Eurofins Product Service (Thailand) Co.,
344/2 Soi Soonvijai 4, Rama 9 Rd., Huaykwang, Bangkapi, Bangkok, 10320, Thailand, Bangkok, Thailand
Visit website- Accredited standards
- 131
- A2LA certificates
- 2
- Site in our directory
- 1
What this lab is accredited for
Our reading of the A2LA scope: each standard once, with its official name where we have checked it.
Only this lab. Searches the 131 standard numbers and the 29 official names we hold. When no standard matches, it searches the method text of every scope line.
IEC 60335 series37
IEC 60335-1Household and similar electrical appliances - Safety - Part 1: General requirements+1 national
National versions in the same scope
AS/NZS 60335.1national version with changes
IEC 60335-2-2Household and similar electrical appliances - Safety - Part 2-2: Particular requirements for vacuum cleaners and water-suction cleaning appliances
IEC 60335-2-3Household and similar electrical appliances - Safety - Part 2-3: Particular requirements for electric irons
IEC 60335-2-4+1 national
National versions in the same scope
AS/NZS 60335.2.4probably the same standard; matched by number only
IEC 60335-2-5
IEC 60335-2-6
IEC 60335-2-7+1 national
National versions in the same scope
AS/NZS 60335.2.7probably the same standard; matched by number only
IEC 60335-2-8Household and similar electrical appliances - Safety - Part 2-8: Particular requirements for shavers, hair clippers and similar appliances
IEC 60335-2-9Household and similar electrical appliances - Safety - Part 2-9: Particular requirements for grills, toasters and similar portable cooking appliances
IEC 60335-2-11+1 national
National versions in the same scope
AS/NZS 60335.2.11probably the same standard; matched by number only
IEC 60335-2-12Household and similar electrical appliances - Safety - Part 2-12: Particular requirements for warming plates and similar appliances
IEC 60335-2-13Household and similar electrical appliances - Safety - Part 2-13: Particular requirements for deep fat fryers, frying pans and similar appliances
Show all 37
IEC 60335-2-14
IEC 60335-2-15
IEC 60335-2-17
IEC 60335-2-21
IEC 60335-2-23
IEC 60335-2-24+1 national
National versions in the same scope
AS/NZS 60335.2.24probably the same standard; matched by number only
IEC 60335-2-26
IEC 60335-2-29
IEC 60335-2-41+1 national
National versions in the same scope
AS/NZS 60335.2.41probably the same standard; matched by number only
IEC 60335-2-44
IEC 60335-2-52
IEC 60335-2-54
IEC 60335-2-59
IEC 60335-2-65
IEC 60335-2-74
IEC 60335-2-75
IEC 60335-2-78
IEC 60335-2-80
IEC 60335-2-81
IEC 60335-2-84
IEC 60335-2-88
IEC 60335-2-89
IEC 60335-2-98
IEC 60335-2-101
IEC 60335-2-116+1 national
National versions in the same scope
AS/NZS 60335.2.116probably the same standard; matched by number only
IEC 60704 series20
IEC 60704-1
IEC 60704-2-1
IEC 60704-2-2
IEC 60704-2-3
IEC 60704-2-4
IEC 60704-2-5
IEC 60704-2-6
IEC 60704-2-7
IEC 60704-2-8
IEC 60704-2-9
IEC 60704-2-10
IEC 60704-2-11
Show all 20
IEC 60704-2-13
IEC 60704-2-14
IEC 60704-2-16
IEC 60704-2-17
IEC 60704-2-18
IEC 60704-2-19
IEC 60704-2-20
IEC 60704-3
IEC19
IEC 60065-1
IEC 60068-2-75
IEC 60107-1
IEC 60112
IEC 60456
IEC 60529Degrees of protection provided by enclosures (IP Code)
IEC 60705
IEC 60879
IEC 60950-1Information technology equipment - Safety - Part 1: General requirements
IEC 61121
IEC 61199
IEC 62031
Show all 19
IEC 62087-1
IEC 62262
IEC 62301
IEC 62368-1Audio/video, information and communication technology equipment - Part 1: Safety requirements
IEC 62512
IEC 62560
IEC 62776
IEC 60598 series14
IEC 60598-1Luminaires - Part 1: General requirements and tests
IEC 60598-2-1
IEC 60598-2-2
IEC 60598-2-3
IEC 60598-2-4
IEC 60598-2-5
IEC 60598-2-7
IEC 60598-2-8
IEC 60598-2-10
IEC 60598-2-17
IEC 60598-2-20
IEC 60598-2-22
IEC 60598-2-23
IEC 60598-2-24
IEC 61558 series8
IEC 61558-1
IEC 61558-2-1
IEC 61558-2-2
IEC 61558-2-4
IEC 61558-2-6
IEC 61558-2-8
IEC 61558-2-9
IEC 61558-2-12
CISPR6
CISPR 11Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS CISPR 11national version with changes
CISPR 13Sound and television broadcast receivers and associated equipment - Radio disturbance characteristics - Limits and methods of measurement
CISPR 14-1Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission+2 national
National versions in the same scope
AS CISPR 14.1national version with changes
AS/NZS CISPR 14.1national version with changes
CISPR 15Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment+2 national
National versions in the same scope
AS CISPR 15national version with changes
AS/NZS CISPR 15national version with changes
CISPR 22Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement+1 national
National versions in the same scope
AS/NZS CISPR 22identical to it
CISPR 32Electromagnetic compatibility of multimedia equipment - Emission requirements+1 national
National versions in the same scope
AS/NZS CISPR 32identical to it
IEC 60695 series6
IEC 60695-2-11
IEC 60695-2-12
IEC 60695-2-13
IEC 60695-10-2Fire hazard testing - Part 10-2: Abnormal heat - Ball pressure test method
IEC 60695-11-5
IEC 60695-11-10
IEC 61000 series4
IEC 61000-3-2Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)+1 national
National versions in the same scope
AS/NZS 61000.3.2identical to it
IEC 61000-3-3Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection+1 national
National versions in the same scope
AS/NZS 61000.3.3identical to it
IEC 61000-3-11Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current ≤ 75 A and subject to conditional connection
IEC 61000-3-12Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current >16 A and ≤ 75 A per phase
IEC 61347 series4
IEC 61347-1
IEC 61347-2-1
IEC 61347-2-3
IEC 61347-2-13
ISO 10472 series4
ISO 10472-1Safety requirements for industrial laundry machinery - Part 1: Common requirements
ISO 10472-2Safety requirements for industrial laundry machinery - Part 2: Washing machines and washer-extractors
ISO 10472-4Safety requirements for industrial laundry machinery - Part 4: Air dryers
ISO 10472-5Safety requirements for industrial laundry machinery - Part 5: Flatwork ironers, feeders and folders
EN3
EN 50229
EN 50561-1
EN 50564
IEC 60432 series3
IEC 60432-1
IEC 60432-2
IEC 60432-3
Other standards3
ANSI C63.4American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ISO 3744Acoustics - Determination of sound power levels of noise sources using sound pressure - Engineering methods for an essentially free field over a reflecting plane
ISO 3745Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Precision methods for anechoic rooms and hemi-anechoic rooms
IEC 60335-1; EN 60335-1; EN IEC 60335-1; UL 60335-1; IEC 60335-1 Ed. 5.2; IEC 60335-1:2001; PNS IEC 60335-1:2011; ISO 10472-1; AS/NZS 60335.1; IEC 60335-2-2; EN 60335-2-2; EN IEC 60335-2-2; IEC 60335-2-3; EN 60335-2-3; IEC 60335-2-4; EN 60335-2-4; EN IEC 60335-2-4; UL 2157; IEC 60335-2-4:2003; PNS IEC 60335-2-4:2018; AS/NZS 60335.2.4; IEC 60335-2-5; EN 60335-2-5; IEC 60335-2-6; EN 60335-2-6; IEC 60335-2-7; EN 60335-2-7; EN IEC 60335-2-7; UL 2157; IEC 60335-2-7:2002; PNS IEC 60335-2-7:2021; ISO 10472-2; AS/NZS 60335.2.7; IEC 60335-2-8; EN 60335-2-8; IEC 60335-2-9; EN 60335-2-9; EN IEC 60335-2-9; IEC 60335-2-11; EN 60335-2-11; EN IEC 60335-2-11; ISO 10472-4; AS/NZS 60335.2.11; IEC 60335-2-12; EN 60335-2-12; IEC 60335-2-13; EN 60335-2-13; IEC 60335-2-14; EN 60335-2-14; EN IEC 60335-2-14; IEC 60335-2-15; EN 60335-2-15; IEC 60335-2-17; EN 60335-2-17; IEC 60335-2-21; EN 60335-2-21; IEC 60335-2-23; EN 60335-2-23; EN IEC 60335-2-23; IEC 60335-2-24; EN 60335-2-24; EN IEC 60335-2-24; UL 60335-2-24; IEC 60335-2-24:2002; PNS IEC 60335-2-24:2018; AS/NZS 60335.2.24; IEC 60335-2-26; EN 60335-2-26; IEC 60335-2-29; EN 60335-2-29
IEC 60335-2-41; EN 60335-2-41; EN IEC 60335-2-41; AS/NZS 60335.2.41; IEC 60335-2-44; EN 60335-2-44; ISO 10472-5; IEC 60335-2-52; EN 60335-2-52; IEC 60335-2-54; EN 60335-2-54; IEC 60335-2-59; EN 60335-2-59; IEC 60335-2-65; EN 60335-2-65; IEC 60335-2-74; EN 60335-2-74; IEC 60335-2-75; EN 60335-2-75; EN IEC 60335-2-75; IEC 60335-2-78; EN 60335-2-78; IEC 60335-2-80; EN 60335-2-80; EN IEC 60335-2-80; IEC 60335-2-81; EN 60335-2-81; EN IEC 60335-2-81; IEC 60335-2-84; EN 60335-2-84; EN IEC 60335-2-84; IEC 60335-2-88; EN 60335-2-88; IEC 60335-2-89; EN 60335-2-89; EN IEC 60335-2-89; UL 60335-2-89; IEC 60335-2-98; EN 60335-2-98; IEC 60335-2-101; EN 60335-2-101; IEC 60335-2-116; EN IEC 60335-2-116; AS/NZS 60335.2.116; IEC 60598-1; EN 60598-1; EN IEC 60598-1; IEC 60598-1 Ed. 8.1; IEC 60598-2-1; EN 60598-2-1; EN IEC 60598-2-1; IEC 60598-2-2; EN 60598-2-2; EN IEC 60598-2-2; IEC 60598-2-3; EN 60598-2-3; IEC 60598-2-4; EN 60598-2-4; IEC 60598-2-5; EN 60598-2-5; IEC 60598-2-7; IEC 60598-2-8; EN 60598-2-8; IEC 60598-2-10; EN 60598-2-10; IEC 60598-2-17; EN 60598-2-17; EN IEC 60598-2-17; IEC 60598-2-20; EN 60598-2-20; EN IEC 60598-2-20; IEC 60598-2-22; EN 60598-2-22; EN IEC 60598-2-22
IEC 60529; EN 60529; IEC 62262; EN 62262; IEC 60068-2-75; EN 60068-2-75; IEC 60695-2-11; EN 60695-2-11; EN IEC 60695-2-11; IEC 60695-2-12; EN 60695-2-12; EN IEC 60695-2-12; IEC 60695-2-13; EN 60695-2-13; EN IEC 60695-2-13; IEC 60695-10-2; EN 60695-10-2; IEC 60695-11-5; EN 60695-11-5; IEC 60695-11-10; EN 60695-11-10; IEC 60112; EN 60112; EN IEC 60112; IEC 60704-1; EN 60704-1; EN IEC 60704-1; IEC 60704-1 Ed. 3.0; GB/T 4214.1; IEC 60704-2-1; EN 60704-2-1; EN IEC 60704-2-1
IEC 60704-2-2; EN 60704-2-2; EN IEC 60704-2-2; IEC 60704-2-3; EN 60704-2-3; IEC 60704-2-4; EN 60704-2-4; IEC 60704-2-5; EN 60704-2-5; IEC 60704-2-6; EN 60704-2-6; IEC 60704-2-7; EN 60704-2-7; EN IEC 60704-2-7; IEC 60704-2-8; EN 60704-2-8; EN IEC 60704-2-8; IEC 60704-2-9; EN 60704-2-9; EN IEC 60704-2-9; GB/T 4214.6; IEC 60704-2-10; EN 60704-2-10; EN IEC 60704-2-10; IEC 60704-2-11; EN 60704-2-11; EN IEC 60704-2-11; IEC 60704-2-13; EN 60704-2-13; EN IEC 60704-2-13; IEC 60704-2-14; EN 60704-2-14; IEC 60704-2-16; EN IEC 60704-2-16; IEC 60704-2-17; EN IEC 60704-2-17; IEC 60704-2-18; EN IEC 60704-2-18; IEC 60704-2-19; EN IEC 60704-2-19; IEC 60704-2-20; EN IEC 60704-2-20; IEC 60704-3; EN 60704-3; GB/T 19606; ISO 3744; ISO 3745
IEC 60598-2-23; EN 60598-2-23; EN IEC 60598-2-23; IEC 60598-2-24; EN 60598-2-24; EN IEC 60598-2-24; IEC 62031; EN 62031; EN IEC 62031; IEC 61199; EN 61199; IEC 61347-1; EN 61347-1; EN IEC 61347-1; IEC 61347-2-1; EN 61347-2-1; EN IEC 61347-2-1; IEC 61347-2-3; EN 61347-2-3; EN IEC 61347-2-3; IEC 61347-2-13; EN 61347-2-13; EN IEC 61347-2-13; IEC 60432-1; EN 60432-1; IEC 60432-2; EN 60432-2; IEC 60432-3; EN 60432-3; IEC 62560; EN 62560; IEC 62776; EN 62776; EN IEC 62776; IEC 60065; EN 60065; IEC 60950-1; EN 60950-1; IEC 62368-1; EN IEC 62368-1; UL 62368-1; IEC 61558-1; EN 61558-1; EN IEC 61558-1; IEC 61558-2-1; EN 61558-2-1; EN IEC 61558-2-1; IEC 61558-2-2; EN 61558-2-2; EN IEC 61558-2-2; IEC 61558-2-4; EN 61558-2-4; EN IEC 61558-2-4; IEC 61558-2-6; EN 61558-2-6; EN IEC 61558-2-6; IEC 61558-2-8; EN 61558-2-8; EN IEC 61558-2-8; IEC 61558-2-9; EN 61558-2-9; EN IEC 61558-2-9; IEC 61558-2-12; EN 61558-2-12; EN IEC 61558-2-12
PNS 396-3:2013; SPAN TS 3006:2021; AS/NZS 2040.1; AS/NZS 2040.2; UAE.S.5010-2; UAE.S IEC 60456; JS 1717 (2006); JS 1888 (2012); JS 2103; JS 2104; 10 CFR 430, Subpart B, Appendix J; AHAM HLW-1-2010; AHAM HLW-2-2020; IEC 61121:2005; IEC 61121; EN 61121; UAE.S IEC 61121; IEC 62512; EN IEC 62512; UAE.S IEC 62512; EN 50229; AS/NZS 2442.1; AS/NZS 2442.2; IEC 61121:2012; IEC 60107-1; EN 60107-1; IEC 60705; EN 60705; EN IEC 60705; IEC 60879; EN 60879; IEC 62301; EN 62301; EN 62087; EN 50564
IEC 61121:2012; IEC 60107-1; EN 60107-1; IEC 60705; EN 60705; EN IEC 60705; IEC 60879; EN 60879; IEC 62301; EN 62301; EN 62087; EN 50564; 47 Code of Federal Regulations; FCC KDB 974614, Appendix A, Table A.1; ANSI C63.4:2014; FCC MP-5:1986
ANSI C63.4-2014; MP-5:1986; CISPR 11; EN 55011; EN IEC 55011; AS CISPR 11; J55011 (H27); CISPR 13; EN 55013; J55013 (H22); CISPR 14-1:2016; CISPR 14-1; AS/NZS CISPR 14.1; AS CISPR 14.1; EN 55014-1; EN IEC 55014-1; TCVN 7492-1; J55014-1(H27); GSO CISPR 14-1; CISPR 15; AS/NZS CISPR 15; AS CISPR 15; EN 55015; EN IEC 55015; J55015 (H20); CISPR 22; AS/NZS CISPR 22; EN 55022; J55022 (H22); CISPR 32; EN 55032; AS/NZS CISPR 32; EN 50561-1; IEC 61000-3-2; EN 61000-3-2; EN IEC 61000-3-2; AS/NZS 61000.3.2; GSO IEC 61000-3-2; EN 61000-3-12; IEC 61000-3-12; IEC 61000-3-3; EN 61000-3-3; AS/NZS 61000.3.3; GSO IEC 61000-3-3; EN 61000-3-11; EN IEC 61000-3-11; IEC 61000-3-11
ANSI C63.4-2014; MP-5:1986; CISPR 11; EN 55011; EN IEC 55011; AS CISPR 11; J55011 (H27); CISPR 13; EN 55013; J55013 (H22); CISPR 14-1:2016; CISPR 14-1; AS/NZS CISPR 14.1; AS CISPR 14.1; EN 55014-1; EN IEC 55014-1; TCVN 7492-1; J55014-1(H27); GSO CISPR 14-1; CISPR 15; AS/NZS CISPR 15; AS CISPR 15; EN 55015; EN IEC 55015; J55015 (H20); CISPR 22; AS/NZS CISPR 22; EN 55022; J55022 (H22); CISPR 32; EN 55032; AS/NZS CISPR 32; EN 50561-1; IEC 61000-3-2; EN 61000-3-2; EN IEC 61000-3-2
Read from the A2LA scope documents we downloaded on 2026-10-27. Register refreshed 2026-11-20.
Scope as published by A2LA
15 lines
ISO/IEC 17025
Active2402.01
The scope document we hold says it is valid until 2027-12-31.
ISO/IEC 17025
Active2402.02
The scope document we hold says it is valid until 2027-12-31.
Location
344/2 Soi Soonvijai 4, Rama 9 Rd., Huaykwang, Bangkapi, Bangkok, 10320, Thailand, Bangkok, TH
13.75249, 100.49351
Open in MapsAccreditation data refreshed from the A2LA register on .
This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.