de mer de 1980. Unesco Tech pap. Mar. Sci., 36, 25p.; NF EN ISO 7027-1; NF EN ISO 7027-2Surface water-

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

POLE D'ASPACH RUE DE LA STATION, ASPACH-LE-BAS, 68700, FR

47.76278, 7.15297

Open in Maps

Accreditation data refreshed from the COFRAC register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the COFRAC entry linked above.