FindTestingLabs
Registers refreshed 2026-09-25.See refresh dates
United Kingdom

Thomas Bell-Wright International

Unit 3, Hayloaders Works, Wotton Road, Brill, HP18 9UB, Aylesbury, United Kingdom

UKAS|27292ISO/IEC 17025Register refreshed 2026-09-25
Certificates
1
Scope items
8
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at Thomas Bell-Wright International?

Claim this profile to keep it accurate.

Register record

UKASRefreshed
27292Active

Certificates and scope

1
UKAS

ISO/IEC 17025

Active

27292

View scope

Accredited scope, certificate 27292

LineDisciplineMethodMatrixRange
1-ISO/IEC 17025:2017--
2Materials TestingBS EN ISO 1182:2020 BS EN ISO 1182:2010; BS EN ISO 11925-2 :2020 Lab Reaction to fire - calorific value BS EN ISO 1716 :2018 Lab Reaction to fire tests for building products excluding floorings exposed to the thermal attack by a single burning item BS EN 13823:2020; BS EN ISO 9239-1:2010; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 1182:2020 BS EN ISO 1182:2010Plastics-
3Electrical TestingBS EN 13501-1 and BS EN 13501- 2; BS 8414-1; BS 8414-2; BS 476; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2NON-LOADBEARING EXTERNAL CLADDING SYSTEMS; CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS; BUILDING CONSTRUCTION COMPONENTS AND MATERIALS; WALLS AND PARTITIONS-
4Electrical TestingBS EN 1365-1:2012 BS 476 - 21:Section 8 :1987 Corr 1:2014 ISO 834-4:2000 IS/ISO 834-4:2000 ASTM E119-24 NFPA 251:2006 UL 263 Ed 14:2022 Lab CEILINGS - Non load bearing Fire resistance BS EN 1364-2:2018 BS 476 - 22:Section 9:1987 Corr 1 :2014 ISO 834-9:2003Cor1 :2009 IS/ISO 834-9 :2003Cor1 :2009 ASTM E119-24 NFPA 251:2006 UL 263 Ed 14:2022 Lab FLOORS AND ROOFS - Load bearing Fire resistance BS EN 1365-2:2014 BS 476 - 21; BS EN 1365-3:2000 BS 476 - 21; BS 476; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 834-4:2000 IS/ISO 834-4:2000 ASTM E119-24 NFPA 251:2006 UL 263 Ed 14:2022 Lab CEILINGS - Non load bearing Fire resistance BS EN 1364-2:2018 BS 476 - 22:Section 9:1987 Corr 1 :2014 ISO 834-9:2003Cor1 :2009 IS/ISO 834-9 :2003Cor1 :2009 ASTM E119-24 NFPA 251:2006 UL 263 Ed 14:2022 Lab FLOORS AND ROOFS - Load bearing Fire resistance BS EN 1365-2:2014 BS 476 - 21WALLS and PARTITIONS - Load bearing; CEILINGS - Non load bearing; FLOORS AND ROOFS - Load bearing; BEAMS - Load bearing-
5Electrical TestingBS EN 1365-4:1999 BS 476 - 21; BS EN 1634-2:2008 Lab HORIZONTAL PROTECTIVE MEMBRANES Fire resistance BS EN 13381-1:2020 BS 476 Part 23:1987 Lab APPLIED PASSIVE PROTECTION PRODUCTS Fire resistance BS EN 13381-4:2013 Lab APPLIED REACTIVE PROTECTION PRODUCTS Fire resistance BS EN 13381-8:2013 Lab RAISED ACCESS AND HOLLOW CORE FLOORS Fire resistance BS EN 1366-6:2004 Lab WINDOW ASSEMBLIES Fire resistance UL 9 Ed 8 2020 Lab GLAZING Fire resistance BS 476 - 22:1987:Section 10 Corr 1 :2014 ISO 3009:2003 NFPA 257:2022 IS 16945:2018; BS 476; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 834-7:2000 IS/ISO 834-7:2000 ASTM E119-24 NFPA 251:2006 UL 263 Ed 14:2022COLUMNS; DOOR, SHUTTER AND OPENABLE WINDOW ASSEMBLIES; BUILDING HARDWARE; HORIZONTAL PROTECTIVE MEMBRANES; APPLIED PASSIVE PROTECTION PRODUCTS; APPLIED REACTIVE PROTECTION PRODUCTS; RAISED ACCESS AND HOLLOW CORE FLOORS; WINDOW ASSEMBLIES; GLAZING-
6Electrical TestingBS EN 1366-3:2021 ASTM E814-24 UL 1479 Ed4:2023 IS 12458:2019 Lab LINEAR JOINT SEALS Fire resistance BS EN 1366-4:2021 ISO 3008-4:2021 Lab AIR TRANSFER GRILLES Fire resistance BS EN 1364-5:2017 Lab VENTILATION DUCTS Fire resistance BS 476 Part 24:1987 Lab DAMPERS Fire resistance UL 555 Ed 7:2020; BS 476; ISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 20902-1:2018 Lab BUILDING JOINT SYSTEMS Fire resistance UL 2079 5th Edition 2024 Lab PENETRATION SEALS Fire resistance BS EN 1366-3:2021 ASTM E814-24 UL 1479 Ed4:2023 IS 12458:2019 Lab LINEAR JOINT SEALS Fire resistance BS EN 1366-4:2021 ISO 3008-4:2021 Lab AIR TRANSFER GRILLES Fire resistance BS EN 1364-5:2017 Lab VENTILATION DUCTS Fire resistance BS 476 Part 24:1987 Lab DAMPERS Fire resistance UL 555 Ed 7:2020; IEC 17025Air-
7Electrical TestingISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 1182 EN ISO 1716 EN ISO 9239-1 EN ISO 11925-2; IEC 17025Wood-
8Electrical TestingISO/IEC 17025:2017 Schedule of Accreditation issued by United Kingdom Accreditation Service 2; ISO 1182 EN ISO 1716 EN ISO 9239-1 EN ISO 11925-2; IEC 17025--

Ranges are reproduced from the accredited scope document as published. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

Unit 3, Hayloaders Works, Wotton Road, Brill, Aylesbury, HP18 9UB, GB

51.81614, -0.81304

Open in Maps

Accreditation data refreshed from the UKAS register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the UKAS entry linked above.