United States

SIMCO Electronics - Memphis

7730B Trinity Road, Suite 130, 38018, Cordova, TN, United States

Visit website
A2LA 1395.21ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
6
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 6 scope lines.

A2LA certificate 1395.21 · 6 lines

LineMethodMatrixRange
1ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994-See scope document
2

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.21) 07/29/2025 Page 2 of 5 Parameter/Equipment Range CMC2, 3 (±) Comments DC Current – Measure (10 to 100) μA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A 25 μA/A + 0.8 nA 25 μA/A + 5 nA 25 μA/A + 50 nA 42 μA/A + 0.5 μA 0.016 % + 10 μA HP 3485A OPT-2 Resistance – Generate (0 to 11) Ω (11 to 33) Ω (33 to 110) Ω (110 to 330) Ω (0.33 to 1.1) kΩ (1.1 to 3.3) kΩ (3.3 to 11) kΩ (11 to 33) kΩ (33 to 110) kΩ (110 to 330) kΩ (0.33 to 1.1) MΩ (1.1 to 3.3) MΩ (3.3 to 11) MΩ (11 to 33) MΩ (33 to 110) MΩ (110 to 330) MΩ (0.11 to 1.1) GΩ 180 μΩ/Ω + 1 mΩ 63 μΩ/Ω + 1.5 mΩ 30 μΩ/Ω + 1.4 mΩ 26 μΩ/Ω + 2 mΩ 29 μΩ/Ω + 2 mΩ 26 μΩ/Ω + 0.02 Ω 26 μΩ/Ω + 0.02 Ω 27 μΩ/Ω + 0.2 Ω 26 μΩ/Ω + 0.2 Ω 41 μΩ/Ω + 2 Ω 34 μΩ/Ω + 2 Ω 49 μΩ/Ω + 30 Ω 0.013 % + 50 Ω 0.022 % + 2.5 kΩ 0.052 % + 3 kΩ 0.23 % + 0.1 MΩ 1.3 % + 0.5 MΩ Fluke 5522A/SC1100 Resistance – Measure 10 mΩ to 10 Ω (10 to 100) Ω (0.1 to 1) kΩ (1 to 10) kΩ (10 to 100) kΩ (0.1 to 1) MΩ (1 to 10) MΩ (10 to 100) MΩ 0.017 % + 1 mΩ 15 μΩ/Ω + 1.4 mΩ 12 μΩ/Ω + 2.0 mΩ 12 μΩ/Ω + 20 mΩ 12 μΩ/Ω + 0.2 Ω 19 μΩ/Ω + 2.0 Ω 63 μΩ/Ω + 50 Ω 0.06 % + 3 kΩ HP 3458A OPT-2
3--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.21) 07/29/2025 Page 3 of 5 Parameter/Range Frequency CMC2, 3 (±) Comments AC Current – Generate (30 to 330) μA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 1.1) A (1.1 to 11) A (11 to 20) A (30 to 330) μA (0.33 to 3.3) mA (3.3 to 33) mA (33 to 330) mA (0.33 to 1.1) A (1.1 to 11) A (11 to 20) A @ 1 kHz @ 5 kHz 0.12 % + 0.1 μA 0.079 % + 0.15 μA 0.033 % + 2 μA 0.035 % + 20 μA 0.040 % + 100 μA 0.040 % + 2 mA 0.12 % + 5 mA 0.24 % + 0.1 μA 0.16 % + 0.15 μA 0.064 % + 2 μA 0.079 % + 20 μA 0.47 % + 100 μA 0.25 % + 2 mA 2.4 % + 5 mA Fluke 5522A/SC1100 AC Current – Measure (5 to 100) μA (0.1 to 1) mA (1 to 10) mA (10 to 100) mA (0.1 to 1) A @ 1kHz 0.07 % + 0.03 μA 0.036 % + 0.2 μA 0.036 % + 2 μA 0.036 % + 20 μA 0.12 % + 0.2 mA HP 3458A OPT-2 AC Voltage – Generate (1 to 33) mV (33 to 330) mV (0.33 to 3.3) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz (100 to 500) kHz 0.063 % + 6 μV 0.017 % + 6 μV 0.02 % + 6 μV 0.08 % + 6 μV 0.28 % + 12 μV 0.63 % + 50 μV 0.024 % + 8 μV 0.012 % + 8 μV 0.013 % + 8 μV 0.028 % + 8 μV 0.063 % + 32 μV 0.16 % + 70 μV 0.023 % + 50 μV 0.012 % + 60 μV 0.015 % + 60 μV 0.024 % + 50 μV 0.055 % + 0.13 mV 0.19 % + 0.60 mV Fluke 5522A/SC1100
30 to 20 A
4--
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.21) 07/29/2025 Page 4 of 5 Parameter/Range Frequency CMC2, 3 (±) Comments AC Voltage – Generate (cont) (3.3 to 33) V (33 to 330) V (330 to 1020) V (10 to 45) Hz 45 Hz to 10 kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 10) kHz (10 to 20) kHz (20 to 50) kHz (50 to 100) kHz 45 Hz to 1 kHz (1 to 5) kHz (5 to 10) kHz 0.023 % + 0.65 mV 0.012 % + 0.6 mV 0.019 % + 0.6 mV 0.028 % + 0.6 mV 0.070 % + 1.6 mV 0.015 % + 2 mV 0.016 % + 6 mV 0.02 % + 6 mV 0.02 % + 6 mV 0.18 % + 50 mV 0.024 % + 10 mV 0.020 % + 10 mV 0.024 % + 10 mV Fluke 5522A/SC1100 AC Voltage – Measure (10 to 100) mV 100 mV to 1 V (1 to 10) V (10 to 100) V (100 to 700) V 40 Hz to 1 kHz (1 to 20) kHz (20 to 100) kHz (100 to 300) kHz (300 to 1000) kHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 100) kHz (100 to 300) kHz (300 to 1000) kHz (1 to 40) Hz 40 Hz to 1 kHz (1 to 20) kHz (20 to 100) kHz (100 to 300) kHz (300 to 1000) kHz 40 Hz to 1 kHz (1 to 20) kHz (20 to 100) kHz 40 Hz to 1 kHz 0.0095 % + 2 μV 0.018 % + 2 μV 0.099 % + 2 μV 0.11 % + 2 μV 0.11 % + 2 μV 0.009 % + 20 μV 0.017 % + 20 μV 0.093 % + 20 μV 0.093 % + 20 μV 0.093 % + 20 μV 0.010 % + 0.4 mV 0.010 % + 0.2 mV 0.017 % + 0.2 mV 0.093 % + 0.2 mV 0.093 % + 0.2 mV 0.093 % + 0.2 mV 0.024 % + 2 mV 0.025 % + 2 mV 0.14 % + 2 mV 0.047 % + 20 mV HP 3458A OPT-2 ____________________________________________ 1 This laboratory offers commercial service.
to 1020 V
5

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 1395.21) 07/29/2025 Page 5 of 5 2 Calibration and Measurement Capability Uncertainty (CMC) is the smallest uncertainty of measurement that a laboratory can achieve within its scope of accreditation when performing more or less routine calibrations of nearly ideal measurement standards or nearly ideal measuring equipment. CMCs represent expanded uncertainties expressed at approximately the 95 % level of confidence, usually using a coverage factor of k = 2. The actual measurement uncertainty of a specific calibration performed by the laboratory may be greater than the CMC due to the behavior of the customer’s device and to influences from the circumstances of the specific calibration. 3 The measurands stated are generated using the indicated instrument (see Comments). This capability is suitable for the calibration of the devices intended to measure the measurand in the ranges indicated. CMCs are expressed as either a specific value th at covers the full range or as a percent/fraction of the reading plus a fixed floor specification. 4 This scope meets A2LA’s P112 Flexible Scope Policy.
6ISO/IEC 17025:2017; ANSI/NCSL Z540-1-1994--

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

7730B Trinity Road, Suite 130, Cordova, TN, 38018, US

35.15565, -89.77620

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.