Fontana Fasteners
3281 West County Road 0 NS, 46041, Frankfort, IN, United States
Visit website- Accredited standards
- 19
- A2LA certificate
- 1
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 19 standard numbers and the 13 official names we hold. When no standard matches, it searches the method text of every scope line.
ASTM15
ASTM A370Standard Test Methods and Definitions for Mechanical Testing of Steel Products
ASTM B117Standard Practice for Operating Salt Spray (Fog) Apparatus
ASTM B568
ASTM B767
ASTM E3Standard Guide for Preparation of Metallographic Specimens
ASTM E18Standard Test Methods for Rockwell Hardness of Metallic Materials
ASTM E376Standard Practice for Measuring Coating Thickness by Magnetic-Field or Eddy Current (Electromagnetic) Testing Methods
ASTM E384Standard Test Method for Microindentation Hardness of Materials
ASTM E407Standard Practice for Microetching Metals and Alloys
ASTM E709
ASTM E1444
ASTM F606Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets
ASTM F788
ASTM F2328Standard Test Method for Determining Decarburization and Carburization in Hardened and Tempered Threaded Steel Bolts, Screws, Studs, and Nuts
ASTM F3125
ISO4
ISO 4759-1Tolerances for fasteners - Part 1: Bolts, screws, studs and nuts - Product grades A, B and C
ISO 6157-1Fasteners - Surface discontinuities - Part 1: Bolts, screws and studs for general requirements
ISO 6157-3Fasteners - Surface discontinuities - Part 3: Bolts, screws and studs for special requirements
ISO 16047Fasteners - Torque/clamp force testing
ASTM F606/F606M; ASTM E18; SAE J4294; ASTM E384; ASTM B767; ASTM A370; ISO 16047; ASTM F3125/F3125M; ASTM B568; ASTM E376; ASTM F2328; SAE J419; SAE J423; ASTM E3; ASTM E407; ASTM B117
ASTM F788; ISO 6157-1; ISO 6157-3; SAE J1234; SAE J10615; ASTM E1444; ASTM E709; ASME B1.3; FED-STD-H28/20; ISO 4759-1; MIL-STD-1205
Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.
Scope as published by A2LA
4 lines
ISO/IEC 17025
Active122.02
The scope document we hold says it was valid until 2026-05-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.
Accredited scope, certificate 122.02
| Line | Method | Matrix | Range |
|---|---|---|---|
| 1 | ASTM F606/F606M; ASTM E18; SAE J4294; ASTM E384; ASTM B767; ASTM A370; ISO 16047; ASTM F3125/F3125M; ASTM B568; ASTM E376; ASTM F2328; SAE J419; SAE J423; ASTM E3; ASTM E407; ASTM B117 | Fasteners | - |
| 2 | ASTM F788; ISO 6157-1; ISO 6157-3; SAE J1234; SAE J10615; ASTM E1444; ASTM E709; ASME B1.3; FED-STD-H28/20; ISO 4759-1; MIL-STD-1205 | - | See scope document |
| 3 | MIL-STD-1205; ASME B18.2.3.5M; ASME B18.2.9 | - | to 0.095 in |
| 4 | Extracted from the scope document; tables may not line up. View scope for the original. For the types of tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation.
Accredited Laboratory
A2LA has accredited
FONTANA FASTENERS, INC.
Frankfort, IN
for technical competence in the field of
Mechanical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017
General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates
technical competence for a defined scope and the operation of a laboratory quality management system
(refer to joint ISO-ILAC-IAF Communiqué dated April 2017).
Presented this 1st day of October 2024.
_______________________
Mr. Trace McInturff, Vice President, Accreditation Services
For the Accreditation Council
Certificate Number 0122.02
Valid to May 31, 2026 | ||
Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.
Location
Labs with overlapping accredited scope in United States
- IMR Test Labs - PortlandPortland, OR · ~2,976 kmA2LAShares 2 accredited methods and materialsASTM F606/F606MFasteners
- Element Materials Technology ChicagoGlendale Heights, IL · ~225 kmA2LAShares 1 accredited test methodASTM F606/F606M
- AFI IndustriesCarol Stream, IL · ~227 kmA2LAShares 1 accredited materialFasteners
- Chem-Plate IndustriesElk Grove Village, IL · ~227 kmA2LAShares 1 accredited materialFasteners
- National Exposure TestingSylvania, OH · ~284 kmA2LAShares 1 accredited materialFasteners
Accreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.