fzmb GmbH, Forschungszentrum für Medizintechnik und Biotechnologie Abteilung Lebensmitteluntersuchung
Geranienweg 7, 99947, Bad Langensalza, Germany
Free. We check which accredited labs can do it, starting with this one, and reply within two working days with who can do it, how fast, and roughly what it costs.
Only the laboratory you pick gets your contact details. We ask the others without them.
Contact this laboratory
Work at fzmb GmbH, Forschungszentrum für Medizintechnik und Biotechnologie Abteilung Lebensmitteluntersuchung?
Claim this profile to keep it accurate.
Register record
- DAKKSRefreshed
- D-PL-19238-01-00Active
- D-PL-19238-01-01Active
- D-PL-19238-01-02Active
Accredited standards
7Our reading of the DAKKS scope: each standard once, with its official name where we have checked it. Click a standard to see the scope line it comes from, word for word.
10113-2Name not checked yet
DIN 10113-1; DIN 10113-2; ASU L 00.00-20; ASU L 00.00-22; ASU L 00.00-32/1; ASU L 00.00-55
EN 150Name not checked yet
DIN EN ISO 19458; DIN EN ISO 9308-2; DIN EN ISO 7899-2; TrinkwV §43 Absatz (3); DIN EN 150 19458
ISO 7899-2Water quality - Detection and enumeration of intestinal enterococci - Part 2: Membrane filtration method
DIN EN ISO 19458; DIN EN ISO 9308-2; DIN EN ISO 7899-2; TrinkwV §43 Absatz (3); DIN EN 150 19458
DIN EN ISO 9308-2 2014-06; DIN EN ISO 7899-2 2000-11; TrinkwV §43 Absatz (3)
ISO 9308-2Water quality - Enumeration of Escherichia coli and coliform bacteria - Part 2: Most probable number method
DIN EN ISO 19458; DIN EN ISO 9308-2; DIN EN ISO 7899-2; TrinkwV §43 Absatz (3); DIN EN 150 19458
DIN EN ISO 9308-2 2014-06; DIN EN ISO 7899-2 2000-11; TrinkwV §43 Absatz (3)
ISO 11731Water quality - Enumeration of LegionellaCertificate says EN ISO 11731 2019-03 UBA Empfehlung 18. Probably the same standard; not checked against the EN document.
DIN EN ISO 11731 2019-03; UBA Empfehlung 18. Dezember 2018 Aktualisierung Dezember 2022 (Bundesgesundheitsblatt 2023 S. 224)
ISO 19458Water quality - Sampling for microbiological analysis
DIN EN ISO 19458; DIN EN ISO 9308-2; DIN EN ISO 7899-2; TrinkwV §43 Absatz (3); DIN EN 150 19458
TrinkwV §43 Absatz (3)Name not checked yet
DIN EN ISO 9308-2 2014-06; DIN EN ISO 7899-2 2000-11; TrinkwV §43 Absatz (3)
Scope as published by DAKKS
11 lines
ISO/IEC 17025
ActiveD-PL-19238-01-00
ISO/IEC 17025
ActiveD-PL-19238-01-01
ISO/IEC 17025
ActiveD-PL-19238-01-02
Location
Labs with overlapping accredited scope in Germany
- Limbach AnalyticsMannheim · ~237 kmDAKKSShares 7 accredited methods and materials10113-2EN ISO 19458EN ISO 9001
- Institut Dr. Nuss GmbH & Co. KGBad Kissingen · ~109 kmDAKKSShares 6 accredited methods and materialsEN ISO 19458EN ISO 9001TrinkwV §43 Absatz (3)
- Institut Dr. Nowak GmbH & Co. KGOttersberg · ~246 kmDAKKSShares 6 accredited methods and materials10113-2EN ISO 19458EN ISO 9001
- SGS Analytics GermanyFellbach · ~273 kmDAKKSShares 6 accredited methods and materials10113-2EN ISO 19458EN ISO 9001
- FSK Institut für Lebensmittelsicherheit und HygieneHerzogenrath · ~322 kmDAKKSShares 6 accredited methods and materials10113-2EN ISO 19458EN ISO 9001
Accreditation data refreshed from the DAKKS register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the DAKKS entry linked above.