Registers refreshed 2026-11-08.See refresh dates
United States

Robert Bosch

38000 Hills Tech Dr., 48331, Farmington Hills, MI, United States

Visit website
A2LA 3305.04A2LA 3305.05ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Scope lines
25
A2LA certificates
2
Sites in our directory
2
A2LA accredited scope

What this lab is accredited for

We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 25 scope lines.

A2LA certificate 3305.04 · 25 lines

LineMethodMatrixRange
1-Steel
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 3305.04) Revised 02/24/2026 Page 1 of 24 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 ROBERT BOSCH LLC 38000 Hills Tech Drive Farmington Hills, MI 48331 Christopher Milhan Phone: 248-207-2979 CALIBRATION Valid To: March 31, 2026 Certificate Number: 3305.04 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following calibrations 1, 7: I. Dimensional Parameter/Equipment Range CMC2, 4, 6 (±) Comments Angle – Measuring Equipment Alu or Reinforced Plastic Unreinforced Plastic Steel Ceramic Carbon Fiber Up to 90° of Arc Up to 360° of Arc 0.2 % + 0.018° of Arc 4.1 arcsec + (250 arcsec / L) 14 arcsec + (250 arcsec / L) 1.9 arcsec + (250 arcsec / L) 4.1 arcsec + (250 arcsec / L) 4.1 arcsec + (250 arcsec / L) Digi-Pas dual axis precision digital level Zeiss Prismo ultra coordinate measuring machine (CMM) Micrometers & Calipers (Inside & Outside Only) < 1.0 mm (1.0 to 609) mm < 0.04 in (0.04 to 24) in (0.050 + 2.6L) µm + 0.6R (0.033 + 2.6L) µm + 0.6R (2.0 + 0.11L) µin + 0.6R (1.3 + 2.8L) µin + 0.6R Gage blocks (Grade 0) Height Gages Up to 24 in (2.5 + 3.2L) µin + 0.6R Long gage blocks
to 90 ° of Arc
2-Steel
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 3305.04) Revised 02/24/2026 Page 2 of 24 II. Dimensional Testing8 Parameter/Equipment Range CMC2, 4 (±) Comments Length 2D & 3D, Contact Alu or Reinforced Plastic Unreinforced Plastic Steel Ceramic Carbon Fiber Up to 1700 mm 1.2 µm + (0.020 µm/mm x L) 1.2 μm + (0.067 μm/mm ∙ 𝐿𝐿) 1.2 μm + (0.0093 μm/mm ∙ 𝐿𝐿) 1.2 μm + (0.0064 μm/mm ∙ 𝐿𝐿) 2.2 μm + (0.0022 μm/mm ∙ 𝐿𝐿) Zeiss Prismo Ultra coordinate measuring machine (CMM) Length 2D & 3D, Optical Alu or Reinforced Plastic Steel Unreinforced Plastic Up to 400 mm 4.6µm + (0.0014 µm/mm ∙ L) 4.6 μm + (0.0063 μm/mm ∙ 𝐿𝐿) 4.6 μm + (0.057 μm/mm ∙ 𝐿𝐿) Zeiss O-Inspect coordinate measuring machine (CMM) III. Electrical – DC/Low Frequency Parameter/Equipment Frequency CMC2, 5 (±) Comments AC Voltage3 – Generate (0.22 to 2.2) mV (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz 1.5 % + 27 µV 0.82 % + 21 µV 0.62 % + 26 µV 1.0 % + 20 µV 0.53 % + 15 µV 0.67 % + 17 µV 0.22 % + 15 µV 0.45 % + 18 µV Multifunction calibrator
to 1700 mm
3

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 3305.04) Revised 02/24/2026 Page 3 of 24 Parameter/Equipment Frequency CMC2, 5 (±) Comments AC Voltage3– Generate (cont) (2.2 to 22) mV (22 to 220) mV (0.22 to 2.2) V (2.2 to 22) V (10 to 20) Hz (20 to 40) Hz 40Hz to 20kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40Hz to 20kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40Hz to 20kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40Hz to 20kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz 0.011 % + 15 µV 0.017 % + 4 µV 0.024 % + 0.4 µV 0.000 63 % + 4 µV 0.0069 % + 5 µV 0.019 % + 20 µV 0.25 % + 15 µV -0.022 % + 63 µV 0.011 % + 130 µV 0.0056 % + 7 µV 0.0025 % + 7 µV 0.0025 % + 7 µV 0.0013 % + 17 µV 0.022 % + 20 µV 0.011 % + 13 µV 0.011 % + 430 µV 0.0056 % + 1300 µV 0.0043 % + 51 µV 0.0041 % + 8 µV 0.0043 % + 10 µV 0.0043 % + 30 µV 0.011 % + 80 µV 0.034 % + 520 µV 0.17 % + 730 µV 0.062 % + 21 mV 0.0084 % + 150 µV 0.0056 % + 50 µV 0.0063 % + 100 µV 0.0046 % + 200 µV 0.062 % + 17 µV 0.058 % + 4.3 mV 0.12 % + 12mV Fluke 5730A
4

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 3305.04) Revised 02/24/2026 Page 4 of 24 Parameter/Equipment Frequency CMC2, 5 (±) Comments AC Voltage3– Generate (cont) (22 to 220) V (220 to 1100) V (10 to 20) Hz (20 to 40) Hz 40Hz to 20kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1MHz (15 to 50) Hz 50 Hz to 1 kHz 0.011 % + 120 mV 0.043 % + 1.5 mV 0.009 % + 0.6 mV 0.011 % + 1 mV 0.0091 % + 2.5 mV 0.073 % + 0.5 mV 0.16 % + 0.5 mV 0.65 % + 1.0 mV 0.92 % + 1.8 V 0.0035 % + 3.5 mV Multifunction calibrator AC Voltage3 – Measure (0 to 10) mV (10 to 100) mV 100 mV to 1 V (1 to 10) V (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 1000) kHz 0.005 % + 1.1 μV 0.015 % + 1.1 μV 0.13 % + 1.1 μV 0.81 % + 1.1 μV 0.0038 % + 0.38 μV 0.0028 % + 3.1 μV 0.0063 % + -0.4 μV 0.028 % + 0.2 µV 0.089 % + -1.4 µV 0.000 11 % + 0.048 μV 0.000 13 % + 0.042 μV 0.000 43 % + 0.024 μV 0.000 11 % + 0.023 μV 0.000 17 % + 0.097 μV 0.000 13 % + 0.002 mV 0.068 % + 0.73 mV 0.0025 % + 0.98 mV 0.000 12 % + 0.64 mV 0.0045 % + 0.51 mV 0.044 % + 0.33 mV 0.46 % + 4.2 mV 2.4 % + 17 mV HP 3458A, option HFL
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 3305.04) Revised 02/24/2026 Page 5 of 24 Parameter/Equipment Frequency CMC2, 4, 5 (±) Comments AC Voltage3 – Measure (cont.) (10 to 100) V (100 to 700) V 700 V to 6 kV 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 60 Hz 0.018 % + 1.2 mV 0.0059 % + 1.1 mV 0.013 % + 0.61 mV 0.019 % + 0.96 mV 0.0011 % + 17 mV 0.038 % + 0.011 V 0.06 % + 0.057 V 0.05 % + 0.041 V 1.0 % HP 3458A, option HFL Fluke 80K-6 w/DMM AC Current3– Generate (0 to 220) µA 220 μA to 2.2 mA (2.2 to 22) mA (22 to 220) mA (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.004 % + 0.016 µA 0.0035 % + 0.010 µA 0.004 % + 0.008 µA 0.023 % + 0.012 µA 0.005 % + 0.065 µA 0.021 % + 0.04 µA 0.024 % + 0.035 µA 0.0043 % + 0.04 µA 0.0025 % + 0.011 µA -0.006 % + 0.065 µA 0.018 % + 0.4 µA 0.0033 % + 0.35 µA 0.0043 % + 0.35 µA 0.0033 % + 0.55 µA 0.002 % + 0.11 µA 0.022 % + 4 µA 0.0053 % + 3.5 µA 0.0078 % + 2.5 µA 0.0027 % + 3.5 µA 0.018 % + 10 µA Multifunction calibrator
6

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 3305.04) Revised 02/24/2026 Page 6 of 24 Parameter/Equipment Frequency CMC2, 5 (±) Comments AC Current3– Generate (cont) 220 mA to 2.2 A 200 mA to 2 A (2 to 20) A 20 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 65) Hz (65 to 300) Hz 300 Hz to 1 kHz (1 to 3) kHz (3 to 6) kHz (10 to 65) Hz (65 to 300) Hz 300 Hz to 1 kHz (1 to 3) kHz (3 to 6) kHz 0.058 % + 35 µA 0.018 % + 80 µA 0.14 % + 160 µA 0.0063 % + 180 µA 0.063 % + 74 µA 0.17 % + 160 µA 0.05 % + 1.6 mA 0.18 % + 2.6 mA -0.049 % + 13 mA 0.026 % + 2.7 mA 0.1 % + 1.0 mA 0.1 % + 10 mA -0.11 % + 30 mA HP 3458A, option HFL Fluke 5730A / 52120A AC Current3–Measure (0 to 100) µA 100 µA to 1 mA (1 to 10) mA (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz 0.023 % + 0.03 µA 0.023 % + 0.03 µA 0.063 % + 0.03 µA 0.023 % + 0.03 µA 0.07 % + 0.2 µA 0.07 % + 0.2 µA 0.071 % + 0.2 µA 0.048 % + 0.4 µA 0.048 % + 0.4 µA 0.063 % + 0.2 µA 0.059 % + 0.2 µA 0.059 % + 0.2 µA 0.059 % + 0.2 µA 0.059 % + 0.2 µA 0.053 % + 0.4 µA HP 3458A, option HFL
7

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 3305.04) Revised 02/24/2026 Page 7 of 24 Parameter/Equipment Frequency CMC2, 5 (±) Comments AC Current3–Measure (cont) (10 to 100) mA 100 mA to 1 A (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz 0.093 % + 0.2 µA 0.093 % + 0.2 µA 0.093 % + 0.2 µA 0.093 % + 0.2 µA 0.093 % + 0.2 A 0.092 % + 0.4 µA 0.11 % + 20 µA 0.11 % + 20 µA 0.11 % + 20 µA 0.11 % + 20 µA 0.11 % + 20 µA 0.11 % + 40 µA HP 3458A, option HFL Parameter/Equipment Range CMC2, 4, 5 (±) Comments DC Voltage3 – Generate (0 to 220) mV 220 mV to 2.2 V (2.2 to 11) V (11 to 22) V (22 to 220) V (220 to 1100) V 0.0010 % + 0.4 µV 0.0033 % + 0.7 µV 0.000 32 % + 2.5 µV 0.000 22 % + 4.0 µV 0.000 16 % + 40 µV 0.0011 % + 0.4 mV Fluke 5730A DC Voltage3 – Measure High Voltage (0 to 100) mV 100 mV to 1 V (1.0 to 10) V (10 to 100) V (100 to 1000) V Up to 6 kV (6 to 20) kV (20 to 35) kV (35 to 40) kV 0.000 90 % + 300 nV -0.028 % + 260 µV 0.000 74 % - 1.9 µV 0.000 74 % + 6.8 µV 0.0038 % - 0.007 V 1.0 % 1.2 % 1.1 % 2.3 % HP 3458A, option HFL Fluke 80K-6 w/DMM Fluke 80K-40 w/DMM
8--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 3305.04) Revised 02/24/2026 Page 8 of 24 Parameter/Equipment Range CMC2, 4, 5 (±) Comments DC Current3 – Generate (0 to 220) µA 220 µA to 2.2 mA (2.2 to 22) mA (22 to 220) mA 220 mA to 2.2 A (0 to 2) A (2 to 20) A (20 to 100) A 0.0040 % + 0.006 µA 0.0014 % + 0.007 µA 0.000 95 % + 0.04 µA 0.0014 % + 0.07 µA 0.0025 % + 12 µA 0.004 % + 100 µA 0.0045 % + 1 mA 0.007 % + 6 mA Fluke 5730A Fluke 52120A DC Current3 – Measure (10 to 100) µA 100 µA to 1 mA (1 to 10) mA (10 to 100) mA 100 mA to 1 A (1 to 10) A (10 to 100) A (100 to 300) A 0.0022 % + 0.8 nA 0.000 19 % + 0.1 nA 0.0035 % + 33 nA 0.12 % + 57 nA 0.005 % + 140 µA 0.0048 % + 82 µA 0.0081 % + 0.39 mA 0.006 % + 0.5 mA HP 3458A, option HFL HP 3458A w/ guideline 9211A Resistance3 – Generate 1 Ω 1.9 Ω 10 Ω 19 Ω 100 Ω 190 Ω 1 kΩ 1.9 kΩ 10 kΩ 19 kΩ 100 kΩ 190 kΩ 1 MΩ 1.9 MΩ 10 MΩ 19 MΩ 100 MΩ 0.0037 % 0.0027 % 0.0021 % 0.0027 % 0.000 94 % 0.000 84 % 0.000 59 % 0.000 49 % 0.019 % 0.000 68 % 0.000 83 % 0.000 74 % 0.0017 % 0.0027 % 0.0055 % 0.011 % 0.015 % Multifunction calibrator
to 100 MΩ
9

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 3305.04) Revised 02/24/2026 Page 9 of 24 Parameter/Equipment Range CMC2, 5 (±) Comments Resistance3 – Measure (0 to 10) Ω (10 to 100) Ω 100 Ω to 1 kΩ (1 to 10) kΩ (10 to 100) kΩ 100 kΩ to 1 MΩ (1 to 10) MΩ (10 to 100) MΩ 100 MΩ to 1 GΩ 0.0003 % + 110 µΩ 0.0012 % + 500 µΩ 0.0003 % + 110 µΩ 0.19 % + 0.008 Ω 0.001 % + 0.011 Ω 0.0013 % + 0.58 Ω 0.018 % + 130 Ω 0.071 % + 540 Ω 0.68 % + 7.7 kΩ HP 3458A, option HFL Electrical Simulation3 – Thermocouple Indication Devices Type J Type K Type T (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.32 °C 0.27 °C 0.27 °C 0.27 °C 0.29 °C 0.35 °C 0.27 °C 0.26 °C 0.31 °C 0.39 °C 0.55 °C 0.30 °C 0.27 °C 0.26 °C Fluke 552XA Electrical Simulation3 – RTD Indicating Devices Pt 385, 100 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C 0.039 °C 0.039 °C 0.054 °C 0.07 °C 0.078 °C 0.093 °C 0.18 °C Fluke 552XA
10

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 3305.04) Revised 02/24/2026 Page 10 of 24 Parameter Frequency CMC2, 4, 5 (±) Comments Capacitance3 – Generate (0.19 to 0.3999) nF (0.4 to 1.1) nF (1.1 to 3.3) nF (3.3 to 11) nF (11 to 33) nF (33 to 110) nF (110 to 330) nF (0.33 to 1.1) μF (1.1 to 3.3) μF (3.3 to 11) μF (11 to 33) μF (33 to 110) μF (110 to 330) μF (0.33 to 1.1) mF 10 Hz to 10 kHz 10 Hz to 10 kHz 10 Hz to 3 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 to 1 kHz (10 to 600) Hz (10 to 300) Hz (10 to 150) Hz (10 to 120) Hz (10 to 80) Hz (10 to 50) Hz (0 to 20) Hz 0.17 % + 1.6 pF 0.17 % + 0.38 pF 0.089 % + 0.83 pF 0.039 % + 0.003 nF 0.079 % - 1.8 pF 0.054 % + 25 pF 0.07 % + 0.04 nF 0.038 % + 0.36 nF 0.069 % + 0.02 nF 0.077 % + 0.001 µF 0.12 % + 0.0048 µF 0.087 % + 0.054 µF 0.26 % + 0.13 µF 0.83 % + 0.002 mF Fluke 552XA Oscilloscopes – Level Sine Wave Amplitude 5 mVp-p to 5.5 Vp-p Flatness (Bandwidth) 5 mV p-p to 5.5 Vp-p Time Markers Rise Time Square Wave Signal (1 kHz Input): 50 Ω Load @ 1 kHz 1 MΩ Load @ 1 kHz 50 kHz 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (600 to 1100) MHz 50 kHz to 100 MHz (100 to 300) MHz (300 to 600) MHz (600 to 1100) MHz (2 to 5) ns 10 ns (20 to 50) ns 100 ns to 20 ms 50 ms to 5 s ≥ 300 ps 1 mV to 6.6 V pk – pk 1 mV to 130 V pk – pk 2 % + 300 µV 3.6 % + 300 µV 4.2 % + 300 µV 6 % + 300 µV 7.1 % + 300 µV 1.6 % + 100 µV 2.1 % + 100 µV 4.1 % + 100 µV 5.2 % + 100 µV 2.8 µs/s 2.8 µs/s 2.8 µs/s 2.8 µs/s (25 + 1000t) µs/s 86 ps 0.14 % + 90 µV 0.15 % + 40 µV Fluke 5522A/SC1100 t = time in seconds
11OIML-See scope document
12

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 3305.04) Revised 02/24/2026 Page 12 of 24 Parameter/Equipment Range CMC2, 4, 6 (±) Comments Pressure Gauges3 – Measuring Equipment Pneumatic Hydraulic Up to 10 MPa Up to 700 kPa (-15 to 15) kPa Up to 10 000 psig Up to 500 psig 0.023 % + 4.8 kPa 0.0026 % + 0.061 kPa 0.096 % + 0.002 kPa 0.021 % + 0.88 psig 0.018 % + 0.06 psig DHI RPM4 A10M/A700 DHI RPM4 BG15S Additel ADT681-02- GP10K-PSI-N Additel ADT681-02- GP500-PSI-N Acceleration/Vibration – Measuring Equipment (5 to 9) Hz (10 to 99) Hz 100 Hz (101 to 920) Hz 921 Hz to 5 kHz (5 to 10) kHz 2.0 % 1.2 % 0.74 % 0.98 % 1.4 % 2.2 % Modal Shop 9155 V. Thermodynamics Parameter/Equipment Range CMC2, 4, 6 (±) Comments Temperature3 – Measure & Measuring Equipment (-200 to 420) °C 0.14 % + 0.14 °C Hart Scientific 1502 w/5615 PRT Relative Humidity3 – Measure & Measuring Equipment (10 to 95) % RH 0.83 % + 0.51 % RH Vaisala HMP77B
13

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 3305.04) Revised 02/24/2026 Page 13 of 24 VI. Time & Frequency Parameter/Equipment Range CMC2, 6 (±) Comments Frequency – Measuring Equipment3 10 MHz Up to 1 MHz 4.5E-11 Hz/Hz 4 µHz/Hz Fluke 910R/073 GPS receiver Fluke 5520A
14

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 3305.04) Revised 02/24/2026 Page 14 of 24 SATELLITE LABORATORY ROBERT BOSCH LLC 15000 N Haggerty Rd, Plymouth, MI 48170 Christopher Milhan Phone: 248-207-2979 CALIBRATION I. Electrical – DC/ Low Frequency Parameter/Equipment Frequency CMC2, 5 (±) Comments AC Voltage3– Generate (0.22 to 2.2) mV (2.2 to 22) mV (22 to 220) mV (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500k to 1MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz 1.5 % + 27 µV 0.82 % + 21 µV 0.62 % + 26 µV 1.0 % + 20 µV 0.53 % + 15 µV 0.67 % + 17 µV 0.22 % + 15 µV 0.45 % + 18 µV 0.011 % + 15 µV 0.017 % + 4 µV 0.024 % + 0.4 µV 0.000 63 % + 4 µV 0.0069 % + 5 µV 0.019 % + 20 µV 0.25 % + 15 µV -0.022 % + 63 µV 0.011 % + 130 µV 0.0056 % + 7 µV 0.0025 % + 7 µV 0.0025 % + 7 µV 0.0013 % + 17 µV 0.022 % + 20 µV 0.011 % + 13 µV 0.011 % + 430 µV Fluke 5730A
15

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 3305.04) Revised 02/24/2026 Page 15 of 24 Parameter/Equipment Frequency CMC2, 5 (±) Comments AC Voltage3– Generate (cont) (0.22 to 2.2) V (2.2 to 22) V (22 to 220) V (220 to 1100) V (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 20 kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 500) kHz 500 kHz to 1 MHz (15 to 50) Hz 50 Hz to 1 kHz 0.0056 % + 1300 µV 0.0043 % + 51 µV 0.0041 % + 8 µV 0.0043 % + 10 µV 0.0043 % + 30 µV 0.011 % + 80 µV 0.034 % + 520 µV 0.17 % + 730 µV 0.062 % + 21 mV 0.0084 % + 150 µV 0.0056 % + 50 µV 0.0063 % + 100 µV 0.0046 % + 200 µV 0.062 % + 17 µV 0.058 % + 4.3 mV 0.12 % + 12mV 0.011 % + 120 mV 0.043 % + 1.5 mV 0.009 % + 0.6 mV 0.011 % + 1 mV 0.0091 % + 2.5 mV 0.073 % + 0.5 mV 0.16 % + 0.5 mV 0.65 % + 1.0 mV 0.92 % + 1.8 V 0.0035 % + 3.5 mV Multifunction calibrator AC Voltage3 – Measure (0 to 10) mV (10 to 100) mV (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz 0.005 % + 1.1 μV 0.015 % + 1.1 μV 0.13 % + 1.1 μV 0.81 % + 1.1 μV 0.0038 % + 0.38 μV 0.0028 % + 3.1 μV 0.0063 % - 0.4 μV 0.028 % + 0.2 μV 0.089 % - 1.4 μV HP 3458A, option HFL
16

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 3305.04) Revised 02/24/2026 Page 16 of 24 Parameter/Equipment Frequency CMC2, 5 (±) Comments AC Voltage3 – Measure (cont) 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 700) V 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz 300 kHz to 1 MHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (300 to 1000) kHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 300) kHz (1 to 20) kHz (20 to 50) kHz (50 to 100) kHz 0.000 11 % + 0.048 μV 0.000 13 % + 0.042 μV 0.000 43 % + 0.024 μV 0.000 11 % + 0.023 μV 0.000 17 % + 0.097 μV 0.000 13 % + 0.002 mV 0.068 % + 0.73 mV 0.0025 % + 0.98 mV 0.000 12 % + 0.64 mV 0.0045 % + 0.51 mV 0.044 % + 0.33 mV 0.46 % + 4.2 mV 2.4 % + 17 mV 0.018 % + 1.2 mV 0.0059 % + 1.1 mV 0.013 % + 0.61 mV 0.019 % + 0.96 mV 0.0011 % + 17 mV 0.038 % + 0.011 V 0.06 % + 0.057 V 0.05 % + 0.041 V HP 3458A, option HFL AC Current3– Generate (0 to 220) µA 220 μA to 2.2 mA (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.004 % + 0.016 µA 0.0035 % + 0.010 µA 0.004 % + 0.008 µA 0.023 % + 0.012 µA 0.005 % + 0.065 µA 0.021 % + 0.04 µA 0.024 % + 0.035 µA 0.0043 % + 0.04 µA 0.0025 % + 0.011 µA -0.006 % + 0.065 µA Multifunction calibrator
17

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 3305.04) Revised 02/24/2026 Page 17 of 24 Parameter/Equipment Frequency CMC2, 5 (±) Comments AC Current3– Generate (cont) (2.2 to 22) mA (22 to 220) mA 220 mA to 2.2 A 200 mA to 2 A (2 to 20) A (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 20) Hz (20 to 40) Hz 40 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 20 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz (10 to 65) Hz (65 to 300) Hz 300 Hz to 1kHz (1 to 3) kHz (3 to 6) kHz (10 to 65) Hz (65 to 300) Hz 300 Hz to 1 kHz (1 to 3) kHz (3 to 6) kHz 0.018 % + 0.4 µA 0.0033 % + 0.35 µA 0.0043 % + 0.35 µA 0.0033 % + 0.55 µA 0.002 % + 0.11 µA 0.022 % + 4 µA 0.0053 % + 3.5 µA 0.0078 % + 2.5 µA 0.0027 % + 3.5 µA 0.018 % + 10 µA 0.058 % + 35 µA 0.018 % + 80 µA 0.14 % + 160 µA 0.0063 % + 180 µA 0.063 % + 74 µA 0.17 % + 160 µA 0.05 % + 1.6 mA 0.18 % + 2.6 mA -0.049 % + 13 mA 0.026 % + 2.7 mA 0.1 % + 1.0 mA 0.1 % + 10 mA -0.11 % + 30 mA Multifunction calibrator Multifunction calibrator / 52120A AC Current3–Measure (0 to 100) µA 100 µA to 1 mA (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz 0.023 % + 0.03 µA 0.023 % + 0.03 µA 0.063 % + 0.03 µA 0.023 % + 0.03 µA 0.07 % + 0.2 µA 0.07 % + 0.2 µA 0.071 % + 0.2 µA 0.048 % + 0.4 µA 0.048 % + 0.4 µA HP 3458A, option HFL
18

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 3305.04) Revised 02/24/2026 Page 18 of 24 Parameter/Equipment Frequency CMC2, 5 (±) Comments AC Current3 – Measure (cont) (1 to 10) mA (10 to 100) mA 100 mA to 1 A (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz (10 to 20) Hz (20 to 45) Hz (45 to 100) Hz 100 Hz to 5 kHz (5 to 20) kHz (20 to 50) kHz 0.063 % + 0.2 µA 0.059 % + 0.2 µA 0.059 % + 0.2 µA 0.059 % + 0.2 µA 0.059 % + 0.2 µA 0.053 % + 0.4 µA 0.093 % + 0.2 µA 0.093 % + 0.2 µA 0.093 % + 0.2 µA 0.093 % + 0.2 µA 0.093 % + 0.2 µA 0.092 % + 0.4 µA 0.11 % + 20 µA 0.11 % + 20 µA 0.11 % + 20 µA 0.11 % + 20 µA 0.11 % + 20 µA 0.11 % + 40 µA HP 3458A, option HFL Parameter/Equipment Range CMC2, 4, 5 (±) Comments DC Voltage3 – Generate (0 to 220) mV 220 mV to 2.2 V (2.2 to 11) V (11 to 22) V (22 to 220) V (220 to 1100) V 0.0010 % + 0.4 µV 0.0033 % + 0.7 µV 0.000 32 % + 2.5 µV 0.000 22 % + 4.0 µV 0.000 16 % + 40 µV 0.0011 % + 0.4 mV Multifunction calibrator DC Voltage3 – Measure Fixed Point (0 to 100) mV 100 mV to 1 V (1.0 to 10) V (10 to 100) V (100 to 1000) V (6 to 40) kV 0.000 90 % + 300 nV -0.028 % + 260 µV 0.000 74 % - 1.9 µV 0.000 74 % + 6.8 µV 0.0038 % - 0.007 V 1.6 % HP 3458A, option HFL HP 3458A & Fluke 80K-40
19

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 3305.04) Revised 02/24/2026 Page 19 of 24 Parameter/Equipment Range CMC2, 4, 5 (±) Comments DC Current3 – Generate (0 to 220) µA 220 µA to 2.2 mA (2.2 to 22) mA (22 to 220) mA 220 mA to 2.2 A (0 to 2) A (2 to 20) A (20 to 100) A 0.0040 % + 0.006 µA 0.0014 % + 0.007 µA 0.000 95 % + 0.04 µA 0.0014 % + 0.07 µA 0.0025 % + 12 µA 0.004 % + 100 µA 0.0045 % + 1mA 0.007 % + 6 mA Multifunction calibrator Fluke 52120A DC Current3 – Measure (10 to 100) µA 100 µA to 1 mA (1 to 10) mA (10 to 100) mA 100 mA to 1 A (1 to 10) A (10 to 100) A (100 to 300) A 0.0022 % + 0.8 nA 0.000 19 % + 0.1 nA 0.0035 % + 33 nA 0.12 % + 57 nA 0.005 % + 140 µA 0.0048 % + 82 µA 0.0081 % + 0.39 mA 0.006 % + 0.5 mA HP 3458A, option HFL HP 3458A w/ guideline 9211A Resistance3 – Generate 1 Ω 1.9 Ω 10 Ω 19 Ω 100 Ω 190 Ω 1 kΩ 1.9 kΩ 10 kΩ 19 kΩ 100 kΩ 190 kΩ 1 MΩ 1.9 MΩ 10 MΩ 19 MΩ 100 MΩ 0.0037 % 0.0027 % 0.0021 % 0.0027 % 0.000 94 % 0.000 84 % 0.000 59 % 0.000 49 % 0.019 % 0.000 68 % 0.000 83 % 0.000 74 % 0.0017 % 0.0027 % 0.0055 % 0.011 % 0.015 % Multifunction calibrator
20

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 3305.04) Revised 02/24/2026 Page 20 of 24 Parameter/Equipment Range CMC2, 5 (±) Comments Resistance3 – Measure (0 to 10) Ω (10 to 100) Ω 100 Ω to 1 kΩ (1 to 10) kΩ (10 to 100) kΩ 100 kΩ to 1 MΩ (1 to 10) MΩ (10 to 100) MΩ 100 MΩ to 1 GΩ 0.0003 % + 110 µΩ 0.0012 % + 500 µΩ 0.0003 % + 110 µΩ 0.19 % + 0.008 Ω 0.001 % + 0.011 Ω 0.0013 % + 0.58 Ω 0.018 % + 130 Ω 0.071 % + 540 Ω 0.68 % + 7.7 kΩ HP 3458A, option HFL Parameter/Equipment Frequency CMC2, 5 (±) Comments Capacitance3 – Generate (0.19 to 0.3999) nF (0.4 to 1.1) nF (1.1 to 3.3) nF (3.3 to 11) nF (11 to 33) nF (33 to 110) nF (110 to 330) nF (0.33 to 1.1) μF (1.1 to 3.3) μF (3.3 to 11) μF (11 to 33) μF (33 to 110) μF (110 to 330) μF (0.33 to 1.1) mF 10 Hz to 10 kHz 10 Hz to 10 kHz 10 Hz to 3 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz 10 Hz to 1 kHz (10 to 600) Hz (10 to 300) Hz (10 to 150) Hz (10 to 120) Hz (10 to 80) Hz (10 to 50) Hz (0 to 20) Hz 0.17 % + 1.6 pF 0.17 % + 0.38 pF 0.089 % + 0.83 pF 0.039 % + 0.003 nF 0.079 % - 1.8 pF 0.054 % + 25 pF 0.07 % + 0.04 nF 0.038 % + 0.36 nF 0.069 % + 0.02 nF 0.077 % + 0.001 µF 0.12 % + 0.0048 µF 0.087 % + 0.054 µF 0.26 % + 0.13 µF 0.83 % + 0.002 mF Fluke 552XA
21

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 3305.04) Revised 02/24/2026 Page 21 of 24 Parameter/Equipment Range CMC2 (±) Comments Electrical Simulation3 – Thermocouple Indication Devices Type J Type K Type T (-210 to -100) °C (-100 to -30) °C (-30 to 150) °C (150 to 760) °C (760 to 1200) °C (-200 to -100) °C (-100 to -25) °C (-25 to 120) °C (120 to 1000) °C (1000 to 1372) °C (-250 to -150) °C (-150 to 0) °C (0 to 120) °C (120 to 400) °C 0.32 °C 0.27 °C 0.27 °C 0.27 °C 0.29 °C 0.35 °C 0.27 °C 0.26 °C 0.31 °C 0.39 °C 0.55 °C 0.30 °C 0.27 °C 0.26 °C Fluke 552XA Electrical Simulation3 – RTD Indicating Devices Pt 385, 100 Ω (-200 to -80) °C (-80 to 0) °C (0 to 100) °C (100 to 300) °C (300 to 400) °C (400 to 630) °C (630 to 800) °C 0.039 °C 0.039 °C 0.054 °C 0.07 °C 0.078 °C 0.093 °C 0.18 °C Fluke 552XA
22

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 3305.04) Revised 02/24/2026 Page 22 of 24 II. Mechanical Parameter/Equipment Range CMC2, 4, 6 (±) Comments Torque3 – Tools (20 to 200) ozf‧in (5 to 50) lbf‧in (30 to 400) lbf‧in (80 to 1000) lbf‧in (25 to 250) lbf‧ft (60 to 600) lbf‧ft 0.44 % + 0.52 ozf‧in 0.9 % + 0.008 lbf‧in 0.21 % + 0.37 lbf‧in 0.52 % + 0.57 lbf‧in 0.29 % + 0.48 lbf‧ft 1.0 % + 0.5 lbf‧ft CDI 2001-O-TTP CDI 5000-ST Torque Angle3 – Torque – Tools (0 to 180)° Up to 250 lbf‧ft 0.19° Heidenhain ND280ROD 18000 03S1203 w/ Snap-On TEST180 Pressure Gauges3 – Measuring Equipment Pneumatic Hydraulic Up to 10 MPa Up to 700 kPa (-15 to 15) kPa Up to 10 000 psig Up to 500 psig 0.023 % + 4.8 kPa 0.0026 % + 0.061 kPa 0.096 % + 0.002 kPa 0.021 % + 0.88 psig 0.018 % + 0.06 psig DHI RPM4 A10M/A700 DHI RPM4 BG15S Additel ADT681-02- GP10K-PSI-N Additel ADT681-02- GP500-PSI-N
23--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 3305.04) Revised 02/24/2026 Page 23 of 24 III. Thermodynamics Parameter/Equipment Range CMC2, 4, 6 (±) Comments Temperature3 – Measuring Equipment (-200 to 420) °C 0.14 % + 0.14 °C Hart Scientific 1502 w/5615 PRT Relative Humidity3 – Measuring Equipment (10 to 95) % RH 0.83 % + 0.51 % RH Vaisala HMP77B IV. Time & Frequency Parameter/Equipment Range CMC2, 6 (±) Comments Frequency – Measuring Equipment3 Up to 1 MHz 4 µHz/Hz Fluke 5520A _________________________________________ 1 This laboratory offers non-commercial calibration and field calibration services, where noted. 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 Field calibration service is available for this calibration. Please note the actual measurement uncertainties achievable on a customer ’s site can normally be expected to be larger than the Calibration and Measurement Capability Uncertainty (CMC) found on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of calibration and for other possible adverse effects such as those caused by transportation of the calibration equipment. The usual allowance for the uncertainty introduced by the item being calibrated, (e.g., resolution) must also be considered and this, on its own, could result in the actual measurement uncertainty achievable on a customer’s site being larger than the CMC. 4 In the statement of CMC, R is the resolution of the unit under test; l is length in mm, all percentages are percent of reading unless otherwise indicated.
-200 to 420 °C
24

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert No. 3305.04) Revised 02/24/2026 Page 24 of 24 5 The stated measured values are determined using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure or generate the measured value in the ranges indicated. CMC’s are expressed as either a specific value that covers the full range or as a percent or fraction of the reading plus a fixed floor specification. 6 The type of instrument or material being calibrated is defined by the parameter. This indicates the laboratory is capable of calibrating instruments that measure or generate the values in the ranges indicated for the listed measurement parameter. 7 This scope meets A2LA’s P112 Flexible Scope Policy. 8 This laboratory meets R205 – Specific Requirements: Calibration Laboratory Accreditation Program for the types of dimensional tests listed above and is considered equivalent to that of a calibration.
25ISO/IEC 17025:2017; R205--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

38000 Hills Tech Dr., Farmington Hills, MI, 48331, US

42.48531, -83.37716

Open in Maps

Other Locations

1 other site in this organization

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.