FindTestingLabs
Registers refreshed 2026-10-18.See refresh dates
Spain

IDNEO Technologies, S.A. (Unipersonal)

Polígono Industrial Can Mitjans, s/n, 08232, Viladecavalls, Spain

ENAC|827/LE1882ISO/IEC 17025Register refreshed 2026-10-10
Certificates
1
Scope items
12
Standards
53
Locations
1

Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.

Only the laboratory you pick gets your contact details. We ask the others without them.

Contact this laboratory

No contact information available

Open ENAC register entry
Follow this lab

We will email you if this laboratory’s accreditation status or scope changes. No newsletter, only changes.

Work at IDNEO Technologies, S.A. (Unipersonal)?

Claim this profile to keep it accurate.

Register record

ENACRefreshed
827/LE1882Active

Accredited standards

53

Our reading of the ENAC scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.

IEC 61000 series

IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
As written on the certificate · Line 5 (ENAC 827/LE1882)

EN IEC 61000-3-2; EN 61000-3-3; EN 61000-4-2; EN IEC 61000-4-3; EN 61000-4-4; EN 61000-4-5; EN 61000-4-6

IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection
As written on the certificate · Line 5 (ENAC 827/LE1882)

EN IEC 61000-3-2; EN 61000-3-3; EN 61000-4-2; EN IEC 61000-4-3; EN 61000-4-4; EN 61000-4-5; EN 61000-4-6

IEC 61000-4-2Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
As written on the certificate · Line 5 (ENAC 827/LE1882)

EN IEC 61000-3-2; EN 61000-3-3; EN 61000-4-2; EN IEC 61000-4-3; EN 61000-4-4; EN 61000-4-5; EN 61000-4-6

IEC 61000-4-3Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity testCertificate says EN 61000-4-3. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 5 (ENAC 827/LE1882)

EN IEC 61000-3-2; EN 61000-3-3; EN 61000-4-2; EN IEC 61000-4-3; EN 61000-4-4; EN 61000-4-5; EN 61000-4-6

IEC 61000-4-4Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
As written on the certificate · Line 5 (ENAC 827/LE1882)

EN IEC 61000-3-2; EN 61000-3-3; EN 61000-4-2; EN IEC 61000-4-3; EN 61000-4-4; EN 61000-4-5; EN 61000-4-6

IEC 61000-4-5Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity test
As written on the certificate · Line 5 (ENAC 827/LE1882)

EN IEC 61000-3-2; EN 61000-3-3; EN 61000-4-2; EN IEC 61000-4-3; EN 61000-4-4; EN 61000-4-5; EN 61000-4-6

IEC 61000-4-6Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields
As written on the certificate · Line 5 (ENAC 827/LE1882)

EN IEC 61000-3-2; EN 61000-3-3; EN 61000-4-2; EN IEC 61000-4-3; EN 61000-4-4; EN 61000-4-5; EN 61000-4-6

IEC 61000-4-8Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity testCertificate says EN 61000-4-8. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 6 (ENAC 827/LE1882)

EN 61000-4-8; EN IEC 61000-4-11; EN 6100-4-29; EN IEC 61000-6-1; EN IEC 61000-6-2; EN IEC 61000-6-3

IEC 61000-4-11Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
As written on the certificate · Line 6 (ENAC 827/LE1882)

EN 61000-4-8; EN IEC 61000-4-11; EN 6100-4-29; EN IEC 61000-6-1; EN IEC 61000-6-2; EN IEC 61000-6-3

IEC 61000-6-1Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
As written on the certificate · Line 6 (ENAC 827/LE1882)

EN 61000-4-8; EN IEC 61000-4-11; EN 6100-4-29; EN IEC 61000-6-1; EN IEC 61000-6-2; EN IEC 61000-6-3

IEC 61000-6-2Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
As written on the certificate · Line 6 (ENAC 827/LE1882)

EN 61000-4-8; EN IEC 61000-4-11; EN 6100-4-29; EN IEC 61000-6-1; EN IEC 61000-6-2; EN IEC 61000-6-3

IEC 61000-6-3Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environmentsCertificate says EN 61000-6-3. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 6 (ENAC 827/LE1882)

EN 61000-4-8; EN IEC 61000-4-11; EN 6100-4-29; EN IEC 61000-6-1; EN IEC 61000-6-2; EN IEC 61000-6-3

IEC 61000-6-4Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments
As written on the certificate · Line 7 (ENAC 827/LE1882)

EN IEC 61000-6-4; EN IEC 61326-1; EN IEC 61326-2-6; ETSI EN 301 489-1; ETSI EN 301 489-3

IEC

IEC 60204-1Safety of machinery - Electrical equipment of machines - Part 1: General requirements
As written on the certificate · Line 4 (ENAC 827/LE1882)

EN 60204-1; EN 60335-1; EN IEC 60335-1; EN 60601-1-2; EN 60945

IEC 60335-1Household and similar electrical appliances - Safety - Part 1: General requirementsCertificate says EN 60335-1. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 4 (ENAC 827/LE1882)

EN 60204-1; EN 60335-1; EN IEC 60335-1; EN 60601-1-2; EN 60945

As written on the certificate · Line 10 (ENAC 827/LE1882)

IEC 61010-1; EN 61010-1; IEC 61010-2-081; EN 61010-2-081; IEC 61010-2-101; EN 61010-2-101; EN 60335-1

IEC 60601-1-2Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
As written on the certificate · Line 4 (ENAC 827/LE1882)

EN 60204-1; EN 60335-1; EN IEC 60335-1; EN 60601-1-2; EN 60945

IEC 60601-1-11Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment
As written on the certificate · Line 9 (ENAC 827/LE1882)

ISO 10605; ISO 16750-2; IEC 60601-1; EN 60601-1; IEC 60601-1-11; EN 60601-1-11

IEC 60945Maritime navigation and radiocommunication equipment and systems - General requirements - Methods of testing and required test results
As written on the certificate · Line 4 (ENAC 827/LE1882)

EN 60204-1; EN 60335-1; EN IEC 60335-1; EN 60601-1-2; EN 60945

IEC 61326-1Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements
As written on the certificate · Line 7 (ENAC 827/LE1882)

EN IEC 61000-6-4; EN IEC 61326-1; EN IEC 61326-2-6; ETSI EN 301 489-1; ETSI EN 301 489-3

IEC 61326-2-6Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-6: Particular requirements - In vitro diagnostic (IVD) medical electrical equipment
As written on the certificate · Line 7 (ENAC 827/LE1882)

EN IEC 61000-6-4; EN IEC 61326-1; EN IEC 61326-2-6; ETSI EN 301 489-1; ETSI EN 301 489-3

IEC 61547Equipment for general lighting purposes - EMC immunity requirementsCertificate says EN 61547. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 3 (ENAC 827/LE1882)

EN IEC 55015; EN IEC 61547; FCC CFR 47 Part 15; EN 55032; EN 55035

IEC 62233Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposureCertificate says EN 62233. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 2 (ENAC 827/LE1882)

EN 62233; EN 62479; EN 50491-5-1; EN 50491-5-2; EN 55011; EN IEC 55014-1; EN IEC 55014-2

IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements
As written on the certificate · Line 11 (ENAC 827/LE1882)

IEC 62368-1; EN IEC 62368-1

IEC 62479Assessment of the compliance of low power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
As written on the certificate · Line 2 (ENAC 827/LE1882)

EN 62233; EN 62479; EN 50491-5-1; EN 50491-5-2; EN 55011; EN IEC 55014-1; EN IEC 55014-2

CISPR

CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurementCertificate says EN 55011. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 2 (ENAC 827/LE1882)

EN 62233; EN 62479; EN 50491-5-1; EN 50491-5-2; EN 55011; EN IEC 55014-1; EN IEC 55014-2

CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: EmissionCertificate says IEC 55014-1. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 2 (ENAC 827/LE1882)

EN 62233; EN 62479; EN 50491-5-1; EN 50491-5-2; EN 55011; EN IEC 55014-1; EN IEC 55014-2

CISPR 14-2Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standardCertificate says IEC 55014-2. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 2 (ENAC 827/LE1882)

EN 62233; EN 62479; EN 50491-5-1; EN 50491-5-2; EN 55011; EN IEC 55014-1; EN IEC 55014-2

CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipmentCertificate says EN IEC 55015, IEC 55015. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 3 (ENAC 827/LE1882)

EN IEC 55015; EN IEC 61547; FCC CFR 47 Part 15; EN 55032; EN 55035

CISPR 25Vehicles, boats and internal combustion engines - Radio disturbance characteristics - Limits and methods of measurement for the protection of on-board receiversCertificate says EN 55025, IEC 55025. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 8 (ENAC 827/LE1882)

ETSI EN 301 489-17; Reglamento ECE Nº 10; EN 55025; EN IEC 55025; CISPR 25; ISO 11452-2; ISO 11452-4; ISO 11452-5; ISO7637-2; ISO7637-3; ISO11452-8; ISO11452-9

CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirementsCertificate says EN 55032. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 3 (ENAC 827/LE1882)

EN IEC 55015; EN IEC 61547; FCC CFR 47 Part 15; EN 55032; EN 55035

CISPR 35Electromagnetic compatibility of multimedia equipment - Immunity requirementsCertificate says EN 55035. Probably the same standard; not checked against the EN document.
As written on the certificate · Line 3 (ENAC 827/LE1882)

EN IEC 55015; EN IEC 61547; FCC CFR 47 Part 15; EN 55032; EN 55035

EN

EN 6100-4-29Name not checked yet
As written on the certificate · Line 6 (ENAC 827/LE1882)

EN 61000-4-8; EN IEC 61000-4-11; EN 6100-4-29; EN IEC 61000-6-1; EN IEC 61000-6-2; EN IEC 61000-6-3

EN 50121-3-2Railway applications - Electromagnetic compatibility - Part 3-2: Rolling stock - Apparatus
As written on the certificate · Line 1 (ENAC 827/LE1882)

EN 50121-3-2; EN 50121-4; EN 50130-4

EN 50121-4Railway applications - Electromagnetic compatibility - Part 4: Emission and immunity of the signalling and telecommunications apparatus
As written on the certificate · Line 1 (ENAC 827/LE1882)

EN 50121-3-2; EN 50121-4; EN 50130-4

EN 50130-4Alarm systems - Part 4: Electromagnetic compatibility - Product family standard: Immunity requirements for components of fire, intruder, hold up, CCTV, access control and social alarm systems
As written on the certificate · Line 1 (ENAC 827/LE1882)

EN 50121-3-2; EN 50121-4; EN 50130-4

EN 50491-5-1Name not checked yet
As written on the certificate · Line 2 (ENAC 827/LE1882)

EN 62233; EN 62479; EN 50491-5-1; EN 50491-5-2; EN 55011; EN IEC 55014-1; EN IEC 55014-2

EN 50491-5-2Name not checked yet
As written on the certificate · Line 2 (ENAC 827/LE1882)

EN 62233; EN 62479; EN 50491-5-1; EN 50491-5-2; EN 55011; EN IEC 55014-1; EN IEC 55014-2

ISO 11452 series

ISO 11452-2Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 2: Absorber-lined shielded enclosure
As written on the certificate · Line 8 (ENAC 827/LE1882)

ETSI EN 301 489-17; Reglamento ECE Nº 10; EN 55025; EN IEC 55025; CISPR 25; ISO 11452-2; ISO 11452-4; ISO 11452-5; ISO7637-2; ISO7637-3; ISO11452-8; ISO11452-9

ISO 11452-4Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 4: Harness excitation methods
As written on the certificate · Line 8 (ENAC 827/LE1882)

ETSI EN 301 489-17; Reglamento ECE Nº 10; EN 55025; EN IEC 55025; CISPR 25; ISO 11452-2; ISO 11452-4; ISO 11452-5; ISO7637-2; ISO7637-3; ISO11452-8; ISO11452-9

ISO 11452-5Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 5: Stripline
As written on the certificate · Line 8 (ENAC 827/LE1882)

ETSI EN 301 489-17; Reglamento ECE Nº 10; EN 55025; EN IEC 55025; CISPR 25; ISO 11452-2; ISO 11452-4; ISO 11452-5; ISO7637-2; ISO7637-3; ISO11452-8; ISO11452-9

ISO 11452-8Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 8: Immunity to magnetic fields
As written on the certificate · Line 8 (ENAC 827/LE1882)

ETSI EN 301 489-17; Reglamento ECE Nº 10; EN 55025; EN IEC 55025; CISPR 25; ISO 11452-2; ISO 11452-4; ISO 11452-5; ISO7637-2; ISO7637-3; ISO11452-8; ISO11452-9

ISO 11452-9Road vehicles - Component test methods for electrical disturbances from narrowband radiated electromagnetic energy - Part 9: Portable transmitters
As written on the certificate · Line 8 (ENAC 827/LE1882)

ETSI EN 301 489-17; Reglamento ECE Nº 10; EN 55025; EN IEC 55025; CISPR 25; ISO 11452-2; ISO 11452-4; ISO 11452-5; ISO7637-2; ISO7637-3; ISO11452-8; ISO11452-9

ISO

ISO 7637-2Road vehicles - Electrical disturbances from conduction and coupling - Part 2: Electrical transient conduction along supply lines only
As written on the certificate · Line 8 (ENAC 827/LE1882)

ETSI EN 301 489-17; Reglamento ECE Nº 10; EN 55025; EN IEC 55025; CISPR 25; ISO 11452-2; ISO 11452-4; ISO 11452-5; ISO7637-2; ISO7637-3; ISO11452-8; ISO11452-9

ISO 7637-3Road vehicles - Electrical disturbances from conduction and coupling - Part 3: Electrical transient transmission by capacitive and inductive coupling via lines other than supply lines
As written on the certificate · Line 8 (ENAC 827/LE1882)

ETSI EN 301 489-17; Reglamento ECE Nº 10; EN 55025; EN IEC 55025; CISPR 25; ISO 11452-2; ISO 11452-4; ISO 11452-5; ISO7637-2; ISO7637-3; ISO11452-8; ISO11452-9

ISO 10605Road vehicles - Test methods for electrical disturbances from electrostatic discharge
As written on the certificate · Line 9 (ENAC 827/LE1882)

ISO 10605; ISO 16750-2; IEC 60601-1; EN 60601-1; IEC 60601-1-11; EN 60601-1-11

ISO 16750-2Road vehicles - Environmental conditions and testing for electrical and electronic equipment - Part 2: Electrical loads
As written on the certificate · Line 9 (ENAC 827/LE1882)

ISO 10605; ISO 16750-2; IEC 60601-1; EN 60601-1; IEC 60601-1-11; EN 60601-1-11

ETSI

ETSI EN 301 489-1Name not checked yet
As written on the certificate · Line 7 (ENAC 827/LE1882)

EN IEC 61000-6-4; EN IEC 61326-1; EN IEC 61326-2-6; ETSI EN 301 489-1; ETSI EN 301 489-3

ETSI EN 301 489-3Name not checked yet
As written on the certificate · Line 7 (ENAC 827/LE1882)

EN IEC 61000-6-4; EN IEC 61326-1; EN IEC 61326-2-6; ETSI EN 301 489-1; ETSI EN 301 489-3

ETSI EN 301 489-17Name not checked yet
As written on the certificate · Line 8 (ENAC 827/LE1882)

ETSI EN 301 489-17; Reglamento ECE Nº 10; EN 55025; EN IEC 55025; CISPR 25; ISO 11452-2; ISO 11452-4; ISO 11452-5; ISO7637-2; ISO7637-3; ISO11452-8; ISO11452-9

IEC 61010 series

IEC 61010-1Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements
As written on the certificate · Line 10 (ENAC 827/LE1882)

IEC 61010-1; EN 61010-1; IEC 61010-2-081; EN 61010-2-081; IEC 61010-2-101; EN 61010-2-101; EN 60335-1

IEC 61010-2-081Name not checked yet
As written on the certificate · Line 10 (ENAC 827/LE1882)

IEC 61010-1; EN 61010-1; IEC 61010-2-081; EN 61010-2-081; IEC 61010-2-101; EN 61010-2-101; EN 60335-1

IEC 61010-2-101Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-101: Particular requirements for in vitro diagnostic (IVD) medical equipment
As written on the certificate · Line 10 (ENAC 827/LE1882)

IEC 61010-1; EN 61010-1; IEC 61010-2-081; EN 61010-2-081; IEC 61010-2-101; EN 61010-2-101; EN 60335-1

Other standards

FCC PART 15Radio Frequency Devices
As written on the certificate · Line 3 (ENAC 827/LE1882)

EN IEC 55015; EN IEC 61547; FCC CFR 47 Part 15; EN 55032; EN 55035

Scope as published by ENAC

12 lines
ENAC

ISO/IEC 17025

Active

827/LE1882

View scope

Location

Polígono Industrial Can Mitjans, s/n, Viladecavalls, 08232, ES

41.55640, 1.95532

Open in Maps

Accreditation data refreshed from the ENAC register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the ENAC entry linked above.