Dorsey Metrology Calibration Laboratory
53 Oakley Street, 12601, Poughkeepsie, NY, United States
Visit website- Scope lines
- 4
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
We could not match the method references in this lab’s scope to published test standard numbers. The full scope as published is below.
Only this lab. Searches the method, matrix and range of each of the 4 scope lines.
A2LA certificate 2981.01 · 4 lines
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2981.01) Revised 12/18/2024 Page 1 of 3
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017
DORSEY METROLOGY CALIBRATION LABORATORY
53 Oakley Street
Poughkeepsie, NY 12601
Michael Sanchez Phone: 845 454 3111
CALIBRATION
Valid To: November 30, 2026 Certificate Number: 2981.01
In recognition of the successful completion of the A2LA evaluation process (including an assessment of
the organization’s compliance with A2LA’s Calibration Program Requirements), accreditation is granted
to this laboratory at the location listed to perform the following calibrations
1:
I. Dimensional
Parameter/Equipment
Range
CMC2, 4 (±)
Comments
Dial Indicator – High
Amplification (High
Resolution)
0.00002 in (0.0005 mm)
0.00005 in (0.001 mm)
0.0001 in (0.002 mm)
Up to 0.050 in
Up to 1.30 mm
27 µin (0.7 µm)
38 µin (1.0 µm)
63 µin (1.6 µm)
MET-7.2.1, calibration
tester
521-104
Dial Indicator – Traditional
(Low Resolution)
0.0001 in (0.002 mm)
0.00025 in (0.005 mm)
0.0005 in (0.01 mm)
0.001 in (0.02mm)
Up to 1 in
Up to 25.4 mm
67 µin (1.7 µm)
160 µin (4.0 µm)
290 µin (7.4 µm)
580 µin (14.7 µm)
MET-7.2.1, calibration
tester
170-101 | ||
| 2 | MET-7.2.2; MET-7.2.3; MET-7.2.4; MET-7.2.5; MET-7.2.6; MET-7.2.7 | - | to 1 in |
| 3 | Extracted from the scope document; tables may not line up. View scope for the original. (A2LA Cert. No. 2981.01) Revised 12/18/2024 Page 3 of 3
2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement
that a laboratory can achieve within its scope of accreditation when performing more or less routine
calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent
expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage
factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory
may be greater than the CMC due to the behavior of the customer’s device and to influences from the
circumstances of the specific calibration.
3 Field calibration service is available for these calibrations. Please note the actual measurement
uncertainties achievable on a customer's site can normally be expected to be larger than the CMC found
on the A2LA Scope. Allowance must be made for aspects such as the environment at the place of
calibration and for other possible adverse effects such as those caused by transportation of the calibration
equipment. The usual allowance for the uncertainty introduced by the item being calibrated, (e.g.
resolution) must also be considered and this, on its own, could result in the actual measurement
uncertainty achievable on a customer’s site being larger than the CMC.
4 In the statement of CMC, L is the numerical value of the nominal length of the device measured in inches,
and R is the resolution of the unit under test. | ||
| 4 | ISO/IEC 17025:2017; R205 | - | - |
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.