LABORATOIRE NORD SERVICES (LNS)
61 RUE DU FAUBOURG DES POSTES, 59000, LILLE, France
Visit website- Accredited standards
- 4
- COFRAC certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the COFRAC scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 4 standard numbers and the 1 official name we hold. When no standard matches, it searches the method text of every scope line.
FD X46-033
ISO 16000-7Indoor air - Part 7: Sampling strategy for determination of airborne asbestos fibre concentrations
NF X43-269
NF X 43-050 (2021)
NF EN ISO 16000-7; FD X 46-033; NF X 43-050 (2021); NF X 43-269 (2017)
NF EN ISO 16000-7; FD X 46-033; NF X 43-050 (2021)
NF X 43-050 (2021); NF X 43-269 - Annexe K (2017)
NF X 43-050 (2021); HSG 248 - Annexe 2; NF X 43-050 (parties utiles de la norme)
Read from the COFRAC scope document we downloaded on 2026-02-12. Register refreshed 2026-11-20.
Scope as published by COFRAC
5 lines
ISO/IEC 17025
Active1-5570
The scope document we hold says it is valid until 2027-11-30.
Accredited scope, certificate 1-5570
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | NF EN ISO/IEC 17025 | ASBESTOS | - |
| 2 | NF X 43-050 (2021); NF X 43-269 - Annexe K (2017) | Indoor air | - |
| 3 | NF X 43-050 (2021); HSG 248 - Annexe 2; NF X 43-050 (parties utiles de la norme) | Air ambiant (Matériaux ou produits manufacturés contenant de l’amiante délibérément ajouté); Matériaux et produits manufacturés susceptibles de contenir de l’amiante délibérément ajouté : • Plâtres; • Cellulose; • Ciment / Carbonates; • Polymères; • Hydrocarbonés | - |
| 4 | NF EN ISO 16000-7; FD X 46-033; NF X 43-050 (2021); NF X 43-269 (2017) | Indoor air | - |
| 5 | NF EN ISO 16000-7; FD X 46-033; NF X 43-050 (2021) | Air | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in France
- CEAPIC : CENTRE D'EXPERTISE ET D'ACCOMPAGNEMENT EN POLLUANTS DES INDUSTRIES ET DES CONSTRUCTIONSSOISY SOUS MONTMORENCY · ~189 kmCOFRACShares 4 accredited methods and materialsEN ISO 16000-7NF X 43-050 (2021)Air
- ACEPECHERBOURG-EN-COTENTIN · ~349 kmCOFRACShares 4 accredited methods and materialsEN ISO 16000-7NF X 43-050 (2021)Air
- CICEA - OCE (OUEST CONTRÔLE ENVIRONNEMENT)ARNAGE · ~364 kmCOFRACShares 4 accredited methods and materialsEN ISO 16000-7NF X 43-050 (2021)Air
- INSTITUT TECHNIQUE DES GAZ ET DE L'AIR - ITGA - SITE DE SAINT ETIENNESAINT ETIENNE · ~584 kmCOFRACShares 4 accredited methods and materialsEN ISO 16000-7NF X 43-050 (2021)Air
- DIAG CONSULT ENVIRONNEMENTLA CHAPELLE D'ARMENTIERES · ~12 kmCOFRACShares 3 accredited methods and materialsEN ISO 16000-7AirIndoor air
Accreditation data refreshed from the COFRAC register on .