Registers refreshed 2026-11-20.See refresh dates
United States

Heartland Assays

2711 South Loop Drive, Suite 4400, 50010, Ames, IA, United States

Visit website
A2LA 3969.01ISO/IEC 17025Register refreshed 2026-11-20

We check which accredited labs can do it, starting with this one, and send you a short comparison of time and rough cost within three working days.

  • Free, no obligation.
Scope lines
2
A2LA certificate
1
Site in our directory
1
A2LA accredited scope

What this lab is accredited for

We found no published test standard numbers in this lab’s scope. The full scope as published is below.

Only this lab. Searches the method, matrix and range of each of the 2 scope lines.

A2LA certificate 3969.01 · 2 lines

LineMethodMatrixRange
1-Serum
Show page text

Extracted from the scope document; tables may not line up. View scope for the original.

(A2LA Cert. No. 3969.01) 12/09/2025 Page 1 of 1 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 HEARTLAND ASSAYS, LLC 2711 South Loop Drive, Suite 4400 Ames, IA 50010 Dr. John Rathmacher Phone: 515 296 4169 CHEMICAL Valid To: January 31, 2028 Certificate Number: 3969.01 In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this laboratory to perform the following tests on human and animal specimens, plasma, serum, urine, food, mushrooms, supplements, extracts, and feed/premix, and hemp plant material: Test Matrices In-House Method β-Hydroxy-β-methylbutyrate (HMB) Analysis using Gas Chromatography/Mass Spectrometry Plasma Serum Urine Internal Procedure P-110 HMB Cannabinoids using High Pressure Liquid Chromatography CBD- Cannabidiol CBN- Cannabinol CBDA- Cannabidolic Acid THCA-A- Tetrahydrocannabinolic Acid A ∆8-THC- delta-8-tetrahydrocannabinol ∆9-THC- delta-9-tetrahydrocannabinol Extracts Hemp Plant Material Supplements Internal Procedure P-168 Cannabinoids in Complex Matrices Vitamin D and 25(OH)-Vitamin D in Complex Matrices using High Pressure Liquid Chromatography Feed/Premix Food Mushrooms Supplements Internal Procedure P-144 Vitamin D in Complex Matrices Vitamin D and 25(OH)-Vitamin D in Complex Matrices using Liquid Chromatography/Mass Spectrometry Feed/Premix Food Supplements Tissue Internal Procedure P-130 Vitamin D in Complex Matrices via LCMS
-
2

Extracted from the scope document; tables may not line up. View scope for the original.

For the tests to which this accreditation applies, please refer to the laboratory’s Chemical Scope of Accreditation. Accredited Laboratory A2LA has accredited HEARTLAND ASSAYS, LLC Ames, IA for technical competence in the field of Chemical Testing This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated April 2017). Presented this10th day of December 2025. _______________________ Mr. Trace McInturff, Vice President, Accreditation Services For the Accreditation Council Certificate Number 3969.01 Valid to January 31, 2028

Ranges are reproduced from the accredited scope document as published, and only where we found that range printed in the document for the line. Otherwise the cell reads “See scope document”. An absent range means the register did not state one. Line numbers are ours, for cross-reference; they follow the order of the scope document.

Location

2711 South Loop Drive, Suite 4400, Ames, IA, 50010, US

42.02676, -93.61704

Open in Maps

Accreditation data refreshed from the A2LA register on .

This page mirrors a public register. For a purchasing, audit or regulatory decision, confirm against the A2LA entry linked above.