IFM Prover USA, Inc. Calibration Laboratory

15 Great Valley Parkway, 19355, Malvern, PA, United States

Visit website
A2LA 3416.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
3
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 3 scope lines.

A2LA certificate 3416.01 · 3 lines

LineMethodMatrixRange
1

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3416.01) 05/01/2025 Page 1 of 2 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 IFM PROVER USA, INC. CALIBRATION LABORATORY 15 Great Valley Parkway Malvern, PA 19355 Peter Breh Phone: 484 321 4285 CALIBRATION Valid To: June 30, 2027 Certificate Number: 3416.01 In recognition of the successful completion of the A2LA evaluation process (including an assessment of the organization’s compliance with R205 – A2LA’s Calibration Program Requirements), accreditation is granted to this laboratory to perform the following calibrations 1, 3: I. Electrical – DC/Low Frequency Parameter/Equipment Range CMC2, 4 (±) Comments Resistance – Measure (For Calibration of Temperature Transducers) (0 to 100) Ω (0 to 1000) Ω 0.10 K 0.10 K Comparison / Ametek DTI-100 and STS-100 probes / Agilent 3458A DC Current – Measure (For Calibration of Temperature Transducers) (4 to 20) mA 0.10 K Comparison / Ametek DTI-100 and STS-100 probes / Agilent 3458A DC Voltage – Measure (For Calibration of Temperature Transducers) (0 to 10) V 0.10 K Comparison / Ametek DTI-100 and STS-100 probes / Agilent 3458A
2--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3416.01) 05/01/2025 Page 2 of 2 II. Thermodynamics Parameter/Equipment Range CMC2 (±) Comments RTD (With Integral Display) (-20 to 200) °C 0.10 K Comparison / Ametek DTI-100 and STS-100 probes _________________________________ 1 This laboratory does not offer commercial calibration service. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMC’s represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 This scope meets A2LA’s P112 Flexible Scope Policy. 4 The stated measured values are determined using the indicated instrument (see comments). The capability is suitable for the calibration of the devices intended to measure the parameter value in the ranges indicated, CMCs are expressed as a specific value that covers the full range
-20 to 200 °C
3

Extracted from the scope document; tables may not line up. View scope for the original.

For the calibrations to which this accreditation applies, please refer to the laboratory’s Calibration Scope of Accreditation. Accredited Laboratory A2LA has accredited IFM PROVER USA, INC CALIBRATION LABORATORY Malvern, PA for technical competence in the field of Calibration This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This laboratory also meets the requirements of R205 – Specific Requirements: Calibration Laboratory Accreditation Program. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 1st day of May 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 3416.01 Valid to June 30, 2027

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.