Registers refreshed 2026-11-08.See refresh dates
United States

Fontana Fasteners

3281 West County Road 0 NS, 46041, Frankfort, IN, United States

Visit website
A2LA 122.02ISO/IEC 17025Register refreshed 2026-11-06

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free. No lab gets your details until you choose.
Accredited standards
19
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

Our reading of the A2LA scope: each standard once, with its official name where we have checked it.

Only this lab. Searches the 19 standard numbers and the 13 official names we hold. When no standard matches, it searches the method text of every scope line.

ASTM15
ASTM A370Standard Test Methods and Definitions for Mechanical Testing of Steel Products
ASTM B117Standard Practice for Operating Salt Spray (Fog) Apparatus
ASTM B568
ASTM B767
ASTM E3Standard Guide for Preparation of Metallographic Specimens
ASTM E18Standard Test Methods for Rockwell Hardness of Metallic Materials
ASTM E376Standard Practice for Measuring Coating Thickness by Magnetic-Field or Eddy Current (Electromagnetic) Testing Methods
ASTM E384Standard Test Method for Microindentation Hardness of Materials
ASTM E407Standard Practice for Microetching Metals and Alloys
ASTM E709
ASTM E1444
ASTM F606Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets
ASTM F788
ASTM F2328Standard Test Method for Determining Decarburization and Carburization in Hardened and Tempered Threaded Steel Bolts, Screws, Studs, and Nuts
ASTM F3125
ISO4
ISO 4759-1Tolerances for fasteners - Part 1: Bolts, screws, studs and nuts - Product grades A, B and C
ISO 6157-1Fasteners - Surface discontinuities - Part 1: Bolts, screws and studs for general requirements
ISO 6157-3Fasteners - Surface discontinuities - Part 3: Bolts, screws and studs for special requirements
ISO 16047Fasteners - Torque/clamp force testing

Read from the A2LA scope document we downloaded on 2026-03-14. Register refreshed 2026-11-06.

Scope as published by A2LA

4 lines
A2LA

ISO/IEC 17025

Active

122.02

The scope document we hold says it was valid until 2026-05-31. That date has passed, so our copy may be out of date. We downloaded it from the A2LA register on 2026-03-14. Check the A2LA register for the current scope.

View scope

Accredited scope, certificate 122.02

LineMethodMatrixRange
1ASTM F606/F606M; ASTM E18; SAE J4294; ASTM E384; ASTM B767; ASTM A370; ISO 16047; ASTM F3125/F3125M; ASTM B568; ASTM E376; ASTM F2328; SAE J419; SAE J423; ASTM E3; ASTM E407; ASTM B117Fasteners-
2ASTM F788; ISO 6157-1; ISO 6157-3; SAE J1234; SAE J10615; ASTM E1444; ASTM E709; ASME B1.3; FED-STD-H28/20; ISO 4759-1; MIL-STD-1205-See scope document
3MIL-STD-1205; ASME B18.2.3.5M; ASME B18.2.9-to 0.095 in
4

Extracted from the scope document; tables may not line up. View scope for the original.

For the types of tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation. Accredited Laboratory A2LA has accredited FONTANA FASTENERS, INC. Frankfort, IN for technical competence in the field of Mechanical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this 1st day of October 2024. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 0122.02 Valid to May 31, 2026

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

3281 West County Road 0 NS, Frankfort, IN, 46041, US

40.27977, -86.51082

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.