cdf Schallschutz, Dieter Friedemann
Alte Dresdner Straße 54, 01108, Dresden, Germany
- Accredited standards
- 7
- DAKKS certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 7 standard numbers and the 0 official names we hold. When no standard matches, it searches the method text of every scope line.
DIN 4150-1
DIN 4150-2
DIN 4150-3
DIN 45680
DIN 45681
IEC 61400-11
VDI 2058 Blatt 1:1985-09
TA Lärm 1968-07; VDI 2058 Blatt 1:1985-09; DIN 4150-1 2001-06; DIN 4150-2 1999-06; DIN 4150-3 2016-12; LAI-Erschütterungs-LL 2018-03; AVwV Baulärm 1970-08
16. BImSchV; 18. BImSchV; LAI -Freizeitlärm -RL; DIN 45680; DIN 45681; DIN EN 61400 -11
Read from the scope as published by DAKKS. Register refreshed 2026-11-06.
Scope as published by DAKKS
3 lines
ISO/IEC 17025
ActiveD-PL-19426-01-00
Accredited scope, certificate D-PL-19426-01-00
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018; TA Lärm | Geräuschen; Erschütterungen | - |
| 2 | TA Lärm 1968-07; VDI 2058 Blatt 1:1985-09; DIN 4150-1 2001-06; DIN 4150-2 1999-06; DIN 4150-3 2016-12; LAI-Erschütterungs-LL 2018-03; AVwV Baulärm 1970-08 | - | - |
| 3 | 16. BImSchV; 18. BImSchV; LAI -Freizeitlärm -RL; DIN 45680; DIN 45681; DIN EN 61400 -11 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Germany
- Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen Leipzig mbH - MFPA LeipzigLeipzig · ~95 kmDAKKSShares 1 accredited test methodVDI 2058 Blatt 1:1985-09
- TÜV NORD Umweltschutz GmbH & Co. KGHamburg · ~377 kmDAKKSShares 1 accredited test methodVDI 2058 Blatt 1:1985-09
- Müller-BBM Industry Solutions GmbH Prüflaboratorium für Schall und Schwingungen, Elektromagnetische Felder und Licht, Immissionsschutz und GefahrstoffePlanegg · ~378 kmDAKKSShares 1 accredited test methodVDI 2058 Blatt 1:1985-09
- TÜV Technische Überwachung Hessen GmbH Abteilung UT-F2Frankfurt · ~384 kmDAKKSShares 1 accredited test methodVDI 2058 Blatt 1:1985-09
- Moeller Operating EngineeringItzehoe · ~428 kmDAKKSShares 1 accredited test methodVDI 2058 Blatt 1:1985-09
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.