Bioscientia Institut für Medizinische Diagnostik GmbH Zweigniederlassung Bioscientia MVZ Mainz
Wallstraße 3 - 5, 55122, Mainz, Germany
- Accredited standards
- 12
- DAKKS certificates
- 2
- Site in our directory
- 1
What this lab is accredited for
Our reading of the DAKKS scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 12 standard numbers and the 11 official names we hold. When no standard matches, it searches the method text of every scope line.
ISO9
ISO 5667-5Water quality - Sampling - Part 5: Guidance on sampling of drinking water from treatment works and piped distribution systems
ISO 6222Water quality - Enumeration of culturable micro-organisms - Colony count by inoculation in a nutrient agar culture medium
ISO 7393-2Water quality - Determination of free chlorine and total chlorine - Part 2: Colorimetric method using N,N-dialkyl-1,4-phenylenediamine, for routine control purposes
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
ISO 9308-1Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 1: Membrane filtration method for waters with low bacterial background flora
ISO 10523Water quality - Determination of pH
ISO 11731Water quality - Enumeration of Legionella
ISO 16266Water quality - Detection and enumeration of Pseudomonas aeruginosa - Method by membrane filtration
ISO 19458Water quality - Sampling for microbiological analysis
Other standards3
19643-1
EN 1622Water quality - Determination of the threshold odour number (TON) and threshold flavour number (TFN)
EN 27888Water quality - Determination of electrical conductivity
DIN EN ISO 19458 2006-12 Wasserbeschaffenheit - Probenahme für mikrobiologische Untersuchungen UBA Empfehlung 18; DIN EN ISO 9308 -1 2017 -09 Intestinale Enterokokken DIN EN ISO 7899 -2 2000 -11; ISO 5667 -5 2011-02 Wasserbeschaffenheit - Probenahme - Teil 5: Anleitung zur Probenahme von Trinkwasser aus Aufbereitungsanlagen und Rohrnetzsystemen DIN EN ISO 19458 2006-12 Wasserbeschaffenheit - Probenahme für mikrobiologische Untersuchungen UBA Empfehlung 18; ISO 9308 -1 2017 -09 Intestinale Enterokokken DIN EN ISO 7899 -2 2000 -11; EN ISO 19458 2006-12 Wasserbeschaffenheit - Probenahme für mikrobiologische Untersuchungen UBA Empfehlung 18
DIN EN ISO 7393 -2; DIN EN ISO 6222; DIN EN ISO 16266; DIN EN ISO 9308 -1; DIN EN ISO 7899 -2
DIN EN ISO 9308 -1 2017 -09 Eisen nicht belegt Elektrische Leitfähigkeit DIN EN 27888 1993 -11 Färbung nicht belegt Geruch DIN EN 1622 2006 -10; DIN EN ISO 6222 1999 -07; DIN EN ISO 10523; DIN EN ISO 11731 2019 -03 UBA Empfehlung 18; DIN EN 1622 2006 -10
DIN EN ISO 19458; DIN EN ISO 10523; DIN EN 27888; DIN 19643-1; DIN 38404
Read from the scope as published by DAKKS. Register refreshed 2026-11-06.
Scope as published by DAKKS
8 lines
ISO/IEC 17025
ActiveD-PL-13452-05-00
Accredited scope, certificate D-PL-13452-05-00
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018 | - | - |
| 2 | DIN EN ISO/IEC 17000 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
ISO/IEC 17025
ActiveD-PL-13452-05-01
Accredited scope, certificate D-PL-13452-05-01
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | DIN EN ISO/IEC 17025:2018 | - | - |
| 2 | DIN EN ISO 19458; DIN EN ISO 10523; DIN EN 27888; DIN 19643-1; DIN 38404 | Water | - |
| 3 | DIN EN ISO 7393 -2; DIN EN ISO 6222; DIN EN ISO 16266; DIN EN ISO 9308 -1; DIN EN ISO 7899 -2 | Water | - |
| 4 | DIN EN ISO 19458 2006-12 Wasserbeschaffenheit - Probenahme für mikrobiologische Untersuchungen UBA Empfehlung 18; DIN EN ISO 9308 -1 2017 -09 Intestinale Enterokokken DIN EN ISO 7899 -2 2000 -11; ISO 5667 -5 2011-02 Wasserbeschaffenheit - Probenahme - Teil 5: Anleitung zur Probenahme von Trinkwasser aus Aufbereitungsanlagen und Rohrnetzsystemen DIN EN ISO 19458 2006-12 Wasserbeschaffenheit - Probenahme für mikrobiologische Untersuchungen UBA Empfehlung 18; ISO 9308 -1 2017 -09 Intestinale Enterokokken DIN EN ISO 7899 -2 2000 -11; EN ISO 19458 2006-12 Wasserbeschaffenheit - Probenahme für mikrobiologische Untersuchungen UBA Empfehlung 18 | Water | - |
| 5 | DIN EN ISO 9308 -1 2017 -09 Eisen nicht belegt Elektrische Leitfähigkeit DIN EN 27888 1993 -11 Färbung nicht belegt Geruch DIN EN 1622 2006 -10; DIN EN ISO 6222 1999 -07; DIN EN ISO 10523; DIN EN ISO 11731 2019 -03 UBA Empfehlung 18; DIN EN 1622 2006 -10 | Water | - |
| 6 | EN 1 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in Germany
- CAL GmbH & Co. KGDarmstadt · ~29 kmDAKKSShares 5 accredited methods and materialsEN ISO 19458EN ISO 19458 2006-12EN ISO 6222 1999-07
- Institut Kuhlmann GmbH Analytik-Zentrum LudwigshafenLudwigshafen · ~58 kmDAKKSShares 5 accredited methods and materialsEN ISO 19458EN ISO 19458 2006-12EN ISO 6222 1999-07
- ISEGA, Forschungs- und Untersuchungs-Gesellschaft mit beschränkter HaftungAschaffenburg · ~61 kmDAKKSShares 5 accredited methods and materialsEN ISO 19458EN ISO 19458 2006-12EN ISO 6222 1999-07
- Horn & Co. AnalyticsWenden · ~107 kmDAKKSShares 5 accredited methods and materialsEN ISO 19458EN ISO 19458 2006-12EN ISO 7393-2
- Verein des Hygiene-Instituts des Ruhrgebiets e.V. Hygiene-Institut des Ruhrgebiets Institut für Umwelthygiene und ToxikologieGelsenkirchen · ~186 kmDAKKSShares 5 accredited methods and materialsEN ISO 19458EN ISO 19458 2006-12EN ISO 7393-2
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.